Model | MHT-25K-100 MHT-30K-100 MHT-36K-100 MHT-40K-100 MHT-50K-100 |
PV Input |
Recommended Max. input power [kW] | 37.5 45.0 54.0 60.0 75.0 |
Start-up voltage [V] |
135 135 135 135 135 |
Max. DC input voltage* [V] | 1000* 1000* 1000* 1000* 1000* |
Rated DC input voltage [V] | 620 620 620 620 620 |
MPPT voltage range* [V] | 200-850* 200-850* 200-850* 200-850* 200-850* |
No. of MPP trackers | 4 4 4 4 4 |
No. of DC inputs per MPPT | 2 2 2 2 2 |
Max. input current [A] | 30×4 30×4 30×4 30×4 30×4 |
Max. short-circuit current [A] | 40×4 40×4 40×4 40×4 40×4 |
Battery Side |
Battery type | Lithium Battery (with BMS) |
Battery voltage range [V] | 135-750 |
Maximum charging/discharge current [A] | 100/100 |
Grid Side |
Rated output power [kW] | 25.0 30.0 36.0 40.0 50.0 |
Max. output apparent power [kVA] | 27.5 33.01) 39.6 44.0 55.0 |
Max. input apparent power** [kVA] | 30.0 36.0 43.5 48.0 60.0 |
Max. charging power of battery [kW] | 25.0 30.0 36.0 40.0 50.0 |
Rated AC voltage | 3L/N/PE; 220/380V;230/400V;240/415V |
Rated AC frequency [Hz] | 50/60 50/60 50/60 50/60 50/60 |
Max. output current [A] | 42.0 50.02) 60.0 66.0 83.0 |
Power factor | 0.8 leading …0.8 lagging |
Max. total harmonic distortion | <3% @Rated output power |
DCI | <0.5%In <0.5%In <0.5%In <0.5%In <0.5%In |
Back-up Side |
Rated output power [kW] | 25.0 30.0 36.0 40.0 50.0 |
Max. output apparent power [kVA] | 27.5 33.0 39.6 44.0 55.0 |
Max. output current [A] | 42.0 50.0 60.0 66.0 83.0 |
UPS switching time | <20ms <20ms <20ms <20ms <20ms |
Rated output voltage | 3L/N/PE; 220/380V;230/400V;240/415V |
Rated output frequency [Hz] | 50/60 50/60 50/60 50/60 50/60 |
Voltage harmonic distortion | <3% @Linear load |
Generator Side |
Max. intput apparent power** [kVA] | 30.0 36.0 43.5 48.0 60.0 |
Max. charging power of battery [kW] | 25.0 30.0 36.0 40.0 50.0 |
Rated AC voltage | 3L/N/PE; 220/380V;230/400V;240/415V |
Rated AC frequency [Hz] | 50/60 50/60 50/60 50/60 50/60 |
Efficiency |
Max. efficiency | 98.8% 98.8% 98.8% 98.8% 98.8% |
European efficiency | 98.3% 98.3% 98.3% 98.3% 98.3% |
Protection |
DC reverse polarity protection | Integrated |
Battery input reverse connection protection | Integrated |
Insulation resistance protection | Integrated |
Surge protection | Integrated |
Over-temperature protection | Integrated |
Residual current protection | Integrated |
Islanding protection | Integrated |
AC over-voltage protection | Integrated |
Overload protection | Integrated |
AC short-circuit protection |
Integrated |
General Data |
Over voltage category | PV: II Main: III |
Dimensions [W×H×D mm] |
800×620×300 |
Weight [KG] | 72.0 |
Protection degree | IP65 |
Standby self-consumption [W] | <15 |
Topology | Transformerless |
Operating Temperature Range [°C] | -30~60 |
Relative Humidity [%] | 0~100 |
Operating Altitude [m] | 3000 (>3000mderating) |
Cooling | Smart fan |
Noise Level [dB] | <50 |
Display | OLED & LED |
Communication | CAN, RS485,WiFi/LAN (Optional) |
* PV Max. Input voltage is 850V, otherwise inverter will be
waiting;
** Max apparent power from the grid means the maximum power
imported from the utility grid used to satisfy the backup loads and
charge the battery;