Fluke 190 Series III ScopeMeter® Test Tools F190-062 F190-102 F190-202 F190-502 F190-104 F190-204 F190-504

Categories FLUKE
Brand Name: Fluke
Model Number: Fluke 190 Series III ScopeMeter® Test Tools F190-062 F190-102 F190-202 F190-502 F190-104 F190-204 F190-504
Certification: CCCI
Place of Origin: China
MOQ: 1
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1000pcs
Delivery Time: 15-20days
Packaging Details: Carton
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Fluke 190 Series III ScopeMeter® Test Tools F190-062 F190-102 F190-202 F190-502 F190-104 F190-204 F190-504

Specifications: Fluke 190 Series III ScopeMeter® Test Tools

Oscilloscope Models
190-062190-102190-202190-502190-104190-204190-504
Vertical deflection
Number of channels2222444
Bandwidth60 MHz100 MHz200 MHz500 MHz100 MHz200 MHz500 MHz
Rise time5.8 ns3.5 ns1.7 ns0.7 ns3.5 ns1.7 ns0.7 ns
Number of scope inputs2 input channels plus external trigger4 input channels
Channel architectureAll inputs fully insulated from each other and from ground. Inputs may be activated in any combination.
Input couplingAC or DC, with ground level indicator
Input sensitivityWith 10:1 probe, 20 mV to 1000 V/div
With 100:1 probe, 200 mV to 10 kV/div
Direct (1:1), 2 mV to 100 V/div
Bandwidth limiter20 MHz and 10 kHz
PolarityNormal, Inverted, Variable
Input voltageCAT III 1000 V/CAT IV 600 V rated, see General specifications for further details
Vertical resolution8 bit
Accuracy at 4 s to 10 μs/div5 mV/div to 100 V/div, ±(1.5 % + 6 counts)
2 mV/div, ±(1.5 % + 10 counts)
Input impedance1 MΩ (± 1 %) // 15 pF (± 2.25 pF)
Horizontal
Maximum real- time sample rate (sampled simultaneously)625 MS/s
(each channel)
1.25 GS/s (each channel)2.5 GS/s (each channel)5 GS/s (single channel) or
2.5 GS/s (dual channel)
1.25 GS/s (each channel)2.5 GS/s (2ch)
1.25 GS/s (4ch)
5 GS/s (single ch) or 2.5 GS/s (2ch) or 1.25 GS/s (4ch)
Record lengthUp to 10,000 samples per channel
Time base range10 ns/div
to 4 s/div
5 ns/div
to 4 s/div
2 ns/div
to 4 s/div
1 ns/div
to 4 s/div
5 ns/div
to 4 s/div
2 ns/div
to 4 s/div
1 ns/div
to 4 s/div
Time base in a 1-2-4-sequence
Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’)
Maximum record length10,000 samples per channel in scope mode
30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’)
Timing accuracy± (0.01 % of reading + 1 pixel)
Glitch capture8 ns (10 µs/div to 2 min/div)
Display and acquisition
Display133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD
Display modesAny combination of channels; average on/off; replay.
Visible screen width12 divisions horizontally in scope mode
Digital persistence modesOff, short, medium, long, infinite and envelope mode
Waveform mathematicsOne (190-xx2) or two (190-x04) mathematical operations on 2 input channels (A and B, C and D): add, subtract, multiply; X-Y-mode; Frequency Spectrum using FFT
Acquisition modesNormal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay
Trigger and delay
SourceInput A, B or External (via meter input)Input A, B, C or D
ModesAutomatic, Edge, Pulse Width, N-Cycle, External (190-xx2)
Connect-and- View™Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred.
Pulse width triggering (on channel A)Pulse width qualified by time
Allows for triggeringt, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns
Time delay1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay
Dual slope triggeringTriggers on both rising and falling edges alike
N-cycle triggeringTriggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events.
ReplayManual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp.
Replay storageTen sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port.
