Sign In | Join Free | My frbiz.com |
|
Categories | Miniature Cartridge Fuse |
---|---|
Brand Name: | LinKun |
Model Number: | 612 Series |
Place of Origin: | China DongGuang |
Certification: | UL ROHS CCC CUL VDE |
MOQ: | 1000PCS |
Price: | Negotiation |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union |
Supply Ability: | 100,000 pieces/month |
Delivery Time: | 5-7 days |
Packaging Details: | PE bag, Bulk |
Rated Current:: | 500mA To 30A |
Operating Temperature:: | -55℃ To +125℃ |
Main Characteristics:: | Miniature Cartridge Fuse; Fast-Acting(F) |
End Caps:: | Nickel-plated Brass |
Axial Leads:: | Tin-plated Copper Wires |
Rated Voltage:: | 250V AC |
Fast acting: | Glass Tube |
Storage Conditions:: | +10℃ To +60℃ |
Standard:: | UL248-14 (IEC 60127-2) |
High Light:: | 30A Glass Cartridge Fuse, 6x30mm Glass Cartridge Fuse, 30 Amp Micro Cartridge Fuse |
Company Info. |
Dongguan Linkun Electronic Technology Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
UL UR CQC 1A 5A 10A 15A 20A 25A 30A Slow Blow Time-lag Time Delay Glass Cartridge 6x30mm Tube Fuse
Series: 6x30mm tube fuse
Product Keywords: No.612/6*30mm time-lag glass fuse
Rated current: 500mA to 30A
Rated voltage: 125V 250V AC
Certification: cULus,cURus,PSE,CQC
Type: Time-lag glass fuse
Lead wire: W, W/O
612 series are time-lag and low breaking capacity fuses, suitable
for 250V AC voltage, breaking capacity less than 200A protection
circuit.
612 series fuses are suitable for use in electronic equipment and
equipment protection circuits.
Time-current characteristics: time-lag fuse (T)
Dividing capacity:
10KA@125VAC,35A@250VAC[500mA-1A];10KA@125VAC,100A@250VAC[1.25-3.15A],10KA@125VAC,200A@250VAC[4A-8A],400A@125VAC,200A@250VAC[10A-20A];400A@125VAC,100A@250VAC[25A-30]
Standard: UL248-14 (IEC 60127-2)
Accreditation: cULus,cURus,PSE,CQC
Material: shell - glass tube, metal cap - nickel - plated brass,
lead cap - nickel - plated cap, tin - plated copper wire
Operating temperature: -55℃ ~ +125℃
Solderability: 260℃≤5 seconds (wave soldering);350℃≤3 seconds
(manual welding)
Welding temperature bearing capacity: 260℃, 10 seconds;280℃, 5 seconds;
Storage condition: +10℃ ~ +60℃;The annual average relative humidity
is less than 75%, and the relative humidity reaches 95% for a
maximum of not more than 30 days
Time VS Current Characteristics:UL248-14 GB/T9364.7 | ||||||
Rated current | 100% | 135% | 200% | 275% | 400% | 1000% |
500mA- ~30A(UL) | >4h | <1h | 5 s~60 s | / | / | / |
8A/10A/16A(GB) | >4h | / | <120 s . | 600 ms~10 s | 150 ms~3 s | 20 ms~300 ms |
Electrical Characteristics at 25 C | |||||||||
Amp | Ratede Current | Max.Voltage | Nominal Melting I2t(A2sec) | Typical Cold Resistance (mΩ) | Breaking Capacity | Approvals | |||
cULus | cURus | CQC | PSE | ||||||
0500 | 500 mA | 125V AC | 0.49 | 1000 | 10KA@125VAC 3 5A@250VAC | ● | ○ | ○ | ○ |
0630 | 630 mA | 1.10 | 840 | ● | ○ | ○ | ○ | ||
0800 | 800 mA | 1.96 | 517 | ● | ○ | ○ | ○ | ||
1100 | 1.00 A | 4.84 | 353 | 10KA@125VAC 100A@250VAC | ● | ○ | ○ | ○ | |
1125 | 1.25 A | 6.76 | 228 | ○ | ○ | ○ | ○ | ||
1150 | 1.50 A | 250V AC | 26.01 | 210 | ● | ○ | ○ | ○ | |
1200 | 2.00 A | 30.25 | 124.4 | ● | ○ | ○ | ○ | ||
1250 | 2.50 A | 47.61 | 74 | ● | ○ | ○ | ○ | ||
1300 | 3.00 A | 121 | 74.11 | ● | ○ | ○ | ○ | ||
1315 | 3.15 A | 132 | 76.67 | 10KA@125VAC 200A@250VAC | ○ | ○ | ○ | ○ | |
1400 | 4.00 A | 324 | 37 | ● | ○ | ○ | ○ | ||
1500 | 5.00 A | 361 | 29.82 | ● | ○ | ○ | ○ | ||
1600 | 8.00 A | 462 | 19.7 | ● | ○ | ○ | ○ | ||
1700 | 7.00 A | 462 | 21.06 | ● | ○ | ○ | ○ | ||
1800 | 8.00 A | 676 | 8.70 | ● | ○ | ● | ○ | ||
2100 | 10.00 A | 1190 | 8.30 | 400A@125VAC 200A@250VAC | ○ | ● | ● | ○ | |
2120 | 12.00 A | 1640 | 6.84 | ○ | ● | ○ | ○ | ||
2150 | 15.00 A | 2500 | 5.20 | ○ | ● | ○ | ● | ||
2160 | 16.00 A | 2601 | 4.66 | ○ | ● | ● | ○ | ||
2200 | 20.00 A | 3249 | 3.30 | ○ | ● | ○ | ● | ||
2250 | 25.00 A | 125V AC | 7225 | 2.50 | 400A@125VAC 100A@250VAC | ○ | ● | ○ | ○ |
2300 | 30.00 A | 8081 | 2.14 | ○ | ● | ○ | ○ |
Notes : 1. Permissible continuous operating current is ≤100% at
ambient temperature of 23°C (73.4°F)
2.The current values used for calculating I2T should be within the
standard range of 8ms ~ 10ms.
![]() |