Transformer Type: Pad Mounted
Capacity: 1000Kva Or Customize
Primary Voltage: 12470V Or Customize
Secondary Voltage: 480Y/277
Vector Group: DYN1
Frequency: 60Hz
Insulation Rating: Class E Insulation - 120°C, 248°F
Ratings: Meets/Exceeds DOE 2016 Efficiency Ratings
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

1000kva Three Phase Pad Mounted Transformer Step-Down 12470v To 480y/277

1000kva Three Phase Pad Mounted Transformer Step-Down 12470v To 480y/277


Three phase pad mounted transformer is designed to use in underground distribution systems, Their sealedhigh-vollage and low-vollage safely compartmenls ensure their safe operation and reduce the risk of accidenls, making themideally suited for use in residential applicalions, tourist sites, hotels and other buildings. Pad mounted ransformers are placedinside a cabinet with doors and locks, usually located outdoors.



Main data


Transformer TypePad Mounted, Compartmental-Type
OperationStep-Down Operation (Not Approved for Step-Up)
PhaseThree Phase
Capacity1 MVA (1000 KVA)
Vector GroupDYN1
Primary Voltage12470V
Primary Voltage Class15 kV Class
Primary PhasorDelta
Primary BIL95 KV
Secondary Voltage480Y/277
Secondary BIL30 KV
Frequency60 Hz
Temperature Rise65°C
Insulation RatingClass E Insulation - 120°C, 248°F
Cooling ClassKNAN; Self-Cooled
Liquid Level IndicatorAnalog Dial Gauge
Temperature IndicatorAnalog Dial Gauge
Pressure/Vacuum IndicatorAnalog Dial Gauge
Winding MaterialCopper
Ambient Temperature Rating40°C
Ambient Operating Temperature Range-40°C to +40°C (-50°F to +104°F)
Sound Level58 dBA
Elevation (Altitude)3300ft (1000 meters) Above Sea Level
Core MaterialGrain Oriented Steel
Enclosure RatingNEMA 3R Weatherproof Wiring Cabinet, Sealed Tank
Dimensions*73-W x 69-D x 73-H
RatingsMeets/Exceeds DOE 2016 Efficiency Ratings
Efficiency %99.20%
No Load Loss (in watts)+/- 1,300W
Full Load Loss (in watts) at 100%+/- 8,500W

Standard Features


60 Hz operation.
• 65°C average winding rise.
• Radial & loop feed arrangements.
• Dead and live front type of HV terminals.
• HV BIL 45 – 150 kV (Dead Front) 200 kV (Live Front).
• LV BIL 30 – 60 kV.
• Three-point latching of low-voltage door.
• High-voltage door, which can be opened only after
the low-voltage door is opened.
• Rigid steel partition.
• Transformer tank welded from cover to base.
• Permanent nameplate.
• One-inch NPT pipe cap filling provision.
• ANSI tank ground pads.
• One-inch drain valve and sampler.
• Automatic pressure-relief valve (35 SCFM).
• Tap changer with (2) 2.5% full capacity taps above
and below nominal.
• One 10”x18” (or 14”x25”) hand hole in transformer
tank cover.
• Painted olive-green color (Munsell 7GY 3.29/1.5).
• Designed, manufactured and tested in accordance
with the latest ANSI standards


Technical drawings



Specification


Tachnical Data for Three Phase Pad Mounted Transformer
Rated CapacityLoss(w)Dimension(mm)Weight(kg)
No-load Loss(W)On-load LossWDHOil Weight (L)Total Weight (KG)
45kVA160100017309901270416950
75kVA1801250173099012704351020
150kVA28022001730124512704731225
300kVA48036501830129512706051655
500kVA68051002260134512707202110
750kVA980750022601448162810222950
1000kVA11501030022601500162513253720
1500kVA16401450022101470215015524672
2000kVA21602064523801600222018555670
2500kVA26802778630701650233020066580
3000kVA33003030032601850246023367500
3750kVA41253787540802060268026508450

Production process


150KVA Three Phase Pad Mount electrical Transformer Oil Immersed 13.8KV 4

150KVA Three Phase Pad Mount electrical Transformer Oil Immersed 13.8KV 5

150KVA Three Phase Pad Mount electrical Transformer Oil Immersed 13.8KV 6


FAQ


1. Q: Can I have a sample order?

A: Yes, we welcome sample order to test and check quality.

2. Q: What is the lead time?

A: Mass production time 15-25 days.

3. Q: How long is the warranty?

A: 24 monthes from B/L. If there are any accessory problems,just provide the photos of damaged accessory,then we will provide free service. According to the number of products,we will provide easily damaged accessories for free. we also can provide technical support if you need.

4. Q: Is OEM/ODM available?

A: Yes,it is! We are manufacturer with our own R&D team, we can customize products according to customer's drawing or requirements.

Customized services:

a. Customized color and special function.

b. Customized box.

c. Print customer's logo.

d. Your other ideas about product, we can help you design and put them into production. The above customized services must be confirmed before production.

5. Q: How to control the products quality?

A: Our company owns the core technology ,all kinds of products hold CE certificate. We have professional engineers. Workers are strictly required to make products according to the drawings. Each process has technical instructors.The QC supervisors will regularly inspect the production. We will do products performance tests during production, and comprehensive quality tests when the products is completed.

Quality 1000kva Three Phase Pad Mounted Transformer Step-Down 12470v To 480y/277 for sale
Send your message to this supplier
 
*From:
*To: Xiamen Winley Electric Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0