FFT—frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
WindowAutomatic, Hamming, Hanning or None
Automatic windowDigitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant.
Vertical scaleLinear/Logarithmic (in volts or amps)
Frequency axisFrequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform compareProvides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope.
Pass/Fail testingIn waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis.
Automatic scope measurements
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), rise time (using cursors), fall time (using cursors), Power Factor (PF), Watts, VA, VA reactive, phase (between 2 inputs A&B or C&D), pulse width (pos./neg.), duty cycle (pos./ neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 Ω and 600 Ω, VPWM ac and VPWM(ac+dc) for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ratio;
Advanced power and motor drive functionsV/Hz ratio, Power Factor (PF), Watts, VA, VA reactive, V-PWM (ac) and V-PWM (ac+dc) for measure- ment on pulsewidth modulated motordrives and frequency inverters
Cursor measurements
SourceOn any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Dual horizontal linesVoltage at cursor 1 and at cursor 2, voltage between cursors
Dual vertical linesTime between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors.
Single vertical lineMin-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant
Advanced functionsmA*s (current-over-time, between cursors); V*s (voltage-over-time, between cursors); W*s (energy, between cursors)
ZOOMRanges from full record overview to zoom in up to sample level, at any record length.
Meter modes
190-062190-102190-202190-502190-104190-204190-504
Meter inputsVia 4 mm banana inputs, fully isolated from scope inputs and scope groundVia BNC scope inputs
Number of readingsOne at a time via DMM inputUp to 4 automatic scope measurements simultaneously
Maximum resolution5,000 counts± 999 counts
(frequency: 9999 counts)
Input impedance1 MΩ (± 1 %) // 14 pF (± 1.5 pF)1 MΩ (± 1 %) // 15 pF (± 2.25 pF)
Advanced meter functionsAuto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording
The specified accuracy is valid over the temperature range 18 °C to 28 °C Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C
Voltage
V dc accuracy± (0.5 % + 6 counts)± (1.5 % + 6 counts)
V ac true rms accuracy
15 Hz to 60 Hz± (1 % + 10 counts)± (1.5 % + 10 counts)
60 Hz to 1 kHz± (2.5 % + 15 counts)
60 Hz to 20 kHz± (2.5 % + 15 counts)
V ac+dc true rms accuracy
15 Hz to 60 Hz± (1 % + 10 counts)± (1.5 % + 10 counts)
60 Hz to 1 kHz± (2.5% + 15 counts)
60 Hz to 20 kHz± (2.5 % + 15 counts)
Voltmeter ranges500 mV, 5 V, 50 V, 500 V, 1,100 V
Resistance
Ranges500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy± (0.6 % + 6 counts)
Other meter functions
ContinuityBeeper on < 50 Ω (± 30 Ω)
Diode testUp to 2.8 V
Current (A)A dc, A ac, A ac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
TemperatureWith optional accessories. Scale factors 1mV/°C or 1mV/°F
Recorder mode
190-062190-102190-202190-502190-104190-204190-504
ScopeRecord™ Roll Mode
Dual or multiple input waveform storage mode, using deep memory
Source and displayInput A, Input B, Dual
All channels sampled simultaneously
Any combination of inputs, up to 4 channels.
All channels sampled simultaneously
Memory depth30,000 data points per channel, each holding min/max pair of information
Min/max valuesMin/max values are created at samples that are measured at high sample rate ensuring capture and display of glitches.
Recording modesSingle sweep, continuous roll; Start-on-Trigger (through external); Stop-on-Trigger (through external)Single sweep, continuous roll; Start-on-Trigger (through any channel); Stop-on-Trigger (through any channel)
Stop-on-triggerScopeRecord mode can be stopped by an individual trigger event, or by an interruption
of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series)
Horizontal scaleTime from start, time of day
ZoomRanges from full record overview to zoom in up to sample level
MemoryTwo multiple input ScopeRecord waveforms can be saved internally for later recall and analysis.
