Sign In | Join Free | My frbiz.com |
|
Categories | Transformer Oil Purifier Machine |
---|---|
Brand Name: | REXON |
Model Number: | ZYD-150(9000LPH) |
Certification: | CE, ISO, SGS, CCC |
Place of Origin: | China |
MOQ: | 1 Set |
Price: | Negotiation |
Payment Terms: | T/T, L/C, Western Union |
Supply Ability: | 500Sets per Month |
Delivery Time: | 3~10 working days basd on model |
Packaging Details: | Standard wooden cases |
Function: | Transformer Oil Filtration, Purification, Maintenance |
Process Capacity: | 9000Liters/Hour |
Power Supply: | 380V, 3Phase, 50HZ or as required |
Color: | Green, Blue, Grey, White, Yellow Etc. |
Work Principle 01: | Automatic Foaming Elimination |
Work Principle 02: | Vacuum Oil Dehydration |
Work Principle 03: | Multi-Stage Oil Filtering |
Work Principle 04: | Thermostatically Heating |
Fully Enclosed Type High Vacuum Dehydration Transformer Oil Purifier Machine 9000LPH
Transformer oil purifier ZYD brings?
Series ZYD Double-stage vacuum transformer oil purifier can remove
the water, gas and impurities in insulation oil high-efficiently,
increasing the pressure force and quality of oil, make the oil
limiting voltage-withstand value much higher and make sure the
electric device running safely. The machine is mainly used for
electric power department and industries to deal with various oils
such as transformer oil, mutual oil, switch oil, dielectric oil and
so on. It also can be used for filtration of more than 110KV
substation live line work onsite. Meanwhile, as the bridge-type
vacuum linking system, Series ZYD oil purifier can be used as
independent vacuum source with functions of vacuum drying and
vacuum oiling.
Application:
Fully Enclosed Type High Vacuum Dehydration Transformer Oil Purifier Machine 9000LPH,High Voltage Transformer Oil Purifier Machine Model ZYD is mainly used for removing trace water, gas and impurities from insulating oil, improving the insulating oil performance index. It is mainly applied to purification for high voltage insulating oil of 110KV,220KV,500KV,750KV,1000KV from power transmission equipment.
Feature:
1. Especially for removing water from transformer oil, such as free water, trace water and so on by the double stage vacuum system for high voltage oil.
2. Remove gas, air content from the old high voltage transformer oil by vacuum degassing system.
3. Remove impurities, tiny particles, acidity, sludge, free carbon, other soluble oil decay products and discoloration substances by 3 stages of filters (Primary filter, secondary filter, fine filter).
4. Independent vacuum oiling system for transformers, this oil purifier can also vacuum dry transformer and on-line operation with transformers.
5. Designed for processing high voltage insulating oils in workshops, onsite power stations, purifying oil in oil storage tanks or directly in transformers(energized or de-energized transformers).
6. Efficient electric heating system, heating uniformity, less
power consumption, safe, and reliable.
7. Double-infrared liquid level sensor, pressure protective system
and foaming detecting and eliminating to ensure machine operation
easily and safely.
8.Adopt interlocked protective system, which connect oil pump, heater and liquid level sensor, avoiding blank heating, blank pumping.
Advantage:
Fully Enclosed Type High Vacuum Dehydration Transformer Oil Purifier Machine 9000LPH,High Voltage Transformer Oil Purifier Machine Model ZYD is particularly suitable for filtering high-grade transformer oil, super-voltage transformer oil and new transformer oil. It can be used for filtration of more than 110V substation live line work onsite.
Technical Parameters:
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working Vacuum | Mpa | -0.08 ~-0.099 | |||||||
Working Pressure | Mpa | ≤ 0.3 | |||||||
Temp Range | ℃ | 20 ~80 | |||||||
Power Supply | 380V, 50Hz, 3Phase( As per required) | ||||||||
Working Noise | Db | 60 - 80 (Depended on the configuation) | |||||||
Heating Power | KW | 30 | 60 | 90 | 135 | 150 | 165 | 180 | |
Total Power | KW | 35 | 67.5 | 101.5 | 149 | 164 | 198 | ||
Inlet/Outlet Diam | MM | 25 | 32 | 42 | 50 | 50 | 60 | 60 | |
Weight | KG | 450 | 550 | 750 | 950 | 1200 | 1850 | 2000 | |
Size | Length | MM | 1450 | 1450 | 1750 | 1850 | 1950 | 2050 | 2150 |
Width | MM | 950 | 1000 | 1250 | 1300 | 1350 | 1400 | 1450 | |
Height | MM | 1700 | 1750 | 1950 | 2000 | 2050 | 2100 | 2150 | |
AFTER TREATMENT | |||||||||
Dielectric Strength | KV | ≥ 75-85 | |||||||
Water Content | PPM | ≤ 3 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Particle Size | μ | ≤ 3 | |||||||
Cleanliness ≤NAS 1638 Grade 5 |
REXON high vacuum dehydration transformer oil filtration machine
adopts two-stage high vacuum system, high efficiency three-stage
filter system, high-power low-temperature heating system, constant
temperature heating control system, intelligent electronic control
system, PLC control system, automatic oil level The detection
system, the vacuum detection system, and the safety protection
system, etc., REXON machines are constructed using the latest oil
filtering technology and internationally renowned brand
accessories.
![]() |