Brand Name: DLX
Model Number: Type T Thermocouple extension wire
Certification: CE,ROHS
Place of Origin: China
MOQ: 5
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 300 tons per month
Delivery Time: 5-21 days
Packaging Details: Spool package with Carton box, Coil package with polybag
Product name: Type T Thermocouple extension wire
Certificate: ISO9001
Temperature range: - 200~350°C
EMF tolerance: +/- 2.2C or +/- .75%
Grade: Extension Grade Type T
Positive: Cu
Negative: Cu-Ni
Special Limits of Error: +/- 1.1C or 0.4%
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

High Temperature Cable Thermocouple Compensation Wire Type T Thermocouple Extension Wire

High Temperature Cable Thermocouple Compensation Wire Type T Thermocouple Extension Wire


  • Thermocouple Extension Wire

T-type thermocouple compensation wire is a special wire used to connect T-type thermocouples with temperature measuring instruments. It is mainly used to extend the cold end of the thermocouple to compensate for the measurement error caused by the change of the cold end temperature. It has excellent thermoelectric performance and stability, and can maintain the same thermoelectric electromotive force characteristics as T-type thermocouples within a certain temperature range (such as -60℃ to 260℃).
T-type compensation wire is usually made of copper-copper-nickel alloy material, and there are many options for insulation layer and sheath materials, such as polyvinyl chloride (PV), polyperfluoroethylene propylene (FEP) and soluble polytetrafluoroethylene (PFA) to meet the use requirements in different environments. Its common models include TX-G (general use), TX-H (general use), TX-GS (precision general use) and TX-HS (precision heat-resistant use).
This compensation wire is widely used in the automated temperature measurement system of petroleum, chemical, metallurgy, electric power and other industries, which can effectively improve the temperature measurement accuracy and ensure the stability and reliability of the measurement system.



  • Thermocouple Wire
CodeWires component of the thermocouple
+Positive leg-Negative leg
NNi-cr-si (NP)Ni-si-magnesium (NN)
KNi-Cr (KP)Ni-Al(Si) (KN)
ENi-Cr (EP)Cu-Ni<constantan> (EN)
JIron (JP)Cu-Ni<constantan> (JN)
TCopper (TP)Cu-Ni<constantan> (TN)


  • ​Standards
ASTMANSIIECDINBSNFJISGOST
(American Society for Testing and Materials) E 230(American National Standard Institute) MC 96.1(European Standard by the International Electrotechnical Commission 584)-1/2/3(Deutsche Industrie Normen) EN 60584 -1/2(British Standards) 4937.1041, EN 60584 - 1/2(Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324(Japanese Industrial Standards) C 1602 - C 1610(Unification of the Russian Specifications) 3044

Detailed Parameter of thermocouple wire

Working Temperature Range


Diameter/mmLong time Working temperature /ºCShort period Working temperature /ºC
0.3700800
0.5800900
0.8,1.09001000
1.2,1.610001100
2.0,2.511001200
3.212001300

Thermocouple No. indexingCompensation wire typeUsag ClassificationMeasuring junction temperature / ℃standard EMF value/μVPrecision gradeGeneral grade
Tolerance μVThermal EMF range μVTolerance μVThermal EMF range μV
SorRSC or RCG100646±30616~676±60586~706
H100646--±60586~706
2001 1441--1.381~1 501
KKX,KCAG-25-968±40-924~-1 012±80-880~-1 056
or KCB1004 0964 052~4 1404 008~4 184
H-25-968±40-924~-1 012±88-880~-1 056
1004 0964 052~4 1404 008~4 184
2008 1388 094~8 1828 050~8 226
NNX or NCG-25-646±43-603~-689±86-560~-732
1002 7742 731~2 8172 688~2 860
H-25-646±43-603~-690±86-560~-732
1002 7742 731~2 8172 688~2 860
2005 9135 870~5 9565 827~5 999
EEXG-25-1 432±81-1 351~-1 513±138-1 294~-1 570
1006 3196 238~ 64006 181~6 457
H-25-1 432±81-1 351~- 1513±138-1 294~-1 570
1006 3196 238~6 4006 181~6 457
20013 42113 340~13 50213 283~13 559
JJXG-25-1 239±62-1 177~-1 301±123-1 116~-1 362
1005 2695 207~5 3315 146~5 392
H-25-1 239±62- 177~-1 301±123-1 116~-1 362
1005 2695 207~5 3315 146~5 392
20010 77910 717~10 84110 656~10 902
TTXG-25-940±30-910~-970±60-850~-1 000
1004 2794 249~4 3094 189~4 339
H-25-940±48-892~-988±90-850~-1 030
1004 2794231~4 3274 189~4 369
200


  • Type T Accuracy

Copper-copper-nickel thermocouple (T-type thermocouple), also known as copper-constantan thermocouple, is an optimal low-cost metal thermocouple for measuring low temperatures. Its positive electrode (TP) is pure copper, and its negative electrode (TN) is a copper-nickel alloy, often called constantan. It is compatible with constantan EN of nickel-chromium-constantan, but not with constantan JN of iron-constantan, although they are both called constantan.
The measurement temperature range of copper-copper-nickel thermocouple is -200~350°C.


  • Feature

Material and structure: T-type compensation wire is usually made of copper (positive electrode) and copper-nickel alloy (negative electrode), and the insulation layer is red (positive electrode) and white (negative electrode).
Temperature range: The operating temperature range of the compensation wire is -40℃ to 70℃ or 105℃ for ordinary grade, and -65℃ to 200℃ or 260℃ for heat-resistant grade.
Accuracy level: It is divided into ordinary grade and precision grade, and the precision grade has higher measurement accuracy.
Anti-interference ability: Some compensation wires adopt shielding design, which can effectively reduce electromagnetic interference.


  • Q&A

Q1: What is the function of T-type thermocouple compensation wire?
A1: T-type compensation wire is used to extend the cold end of the thermocouple and move the reference end of the thermocouple from the high temperature area to a place with a more stable ambient temperature to improve the temperature measurement accuracy.
Q2: What is the material of T-type compensation wire?
A2: The positive electrode material of T-type compensation wire is copper, and the negative electrode material is copper-nickel alloy.
Q3: What is the temperature range of T-type compensation wire?
A3: The operating temperature range of T-type compensation wire is:
Ordinary grade: -40℃~70℃ or -40℃~105℃;
Heat-resistant grade: -65℃~200℃ or -65℃~260℃.