ScopeRecord™ Roll mode sample rate and recording timespan
Time base range4 ms/div to 2 min/div
Recorded timespan4.8 sec to 40 hr
Time/division in ‘view all’ mode0.4 s/div to 4 h/div
Glitch capture8 ns
Sample rate125 MS/s
Resolution160 μsec ~ 4.8 sec
Trendplot™ Recording
Multiple channel electronic paperless recorder. Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time.
Source and displayAny combination of scope measurements, made on any of the input channels, or DMM reading (2-channel instruments)
Memory depth19,200 points (sets) per recording. Each recorded sample point contains a minimum, a maximum and an average value, plus a date- and time-stamp.
RangesNormal view: 5 s/div to 30 min/div; In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Recorded time spanUp to 22 days, with a resolution of 102 seconds; up to 5.5 days for 4 readings.
Recording modeContinuous recording, starting at 5 s/div with automatic time-scale compression
Measurement speedThree automatic measurements per second or more
Horizontal scaleTime from start, time of day
ZoomUp to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail
MemoryTwo multiple input TrendPlot records can be saved internally for later recall and analysis.
Cursor measurements—all recorder modes
SourceAny waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot)
Dual vertical linesCursors may be used to identify Min, Max or Average value of any datapoint in a record, with time between cursors, time from start or absolute time.
General specifications
Input voltage range
Rated maximum floating voltageCAT III 1000 V / CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level)
Probe input voltage VPS410-IICAT III 1000 V / CAT IV 600 V (Maximum voltage between standard 10:1 probe tip and reference lead)
Probe input voltage VPS421CAT III 1000V / CAT IV 600V (Maximum voltage between probe tip or reference lead to GND, 2000V max between probe tip and reference lead)
Maximum BNC input voltageCAT IV 300 V (maximum voltage on BNC input directly)
Maximum volt- age on meter inputCAT III 1000 V / CAT IV 600 V
(safety designed banana input connectors)
Memory save and recall
Memory loca- tions (internal)30 waveform memories plus 10 recording memories plus 9 screen copy memories
30 waveform memoriesEach memory can contain up to 2 or 4 waveforms plus corresponding setups.
10 recording memoriesEach may contain: a 100 Screen Replay sequence, or a ScopeRecord Roll-mode recording (2 or 4 traces), or a TrendPlot recording of up to 4 measurements
External data storageOn PC, using FlukeView™-2 Software, or direct storage on external flash memory drive (maximum 32 GB) through USB host port
ScreencopiesOn PC, using FlukeView™-2 Software, or internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port
VolatilitySaving is done in non-volatile Flash-ROM and all data is secured, independent of battery or power status.
Real-time clockProvides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings.
Case
DesignRugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard.
Kensington lock supported to lock down instrument when left unattended.
Drip and dust proofIP 51 according to IEC60529
Shock and vibrationShock 30 g, vibration (sinusoidal) 3 g / 0.03 g2/Hz (Random), according to MIL-PRF-28800F Class 2
Display size133 mm x 90 mm (5.3 in x 3.5 in) LCD
Resolution1120 pixels x 765 pixels
BrightnessUser-adjustable, up to 300 cd/m2
Mechanical data
Size265 mm x 192 mm x 70 mm (10.5 in x 7.6 in x 2.8 in)
Weight (including battery)2.1 kg (4.6 lb)2.2 kg (4.8 lb)
Power
Line powerUniversal mains adapter/battery charger BC190/830 included, with detachable 2-wire power cords 100 Vac to 240 Vac, ±10 %, 50-60 Hz
Battery powerRe-chargeable Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument
Battery type (incl.) and capacity [+opt. battery]BP290: 10.8V, 2500 mAh
[BP291 (5000 mAh) optional]
BP291: 10.8V, 5000 mAh
Battery charge indicatorBattery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen.
