Advanced High Temperature Flush Diaphragm Pressure Sensor For Liquid Pressure Measurement Transmitter BP93420-IIIQ

Categories Flush Diaphragm Pressure Sensor
Brand Name: HT SENSOR
Model Number: BP93420-IIIQ
Certification: ISO9001
Place of Origin: Baoji,China
MOQ: 1
Price: Negotiable
Payment Terms: Western Union, L/C, T/T
Supply Ability: 5000PCS/Month
Delivery Time: 5-8 work days
Packaging Details: Standard Export Package
Model NO.: BP93420-IIIQ
power supply: 12-36VDC
ouptut: 4-20mA with LCD or LED display
Pressure Type: Gauge Pressure, Absolute Pressure, Sealed Pressure
Range: 0-35kpa~3.5Mpa
Structure Type: Flush Diaphragm Pressure Sensor
Measuring Medium: Liquid,gas ,Beverage glue and so on
Accuracy Grade: 0.5%
IP Rating: IP65
Customization: Available OEM and ODM
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Advanced High Temperature Flush Diaphragm Pressure Sensor For Liquid Pressure Measurement Transmitter BP93420-IIIQ

Advanced Flush Diaphragm Pressure Sensor for Liquid Pressure Measurement BP93420-IIIQ

BP93420-IIIQ Pressure Transmitter


Introduction of flush diaphragm pressure sensor:

BP93420-IIIQ film pressure sensor transmitter is a simulation of pressure transmitter, using flat film structure, increasing the contact area with the medium.Wide temperature range, strong overload capacity, strong corrosion resistance, wide application. Simple structure, easy to clean, especially suitable for liquid food pressure measurement.


Performance Parameters of Flush Diaphragm Pressure Sensor
Measurement Range of Flush Diaphragm Pressure Sensor-100kPa…0kPa ~ 35kPa…3.5MPa
Pressure TypeGauge Pressure, Absolute Pressure, Sealed Pressure
Overload≤ 1.5 times of the rated range
Accuracy @ 25ºC±0.25% (Typical) ±0.5% (Maximum)
Repeatability≤0.1%FS
Hysteresis≤0.1%FS
Long-Term Stability±0.1%F.S/Year(Typical) ±0.2%F.S/Year(Maximum)
Zero Point Temperature Drift±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa)
Full Scale Temperature Drift±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa)
Frequency Response2.4Khz
Compensation Temperature0-70ºC(≤10mpa,customizable)
Operating Temperature-20ºC~80ºC
Storage Temperature-40ºC~120ºC
Vibration10g,55Hz ~ 2kHz
Housing Material304,316L
Diaphragm Material316L
Insulation Resistance100MΩ 100VDC
Explosion-proof RatingEx ia IIC T6 Ga
Protection RatingIP65
O-Ring SealFluoro rubber
Weight~0.3kg




Product Features of flush diaphragm pressure sensor:

  • 1. Wide measurement range,Various pressure interface options
  • 2. Diverse output signal options
  • 3. Adjustable zero and full-scale
  • 4. High accuracy,multiple sterile process connections


Applications of flush diaphragm pressure sensor:

  • 1. Suitable for measurement of non-corrosive gases and liquids with 316L.
  • 2. Used for aseptic processing in medical, biopharmaceutical, food hygiene and other industries.
  • 3. Used in the paper and chemical industries, as well as in sewage level and beverage tank pressure measurement, suitable for hydraulic and pneumatic control systems​.
Output Signal of flush diaphragm pressure sensorSupply VoltageOutput Type
4~20mA12~30VDC2/3/4 wire
0~10/20mA
3 wire
0/1~5V
0/1~10V
0.5~4.5V5VDC
RS485 Communication Protocol3.6~30V / Battery4 wire

Hengtong 4-20mA Sanitary Clamp Type Smart Pressure Transmitter


Hengtong 4-20mA Sanitary Clamp Type Smart Pressure Transmitter

Hengtong 4-20mA Sanitary Clamp Type Smart Pressure Transmitter

Ordering tips of flush diaphragm pressure sensor
  • 1. When selecting the product, please ensure that the tested medium is compatible with the contact part of the product.
  • 2. When placing an order, please note that explosion-proof products do not include digital display heads.
  • 3. When ordering a transmitter with LCD or LED display head, the power supply of the transmitter should not be less than 20VDC.
  • 4. To ensure the reliable operation of the product, you are advised to install lightning protection devices on site and ensure that the product and power supply are reliably grounded.
  • 5. The rated operating temperature range of fluorine rubber O-ring is -20℃~ 250℃. When the operating temperature of the product is lower than -20 ° C, EPDM O-type sealing ring should be selected.
  • 6. The default cable length is 1.5m and there are three kinds of materials to choose from. If there are no special instructions, polyethylene cable materials can be used. If you need a different cable material, please specify it in the order form.
  • 7. In case of special requirements such as strong vibration, instantaneous impact force, strong electromagnetic or RF interference, please inform us and indicate in the order.​