Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home > Electronics Stocks >

NH3 3E 500 SE Electrochemical Gas Sensor Ammonia Gas Sensor 0-500ppm Low Susceptibility To Abrupt Changes Of Humidity Portable & Fixed Point Applications

Categories Gas Sensor
Model Number: NH3 3E 500 SE
MOQ: 1
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time: 3-5work days
Measuring Range: 0-500ppm
Sensitivity Range: 35nA/ppm ± 15nA/ppm
Expected Operating Life: >24 months in air*
Zero Current at 20oC: <± 100nA, typically 40nA
Response Time at 20oC: t50 <30s calculated from 5min. expsoure time t90 <90s calculated from 5min. expsoure time
Temperature Range: -20°C to +40°C
Bias Potential: 0mV
Linearity: <10% full scale
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

NH3 3E 500 SE Electrochemical Gas Sensor Ammonia Gas Sensor 0-500ppm Low Susceptibility To Abrupt Changes Of Humidity Portable & Fixed Point Applications

NH3 3E 100 SE Electrochemical Gas Sensor Ammonia Gas Sensor 0-500ppm Low Susceptibility To Abrupt Changes Of Humidity Portable & Fixed Point Applications


Features:
Amperometric 3 electrode sensor cell
Low susceptibility to abrupt changes of humidity
No CO2 interference
High selectivity
0 voltage biased operation


Typical Applications:

Portable & fixed point applications
Monitoring of IDLH levels, General Industry,
Chemical Industry, Food & Refrigeration Industry


Part Number Information:
Mini 1850-932-30009
Sensoric Classic 1850-932-30069
CTL4 Series Adaptation 1850-932-30049
CTL 7 Series Adaptation 1850-932-30079


Long Term Sensitivity Drift<5% per 6 months
Pressure Coefficient<0.03% signal/mBar
Operating Humidity15-90% RH non-condensing
Effect of HumidityNo effect on zero reading
during abrupt changes of RH
Recommended Load Resistor100Ω
Orientation SensitivityNone
Storage Life4 weeks in container
Recommended Storage Temperature0-20°C


Quality NH3 3E 500 SE Electrochemical Gas Sensor Ammonia Gas Sensor 0-500ppm Low Susceptibility To Abrupt Changes Of Humidity Portable & Fixed Point Applications for sale
Send your message to this supplier
 
*From:
*To: ShenzhenYijiajie Electronic Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0