Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home >

Durable Thermocouple Temperature Probe For Accurate Temperature

Categories Thermocouple Temperature Probe
Brand Name: LEADKIN
Model Number: LK-K
Certification: ISO9001, IATF16949, CE
Place of Origin: NINGBO CHINA
MOQ: 50M
Price: negotiation
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1,000,000M/year
Delivery Time: 2-7 working days
Packaging Details: 70*70*8cm Carton
Core: 2,3,4,6
Insulation: MgO
Warranty: 1 Year
Temperature Range: 200℃-1000℃
Accuracy: Class I、II、III
Outside Dia: 0.5-12.7mm
Package: Carton. Pallet
Function: temperature test
Cable Length: 1-5m or Customized
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Durable Thermocouple Temperature Probe For Accurate Temperature

Quick Details:

Type: K/N/E/J/T/S/R/B

Place of Origin: Zhejiang, China (Mainland)

Accuracy: I-0.4%t, II-0.75%t, III-1.5%t

Core number: 2,3,4,6

Inorganic mineral insulating lead material: Ni, Cu

Insulator: 99.6% high purity MgO

Certificate:ISO9001, IATF16949, CE

Application: connecting with thermocouple and instrument machine

Sheath material: 0Cr18Ni10Ti, SS304S,SS316L,SS316, Cu

Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0


Type for Sheath Wire Type K:

Product NameCodeTypeShaeth MaterialOutside Dia.Temperature
NiCr-NiSi /NiCr-NiAlKKKSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
SS310 Inconel6000.5-1.0500
1.5-3.2800
4.0-6.4900
8.0-12.71000
NiCrSi-NiSiNKNSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
SS310 Inconel6000.5-1.0500
1.5-3.2800
4.0-6.4900
8.0-12.71000
NiCr-KonstantanEKESS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
Fe-KonstantanJKJSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
Cu-KonstantanTKTSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
RhPt10-PhSKSInconel6006.0-12.71100

Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples, the data in the table is only recommended data.


Accuracy for Sheath Wire Type K

TypeClass IClass II
AccuracyTemp.RangeAccuracyTemp.Range
K±1.5℃-40~375℃±2.5℃-40~375℃
±0.4%375℃-1000℃±0.75%375℃-1000℃
N±1.5℃-40~375℃±2.5℃-40~375℃
±0.4%375℃-1000℃±0.75%375℃-1000℃
E±1.5℃-40~375℃±2.5℃-40~375℃
±0.4%375℃-800℃±0.75%375℃-800℃
J±1.5℃-40~375℃±2.5℃-40~375℃
±0.4%375℃-800℃±0.75%375℃-800℃
T±0.5℃-40~125℃±1.0℃-40~125℃
±0.4%125℃-350℃±0.75%125℃-350℃
S0-1100℃±1.0℃0-1100℃±1.5℃

About this product:

Advantages of Thermocouple Temperature Probes

Wide Temperature Range: Can measure a vast range of temperatures, from cryogenic levels to high temperatures.

Fast Response Time: Thermocouples can respond quickly to temperature changes due to their small size.

Robustness: Durable and can withstand harsh environments and conditions.

Simplicity: Simple construction and easy to use, making them suitable for various applications.

Disadvantages of Thermocouple Temperature Probes

Non-linear Output: The output voltage is not linear with temperature, requiring calibration.

Reference Junction Compensation: Requires compensation for the cold junction to ensure accurate readings.

Temperature Drift: Over time, the thermoelectric properties of the metals can change, affecting accuracy.

Susceptibility to Noise: Thermocouples can be affected by electromagnetic interference, requiring careful installation.

Conclusion

Thermocouple temperature probes are essential tools for accurate temperature measurement across various industries and applications. Their design and operation allow for a wide range of temperature measurements, making them suitable for both industrial and scientific applications. Understanding their principles, types, advantages, and limitations is crucial for selecting the appropriate thermocouple for specific temperature measurement needs.


A Resistance Temperature Detector (RTD) cable is a type of electrical cable designed for temperature measurement applications using RTDs. RTDs are sensors that measure temperature by correlating the resistance of the sensor element (usually made of pure metal, like platinum) to temperature. Here are some key points about RTD cables:

Key Features of RTD Cables:

Construction: RTD cables typically consist of multiple conductors, often made of copper, which are insulated to prevent short circuits. The insulation material can vary (such as PVC, Teflon, or silicone) depending on the application and environmental conditions.

Number of Conductors: RTD cables can have two, three, or four wires. The configuration impacts accuracy and the ability to compensate for lead resistance:

2-Wire: Simplest configuration, but less accurate due to lead resistance affecting the measurement.

3-Wire: More common, it compensates for some lead resistance, improving accuracy.

4-Wire: Provides the highest accuracy by completely eliminating lead resistance from the measurement.

Applications :

  • Solid waste incinerators
  • Sintering powdered metals
  • Firing ceramic materials
  • Gas or oil fired furnaces
  • Fuel fired heat exchangers
  • Box furnaces
  • Nuclear or hydrocarbon based energy plants
  • And many more...

Product Pictures:


Company Information:

A. Main Products



B. Package

We add heat shrink tubing and plastic film to make sure high insulated resistance.

Except marking notes, we also have pass card and test report for every coil cable.


C. Mi cable Production line

We have high - quality professional products, as well as advanced product lines and equipments. All of the products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world.Along the increasing market demands, we continuously satisfy customers by updating products to improve prouduction systems, improve quality.


Order Notice:

1. Accurate quotation.

2. Confirm the price, trade term, lead time, payment term etc.

3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.

4. Customer arranges the payment for deposit and sends us bank slip.

5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again.

6. End Production-Mass production products photos.

7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.

8. The order is finished perfectly when you receive the goods and get satisfied with them .

9. Feedback to LEADKIN about Quality , Service, Market Feedback & Suggestion. And we will do better .


Quality Durable Thermocouple Temperature Probe For Accurate Temperature for sale
Send your message to this supplier
 
*From:
*To: Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0