Number | Equipment/components | Device Description | Amount | unit |
First | First-level HDCY integrated desulfurization wastewater treatment
system | HDC-A-3-0(F) | 1 | Set |
1 | One-stage high-efficiency reactor | Effective volume: 3.5m³, size: 1.2x2.4x1.5m, carbon steel lined
with rubber | 1 | Unit |
2 | First level mixer A | Size φ600x1200mm, rotation speed 70rpm, | 1 | Unit |
Fixed frequency 50hz, material: current parts 2205 |
3 | First-level mixer B | Size φ600x1200mm, rotation speed 150rpm, | 1 | Unit |
Frequency conversion 0~50hz, material: current parts 2205 |
4 | Dry powder dosing machine | Drug storage volume 100L, feeding speed: 0~3kg/h, material 304,
auxiliary devices: moisture-proof heating, vibration motor, low
material level switch, frequency conversion | 1 | Unit |
5 | First level lift pump | Flow rate 3m³/h, lift 20m, | 2 | Unit |
Frequency conversion 0~50hz, material: current parts CR30 |
6 | One-stage high-efficiency cyclone clarifier | Processing capacity: 3m³/h, size: φ1.5x4.7m, material: carbon steel
lined with rubber. | 1 | Unit |
|
Second | Secondary HDCY integrated desulfurization wastewater treatment
system | HDC-A-3-0(F) | 1 | Set |
1 | Two-stage high-efficiency reactor | Effective volume: 3.5m³, size: 1.2x2.4x1.5m, carbon steel lined
with rubber | 1 | Unit |
|
2 | Secondary mixer A | Size φ600x1200mm, rotation speed 70rpm, | 1 | Unit |
Fixed frequency 50hz, material: current parts 2205 |
3 | Secondary mixer N | Size φ600x1200mm, rotation speed 150rpm, | 1 | Unit |
Frequency conversion 0~50hz, material: current parts 2205 |
4 | Dry powder dosing machine | Drug storage volume 100L, feeding speed: 0~3kg/h, material 304,
auxiliary devices: moisture-proof heating, vibration motor, low
material level switch, frequency conversion | 1 | Unit |
5 | Secondary lift pump | Flow rate 3m³/h, lift 20m, | 2 | Unit |
Frequency conversion 0~50hz, material: current parts CR30 |
6 | Two-stage high-efficiency cyclone clarifier | Processing capacity: 3m³/h, size: φ1.5x4.7m, material: carbon steel
lined with rubber. | 1 | Unit |
|
Third | Dosing system | | | |
1 | Lye | Flow rate 50L/h, lift 35m, | 1 | Set |
Dosing system | Frequency conversion 0~50hz, material: pump head PTFE |
2 | Fluoride remover | Flow rate 50L/h, lift 35m, | 1 | Set |
Dosing system | Frequency conversion 0~50hz, material: pump head PTFE |