Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home > Other Machinery & Industry Equipment >

Self Regulating Electric Heat Tracing For Chemical Plant

Categories Electric Heat Tracing
Brand Name: MICH
Model Number: EHTTSCP
Certification: ISO9001
Place of Origin: China
MOQ: 1 meter
Price: USD0.5-USD5 per meter
Supply Ability: 10 million meters per year
Delivery Time: in one month
Packaging Details: plywood crates
Dimensions: 0.2"x0.3" (5mm x 8mm) 12 AWG
Dielectric Strength: Over 2000 volts
Property: As per project application
Usage: Chemical Plant
Flame Resistance: Good
Wattage: 39Watt/meter
Max. Exposure Temp. (°F) Power Off: 260
Voltages: Up to 480
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Self Regulating Electric Heat Tracing For Chemical Plant

Electric Heat Tracing Technical Solution for Chemical Plant is a package solution for the industrial processes to manufacture chemical product either in large scaled production or fine chemical production.



Electric Heat Tracing Technical Solution for Chemical Plant guarantees the maintenance of the temperature in the pipes, tanks and process equipment. That maintenance prevents any problem derived from losing temperature in processes: obstructions and breakages, increased viscosity in fluids, condensation of water steam in gases and phase shifts...


The solution normally uses parallel type heating cables (Self-regulating and/or Constant Power) and temperature control adapted to each process. All commanded by direct temperature and power control panels.


Here are five applications typically:


1. High Temperature Heat Tracing: for the use of temperature higher than 500°C
2. Long-Line Heating: for the use of pipeline more than 300 meters.

3. Freeze Protection: The main purpose of a freeze-protection system is to prevent fluids such as process water, drain water and fire water lines from freezing in pipes.
4. Process Temperature Maintenance without Steam Exposure: With process temperature-maintenance applications, there is usually a need for viscosity control of certain fluids such as fuel oils, acids and fertilizers at higher temperatures beyond freeze-protection applications.
5. Process Temperature Maintenance with Steam Exposure: In some freeze-protection and process temperature-maintenance applications, the heat-tracing cable is exposed to higher temperatures than the maintenance temperature when steam is used to clean the pipes.


Table 2 Heating Cable Specification (600V Single Conductor)


Cable CodeDiameterHDPE DiameterStandard resistance value at +20Maximum Production LengthUnit weight
mmmmΩ/mmkg/km
16C1.78.2100.0017350366.54
16C2.27.69.40.0022380307.77
16C2.97.08.80.0029400264.45
16C45.97.70.004600190.88
16C75.37.10.007600154.08
16C114.96.70.011600132.25
16C134.66.40.013600 (300)☆125.7
16C174.66.40.017600 (300)☆117.16
16C214.66.40.021600 (300)☆111.9
16C253.75.50.025600 (480)☆68.83
16C333.75.50.033600 (480)☆63.76
16C403.45.20.04600 (560)☆58.87
16C633.250.06360051.47
16K806.88.60.08370 (140)☆254.18
16K1005.270.1450 (240)☆162.11
16K1404.96.70.14600 (270)☆122.55
16K1974.456.250.197600 (330)☆111.32
16K2204.56.30.22600 (330)☆102.89
16K3154.36.10.315600 (350)☆91.44
16K3454.26.00.345600 (370)☆85.9
16K4504.05.80.45600 (400)☆80.73
16K6304.05.80.63600 (400)☆77.26
16K8003.55.30.8600 (530)☆61.48
16K12502.84.61.2560040.83
16K20002.84.62.060038.96

Table 3 Heating Cable Specification (600V Double Conductors)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
26C3.412.90.0034150783.76
26C4.412.20.0044160701.56
26C5.811.30.0058170606.16
26C8.69.900.0086180451.43
26C11.49.300.0114200400.05
26C13.89.000.0138210375.20
26C17.28.600.0172220344.90
26C238.000.023250303.25
26C34.47.500.0344280269.20
26C49.27.100.0492300243.84
26K2409.900.24180451.43
26K3209.300.32200400.05
26K3849.000.384210375.20
26K4808.600.48220344.90
26K6408.000.64250303.25
26K9607.500.96280269.20

Table 4 Heating Cable Specification (300V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
23C3.412.00.0034200708.10
23C4.411.30.0044220629.07
23C5.810.40.0058240537.73
23C8.69.000.0086260392.56
23C11.48.400.0114280343.89
23C13.88.000.0138300314.57
23C17.27.600.0172320286.27
23C237.100.023340252.98
23C34.46.600.0344360221.19
23C49.26.200.0492380197.64
23K16010.40.16220508.37
23K2409.000.24240392.56
23K3208.400.32265343.89
23K3848.000.384280314.57
23K4807.700.48300291.91
23K6407.100.64320252.98
23K9606.500.96350216.11

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals;

Mark of (300)☆ is a recommended production length by MICH


Selection Parameters:


Constant Wattage Heating CableHigh Temperature Heating cablePolyamide/Fiberglass Heating CableHarsh Environment Heating CableGeneral Purpose Heating Cable
Available Voltages120, 208, 240, 277 & 480 VAC120, 208, 240, 277 & 480 VAC120, 208, 240, 277 & 480 VAC120, 208, 240, 277 & 480 VAC

Available Wattages


4, 8 & 12 watts/ft (13, 26 & 39 watts/m)4, 8 & 12 watts/ft (13, 26 & 39 watts/m)4, 8 & 12 watts/ft (13, 26 & 39 watts/m)3, 5, 8 & 12 watts/ft (10, 16, 26 & 39 watts/m)
Maximum Exposure Temperature

500°F (260°C)


500°F (260°C)


500°F (260°C)


400°F (204°C)


Nominal Dimensions


0.2"x0.3" (5mm x 8mm) 12 AWG


0.2"x0.3" (5mm x 8mm) 12 AWG


0.2"x0.3" (5mm x 8mm) 12 AWG


0.2"x0.3" (5mm x 8mm) 12 AWG
Resistance to MoistureGoodGood

Excellent


Excellent


Resistance to ChemicalsGoodGood

Excellent


Excellent


Resistance to FlameExcellentOutstandingExcellentOutstanding
Dielectric StrengthOver 2000 volts

Over 2000 volts


Over 2000 voltsOver 2000 volts