Sign In | Join Free | My frbiz.com |
|
Categories | Stationary Meter Test Equipment |
---|---|
Brand Name: | GENY |
Model Number: | YC-1893D |
Certification: | ISO, CE |
Place of Origin: | CHINA |
Payment Terms: | L/C,T/T,D/P |
Model NO.: | YC1893D |
Test voltage output(Phase-Neutral): | 3x(24V~288V)(or customized) |
Voltage supply: | 3x220/380V±10%(or customized) 50/60Hz ±2Hz |
Ambient temperature: | -10°C~+40°C |
Relative humidity: | 35%~85% |
Company Info. |
Guangzhou GENY Electric Co., Ltd |
Verified Supplier |
View Contact Details |
Product List |
1. The meter test system is capable of measuring mechanical and
electronic meters, as well as electronic meters, through automatic,
semi-automatic or manual operation.
2.Meters under testing: 3P4W, 3P3W, 1P2W
3. Testing mode: active power, reactive power, and cross-connected
reactive power.
4. Simultaneously measure meters with the same specifications but
different meter constants.
5. Automatically position the rotor mark of the disc of the
mechanical meter, increasing efficiency.
Initiate the test and creep test.
Carry out the neutral current test (if required).
Install the ICT in each meter position to test three-phase meters
with closed links between the current and voltage measuring
circuits (I-P links) (if required).
Activate the protection function of overload, short voltage circuit
and open current circuit.
10. The synchronised movement of the scanning heads streamlines the
control process.
11. The product is made from aluminium alloy, a lightweight yet
durable and corrosion-resistant material. The testing software,
compatible with Windows 2000, XP, 7, 8 and 10, includes a range of
functional modules for various modern energy meters. These modules
facilitate testing for real-time error, harmonic, demand and
influence, among others.
Technical spec. | YC1893D-6 | YC1893D-12 | YC1893D-24 | YC1893D-48 |
Number of meter positions | 6 | 12 | 24 | 48 |
Accuracy | 0.05 / 0.02 | |||
Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
Standard Meter | SZ03A-K6 / SZ03A-K8 | |||
Scanning Head | YCG-S Series | |||
Voltage | ||||
Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) | |||
Power of the voltage output | Max. 3x100VA | Max. 3x250VA | Max. 3x500VA | Max. 3x1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Current | ||||
Test current output | 3x(1mA~100A) | |||
Power of the current output | Max. 3x150VA | Max. 3x350VA | Max. 3x750VA | Max. 3x1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Phase angle | ||||
Range | 0~360⁰ | |||
Resolution | 0.01⁰ | |||
Setting accuracy | 0.1⁰ | |||
Frequency | ||||
Range | 45Hz~65Hz | |||
Resolution | 0.01Hz | |||
Error display | ||||
Type of error display | Red LED | |||
Resolution of error displays | 8 digitals | |||
Other | ||||
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz | |||
Ambient temperature | -10°C~+40°C | |||
Relative humidity | 35%~85% |