Sign In | Join Free | My frbiz.com |
|
Categories | Pressure Transmitter Sensor |
---|---|
Brand Name: | HT sensor |
Model Number: | BP156 |
Certification: | CE,RoHs,ISO9001 |
Place of Origin: | Baoji,China |
MOQ: | 1 |
Price: | Negotiable |
Payment Terms: | Western Union, L/C, T/T |
Supply Ability: | 2000PCS/Month |
Delivery Time: | 5-8 work days |
Packaging Details: | Standard Export Package |
Model NO.: | BP156 |
Connenctor: | M12*1 |
Compensation Temperature: | -10~70℃ |
Housing Material: | 316L |
Pressure Type: | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Transport Package: | Standard Export Packing with Carton |
Origin: | Baoji, China |
HS Code: | 9026201090 |
Structure Type: | Weled |
Measuring Medium: | Liquid or Gas |
Accuracy Grade: | 0.25%, 0.5% |
Pressure range: | 0kpa~10kpa...20MPa |
IP Rating: | IP65 |
Customization: | Available | Customized Request |
Company Info. |
Baoji Hengtong Electronics Co., LTD |
Verified Supplier |
View Contact Details |
Product List |
The loose silicon pressure transmitter indirectly measures the measured pressure by measuring the deformation of the silicon diaphragm and converts it into the corresponding electrical signal output. Due to its lightweight nature, the lightweight pressure transmitter is suitable for mobile or temporary applications and is easy to install and use in different locations
Product Features:
1. Wide measuring range, stainless steel structure, diverse
pressure interface forms
2. IP65 protection rating stainless steel structure
3. Zero and full-scale adjustable
4. High precision, all stainless steel structure
Applications:
1. Pressure measurement of non-corrosive gases and liquids with
316L stainless steel
2. Applied in the marine and aviation industries
3. Used in industrial on-site processes such as petroleum,
chemical, metallurgy, power generation, and hydrology
4. Utilized in hydraulic and pneumatic control systems
Performance Parameters: | |
Measurement Range | 0kPa ~ 10kPa…20MPa |
Pressure Type | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Overload | ≤ 1.5 times of the rated range |
Accuracy @ 25ºC | ±0.25% (Typ.) ±0.5% (Max.) |
Repeatability& Hysteresis | 0.02%F.S(Typ.) 0.05%F.S(Max.) |
Long-Term Stability | ±0.1%F.S/Year(Typ.) ±0.2%F.S/Year(Max.) |
Zero Point Temperature Drift | ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa) |
Full Scale Temperature Drift | ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa) |
Frequency Response | 2.4Khz |
Compensation Temperature | 0-70ºC(≤10mpa,customizable) |
Operating Temperature | -20ºC~80ºC |
Storage Temperature | -40ºC~120ºC |
Vibration | 10g,55Hz ~ 2kHz |
Housing Material | 304,316L |
Diaphragm Material | 316L |
Insulation Resistance | 100MΩ 100VDC |
Explosion-proof Rating | Ex db IIC T6 Gb |
Protection Rating | IP65 |
O-Ring Seal | Fluoro rubber |
Weight | ~0.05kg |
Output Signal | Supply Voltage | Output Type |
4~20mA | 12~30VDC | 2/3/4 wire |
0~10/20mA | 3 wire | |
0/1~5V | ||
0/1~10V | ||
0.5~4.5V | 5VDC |
Selection Examples:
Ordering tips: |
1. Measurement range: Determine the required pressure measurement
range, i.e. the minimum and maximum pressure values to be measured.
Ensure that the measurement range of the selected diffused silicon
pressure transmitter meets the requirements of the application.
2. Output signal type: Determine the desired output signal type,
such as an analog signal (such as 4-20mA or 0-10V) or a digital
signal (such as RS485 or Modbus). Make sure the output signal type
of the transmitter you choose is compatible with your control
system or device.
3. Accuracy requirements: Determine the required pressure
measurement accuracy. Different applications may have different
accuracy requirements, choose the diffused silicon pressure
transmitter that suits your application needs.
4. Temperature range: Consider the temperature range of the
application environment to ensure that the selected transmitter can
work properly in this temperature range.
5. Media compatibility: Understand the properties of the medium
being measured, such as liquid or gas, and ensure that the selected
diffused silicon pressure transmitter is compatible with that
medium.
6. Mounting method: Determine the mounting method of the
transmitter, such as flange mounting, thread mounting or other
methods. Make sure the transmitter you choose matches your
installation needs.
7. Protection: Consider the protection level requirements of the
application environment, such as waterproof and explosion-proof
levels. Select a diffused silicon pressure transmitter that meets
the requirements.
8. Certification and standards: Find out if the selected
transmitter complies with relevant certification and standard
requirements, such as CE certification, RoHS directive, etc.
9. Supplier selection: Select a reliable supplier with a good
reputation and reliable after-sales service to ensure product
quality and after-sales support
Order Guide: | |||||||||
BP15X | Analog Pressure Transmitter | ||||||||
Code | Outline Construction | ||||||||
5 | Packard plug | 6 | Sealed Direct Output Cable 1.5 meters | ||||||
7 | Mini Hirschmann Connector | 8 | Large Hirschmann Connector | ||||||
Measurement Range | 0kPa ~ 10kPa…20MPa | ||||||||
(0-X)Kpa or MPa | X: Indicates the Actual Measuring Range | ||||||||
Code | Power Supply | ||||||||
D1 | 24VDC | ||||||||
D2 | 5VDC | ||||||||
D3 | Other | ||||||||
Code | Output Signal | ||||||||
S1 | 4~20mADC | S5 | 0~20mADC | ||||||
S2 | 1~5VDC | S6 | 0~10VDC | ||||||
S3 | 0~5VDC | S7 | 0.5~4.5VDC | ||||||
S4 | 0~10mADC | ||||||||
Code | Pressure Connection | ||||||||
J1 | M20×1.5 | ||||||||
J2 | G1/2 | ||||||||
J3 | G1/4 | ||||||||
J4 | 7/16-20UNF | ||||||||
J5 | Others(¢50.4 Flange) | ||||||||
Code | Electrical Connection | ||||||||
B1 | Hirschmann | ||||||||
B2 | PG7 | ||||||||
B3 | Cable Sealed Outlet 1.5 meters | ||||||||
B4 | Other | ||||||||
Code | Pressure Type | ||||||||
G | Gauge Pressure | ||||||||
A | Absolute Pressure | ||||||||
S | Sealed Reference Pressure |
![]() |