1. Design Basis and Water Treatment Standards:
1.1 Raw Water: Municipal tap water or groundwater.
1.2 Product Water Application: Pure water.
1.3 Product Water Flow Rate: 1 ton per hour.
1.4 Product Water Quality: Raw water conductivity ≤ 1000 μS
RO product water conductivity ≤ 10 μS
1.5 System Recovery Rate: ≥60%
1.6 System Process and Configuration for Producing Pure Water: Raw
Water Tank – Raw Water Pump – Quartz Sand Filter – Activated Carbon
Filter – Water Softening Filter – Precision Filter – High-Pressure
Pump – Reverse Osmosis Pure Water System – Pure Water Tank – Pure
Water Boosting Pump – Pure Water Usage Point
1.7 Operating mode: Automatic control operation
1.8 Design scope: From the raw water tank outlet to the ultra-pure
water tank outlet. If the customer requires additional auxiliary
equipment, it can be purchased separately after negotiation with
our company.
1.9 Equipment installation and commissioning comply with the ‘Code
for Construction and Acceptance of Water Supply and Drainage
Engineering’ (GB1328-1995)
2. System Requirements for External Conditions:
2.1 Water Source: Municipal water supply connected to the raw water
tank inlet, flow rate 2 T/H.
2.2 Water Temperature: 5-45°C
2.3 Raw Water Conductivity ≤ 1000 μS/cm
2.4 Power supply: The user shall provide 3 kW/220 V/50 Hz power to
the control cabinet.
2.5 The equipment must be installed indoors to avoid direct
sunlight affecting the equipment.
2.6 A drainage channel is required, with a maximum drainage
capacity of 2 tonnes per hour.
2.7 Indoor lighting fixtures and sufficient space for maintenance
must be provided.
2.8 The equipment room must have good ventilation to avoid the
effects of acid, alkali, and dust on the equipment.
Reverse Osmosis System
Principle Description: Reverse osmosis is a new membrane separation
technology developed in the 1960s. It is a process that uses
reverse osmosis membranes to separate the solvent from the solute
in a solution under pressure.
Osmosis is a physical process. When two solutions with different
salt concentrations are separated by a semi-permeable membrane, the
solution with lower salt concentration will permeate through the
membrane into the solution with higher salt concentration. This
process is called natural osmosis. However, if pressure is applied
to the side with higher salt concentration, the osmosis process can
be halted. This pressure is referred to as osmotic pressure. If the
pressure is increased further, water can permeate in the opposite
direction, while salts do not pass through. Therefore, the
principle of reverse osmosis desalination involves applying a
pressure greater than the natural osmotic pressure to the saline
water, causing osmosis to occur in the opposite direction. This
forces water molecules from the original water to the other side of
the membrane, producing clean water and achieving the goal of
removing salts from the water. This is the principle of reverse
osmosis desalination.
Product features:
1: The system is controlled by full-automatic way, the main components are imported, high stability, easy and convenient operation.
2: High degree of automation, immediate self-stop in case of failure, with automatic protection function.
3: The membrane module is made of composite membrane, showing higher solute separation rate and transmission rate.
4: Low energy consumption, high water utilisation rate, low operating cost.
5: Reasonable structure, small footprint.
6: Advanced membrane protection system, in the equipment shutdown, desalinated water can automatically rinse the membrane surface contaminants to extend the life of the membrane.
7 system has no wearing parts, without a lot of maintenance, long-term effective operation.
8: The equipment is designed with CIP membrane cleaning system.
9 the main electrical components used in France Schneider, quality and quantity assurance, and according to the best configuration design.
10: Remote monitoring system is optional, real-time remote observation of the system operating conditions.
Note: Due to product specificity need to buy the pro please contact our customer service, customer service will be based on the pro's water consumption and water quality problems to recommend the right products to the pro, in order to avoid unnecessary future trouble please do not blindly buy equipment, such as the need for specific details of the specifications and parameters or picture trouble pro contact customer service, we will answer the pro's questions, thank you for the pro's support of the net environmental protection, thanks!
![]() |