Sign In | Join Free | My frbiz.com |
|
Categories | Transformer Oil Purifier Machine |
---|---|
Brand Name: | REXON |
Model Number: | ZYD-200(12000LPH) |
Certification: | CE, ISO, SGS, CCC |
Place of Origin: | China |
MOQ: | 1 Set |
Price: | Negotiation |
Payment Terms: | T/T, L/C, Western Union |
Supply Ability: | 500Sets per Month |
Delivery Time: | 3~10 working days basd on model |
Packaging Details: | Standard wooden cases |
Function: | Transformer Oil Filtration, Purification, Maintenance |
Process Capacity: | 12,000Liters/Hour |
Power Supply: | 380V, 3Phase, 50HZ or as required |
Color: | Green, Blue, Grey, White, Yellow Etc. |
Work Principle 01: | Automatic Foaming Elimination |
Work Principle 02: | Vacuum Oil Dehydration |
Work Principle 03: | Multi-Stage Oil Filtering |
Work Principle 04: | Thermostatically Heating |
Fully Enclosed Type Bipolar Vacuum Insulation Oil Purification System 12000Liters/Hour
Transformer oil treatment plant means?
Old transformer oil is generally mixed with gas, water and
contaminants, and also the new transformer oil sometimes, the
content of the contaminants generally increases fast by time. So
the transformer oil treatment machines can remove these associated
gases, water and contaminants, and separate them from the oil and
take them away. After treating the oil by our oil treatment plant,
the stabilized oil is then again ready to be used in power
transformers.
Transformer oil purifier ZYD brings?
Series ZYD Double-stage vacuum transformer oil purifier can remove
the water, gas and impurities in insulation oil high-efficiently,
increasing the pressure force and quality of oil, make the oil
limiting voltage-withstand value much higher and make sure the
electric device running safely. The machine is mainly used for
electric power department and industries to deal with various oils
such as transformer oil, mutual oil, switch oil, dielectric oil and
so on. It also can be used for filtration of more than 110KV
substation live line work onsite. Meanwhile, as the bridge-type
vacuum linking system, Series ZYD oil purifier can be used as
independent vacuum source with functions of vacuum drying and
vacuum oiling.
Advantage:
Fully Enclosed Type Bipolar Vacuum Insulation Oil Purification System 12000Liters/Hour, High Voltage Transformer Oil Purifier Machine Model ZYD is particularly suitable for filtering high-grade transformer oil, super-voltage transformer oil and new transformer oil. It can be used for filtration of more than 110V substation live line work onsite.
Application:
Fully Enclosed Type Bipolar Vacuum Insulation Oil Purification System 12000Liters/Hour, High Voltage Transformer Oil Purifier Machine Model ZYD is mainly used for removing trace water, gas and impurities from insulating oil, improving the insulating oil performance index. It is mainly applied to purification for high voltage insulating oil of 110KV,220KV,500KV,750KV,1000KV from power transmission equipment.
Feature:
1. Especially for removing water from transformer oil, such as free water, trace water and so on by the double stage vacuum system for high voltage oil.
2. Remove gas, air content from the old high voltage transformer oil by vacuum degassing system.
3. Remove impurities, tiny particles, acidity, sludge, free carbon, other soluble oil decay products and discoloration substances by 3 stages of filters (Primary filter, secondary filter, fine filter).
4. Independent vacuum oiling system for transformers, this oil purifier can also vacuum dry transformer and on-line operation with transformers.
5. Designed for processing high voltage insulating oils in workshops, onsite power stations, purifying oil in oil storage tanks or directly in transformers(energized or de-energized transformers).
6. Efficient electric heating system, heating uniformity, less
power consumption, safe, and reliable.
7. Double-infrared liquid level sensor, pressure protective system
and foaming detecting and eliminating to ensure machine operation
easily and safely.
8.Adopt interlocked protective system, which connect oil pump, heater and liquid level sensor, avoiding blank heating, blank pumping.
Technical Parameters:
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working Vacuum | Mpa | -0.08 ~-0.099 | |||||||
Working Pressure | Mpa | ≤ 0.3 | |||||||
Temp Range | ℃ | 20 ~80 | |||||||
Power Supply | 380V, 50Hz, 3Phase( As per required) | ||||||||
Working Noise | Db | 60 - 80 (Depended on the configuation) | |||||||
Heating Power | KW | 30 | 60 | 90 | 135 | 150 | 165 | 180 | |
Total Power | KW | 35 | 67.5 | 101.5 | 149 | 164 | 198 | ||
Inlet/Outlet Diam | MM | 25 | 32 | 42 | 50 | 50 | 60 | 60 | |
Weight | KG | 450 | 550 | 750 | 950 | 1200 | 1850 | 2000 | |
Size | Length | MM | 1450 | 1450 | 1750 | 1850 | 1950 | 2050 | 2150 |
Width | MM | 950 | 1000 | 1250 | 1300 | 1350 | 1400 | 1450 | |
Height | MM | 1700 | 1750 | 1950 | 2000 | 2050 | 2100 | 2150 | |
AFTER TREATMENT | |||||||||
Dielectric Strength | KV | ≥ 75-85 | |||||||
Water Content | PPM | ≤ 3 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Particle Size | μ | ≤ 3 | |||||||
Cleanliness ≤NAS 1638 Grade 5 |
The oil technical data after treatment:
1. Gas content is less than 0.1%
2. Impurity size is less than 1μm without free carbon
3. Water content is less than 3 part per million
3. Oil dielectric strength (breakdown voltage) is more than 75KV
4. Acidity value is less than 0.01 mg KOH/g
5. Dielectric loss factors at 90℃ is less than 0.001
(oil filtration, oil purification, oil treatment, oil purifier, oil recycling, oil processing, oil filtering, oil filtration, energy saving, oil regeneration, oil processor, oil filter, oil process, oil purify, oil regenerating, oil restoration, waste oil disposal, oil reclaimed, oil reclaiming, waste oil management, oil regenerate, oil reconditioned, oil reconstituted, oil restituting, oil recovering, oil recondition, oil filters, oil refinery, oil refiner, oil cleaning, oil recycle, oil reclaiming, oil separator, oil recovery, oil recycle, oil reclamation, oil refinery, oil separator, oil separation, oil purifiers, oil recondition )
REXON high vacuum dehydration transformer oil filtration machine is used to deal with unqualified transformer oil, Insulation oil, insulating oil, switch oil and so on with big treatment capacity like 9,000L/H, 12,000L/H, 18,000L/H, 30,000L/H etc. Contaminated transformer oil, after being treated by our oil filter system, can meet the qualified indicators, just like the new oil that has not been polluted, can be reapplied to the transformer.
![]() |