Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home > Other Measuring & Analysing Instruments >

DIN40050-9 Open-Type IPX9K High-Pressure Water Resistance Test System

Categories Water Ingress Testing Equipment
Brand Name: Sinuo
Model Number: SN4412-P12
Certification: Calibration Certificate (Cost Additional)
Place of Origin: China
MOQ: 1
Price: Customized
Payment Terms: T/T
Supply Ability: 1 sets/month
Delivery Time: 45 days
Packaging Details: Other
Nozzle distance: 150-200mm
Water pressure: 8-10MPA
Water temperature: 80℃±5℃
Hydraulic pipe: 3m long
Flow rate: 15L±1/min
Nozzle apertures: 2.34*1.33mm (oval)
Maximum sample weight: ≥80kg
Turntable system: L1500x W1500xH500mm
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

DIN40050-9 Open-Type IPX9K High-Pressure Water Resistance Test System


DIN40050-9 Open-Type IPX9K High-Pressure Water Resistance Test System


Complied Standards & Clauses



Conforms to IEC60529, DIN40050-9, ISO20653, and other standards.


Equipment Overview


The main specimens of this equipment: are passenger cars, buses, lamps, motorcycles, and other vehicles and their parts.

This equipment can simulate the cleaning process conditions of high pressure/steam jet cleaning to test the physical and other related properties of the specimens.

After the test, it can be judged whether the performance of the product meets the requirements. It is convenient for product design, improvement, verification, and factory inspection.


Technical Parameters



IPX9K
User site requirements

1) 6m wide × 4.5m deep × 3m high (users are responsible for the glass room and drainage trough). Please provide the site layout.

2) The user's room needs to have a waterproof system. The floor is paved with high-quality non-slip tiles and can be fixed with bolts. It also has waterproof and anti-penetration effects. The surroundings and top of the room must have waterproof effects.

3) Requirements for drainage troughs around the room: The drainage trough is 200mm wide and 200mm deep. One high and one low inclined. Ensure that the drainage outlet is 200mm deep. Cement board or stainless steel plate is laid on it.

4) When users decorate the room, please reserve the power connection port, water inlet and outlet, gas pipe interface, etc.

Test sampleMaximum length, width and height ≥1200x1200x1200mm, maximum sample weight ≥80kg.
Number of nozzlesThere are 2 nozzles. One is installed on the top (vertical) to spray the top surface of the sample. The other is installed on the bottom (horizontal) to spray the plane around the sample. The spray trajectory is based on the principle of running an S-shaped trajectory. A four-way servo motor design is used to complete the 5-sided water spraying.
Four nozzle apertures2.34*1.33mm (oval)
Nozzle distance150-200mm
Spray angleThe spray can cover the entire surface of the sample, and the spray angle is perpendicular to the sample surface.
Water pressure8-10MPA
Water temperature80℃±5℃
Flow meterElectronic high pressure flow meter
Pressure gaugeHigh pressure meter
Hydraulic pipe3m long
Flow rate15L±1/min
Test Method

(1) The top and five surfaces of the test sample are sprayed with water in turn.

(2) When the shell is tested in test a) and test b), the water temperature should be maintained at (80±5)℃.

(3) For small enclosures (maximum size ≤ 250 mm): The enclosure should be installed on the test device. Rotation speed: (5±1) r/min. Spray angle: 0°, 30°, 60°, 90°. The test time for each position is 30 seconds.

(4) For large enclosures (maximum size ≥ 250 mm): The enclosure should be installed according to the intended use. The entire outer surface of the enclosure will be sprayed. Spray direction: Spray from all directions to cover the entire surface of the enclosure. The spray angle should be as perpendicular to the spray surface as possible. The distance between the nozzle and the test sample under test conditions is (175±25) mm, at least 3 minutes.

Details


Quality DIN40050-9 Open-Type IPX9K High-Pressure Water Resistance Test System for sale
Send your message to this supplier
 
*From:
*To: Sinuo Testing Equipment Co. , Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0