Battery operat- ing time (with backlight low)Up to 3.5 using BP290 (included), up to 7 hours using BP291 (optional)Up to 7 hours using BP291 (included)
Battery charging time2½ hours using BP290; 5 hours using BP291Five hours for BP291
Battery power saving functionsAuto ‘power down’ with adjustable power down time. Automatic ‘display off’ with adjustable power down time.
On-screen battery power indicator
Safety
ComplianceEN61010-1, Pollution Degree 2;
IEC 61010-2-030: CAT IV 600 V / CAT III 1000 V
Environmental
Operating temperatureBattery discharging: 0 °C to 40 °C (32 °F to 104 °F)
Battery charging: 0 °C to 40 °C (32 °F to 104 °F)
Storage temperature-20 °C to 60 °C (-4 °F to 140 °F)
Humidity0 °C to 10 °C (32 °F to 50 °F): noncondensing
10 °C to 30 °C (50 °F to 86 °F): 95 % (±5 %)
30 °C to 40 °C (86 °F to 104 °F): 75 % (±5 %)
40 °C to 50 °C (104 °F to 122 °F): 45 % (±5 %)
Maximum operating altitudeCAT IV 600 V, CAT III 1000 V: up to 2000 m (6 600 feet)
CAT IV 300 V, CAT III 600 V, CAT II 1000 V: up to 4000 m (13 000 feet)
Maximum storage altitude12 km (40,000 ft)
Electro-Magnetic Compatibility (EMC)IEC 61326-1: Industrial;
CISPR 11: Group 1, Class A;
Korea (KCC): Class A Equipment (Industrial Broadcasting and Communication Equipment);
USA (FCC): 47 CFR 15 subpart C.
InterfacesTwo USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry.
USB-host port directly connects to external flash memory drive (up to 32 GB) for storage of waveform data, measurement results, instrument settings and screen copies. Alternatively, this USB-A port may be used to connect a WiFi Adapter for wireless PC connectivity. A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control using FlukeView-2.
Probe calibration outputDedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel.
Generator Output: 1.225 Vpp / 500 Hz square wave
Warranty3 years on main instrument, 1 year on battery and accessories
Included accessories
Battery charger/ mains adapterBC190/830
Li-Ion battery packBP290 (10.8V, 2500 mAh)BP291 (10.8V, 5000 mAh)
Voltage probe sets. Each set includes ground lead, hook clip; ground spring and probe tip insulation sleeve with VPS410-II-x.2 pcs VPS421-x, ruggedized industrial-grade probes, 100:1, 150MHz with shrouded 4mm banana tip and large jaw alligator clips (one red, one blue)2 pcs VPS410-II-x, 10:1 voltage probes, 500 MHz, (one red, one blue)4 pcs VPS421-x, ruggedized probes, 100:1, 150 MHz, (red, blue, grey, green)4 pcs VPS410-II-x, 10:1 voltage probes, 500 MHz, (one red, one grey, one blue, one green)
Test leadsTL175 (one red, one black) with test pins
OtherLi-Ion battery (BP290 or BP291, see above), Battery charger (BC190) with universal power cord set, Hangstrap, Handstrap (user selectable for left- or right hand use), download information for user manual and FlukeView®-2 demo package (with restricted functionality), and USB interface cable for PC connectivity. Feedthrough cable terminator, 50 Ω (one per channel, 190-50x only).
Optional configurationEach model is available as a ‘boxed’ version, described above, or with the optional SCC293 set included. SCC293 comprises: CXT293 rugged protective carrying case, full-version FlukeView PC software (activation code) and a WiFi dongle for wireless PC-connectivity using FlukeView-2 software.
Optional accessoriesSCC293, VPS101 - 1:1 voltage probe; VPS510-x - wide bandwidth compact probes; i400s–current clamp; HH290–hanging hook; CXT293–protective carrying case; TRM50–BNC Feedthrough cable terminator, 50 Ω, safety designed; EBC290–battery charging bay
Quality Fluke 190 Series III ScopeMeter® Test Tools F190-062 F190-102 F190-202 F190-502 F190-104 F190-204 F190-504 for sale