21.53.112195012 PS900K Power Supply Board For Edan IM8 Patient Monitor

Categories Patient Monitor Parts
Brand Name: Edan
Model Number: 21.53.112195012
MOQ: 1pcs
Payment Terms: T/T(wire transfer), Western Union, Paypal
Delivery Time: 3-5 working days
Packaging Details: Carton
Product Name: Power Supply Board 21.53.112195012 PS900K For Edan IM8 Patient Monitor
Brand: Edan
Part No: 21.53.112195012
Application: Edan IM8 Patient Monitor
Voltage: 00 V to 240 V~
Power frequency: 50 Hz/60 Hz
Current: Current
Fuse: T3.15 AH250 VP
MOQ: One piece
Warranty: 90 days
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

21.53.112195012 PS900K Power Supply Board For Edan IM8 Patient Monitor

Edan IM8 patient monitor power supply board 21.53.112195012 PS900K


About Edan IM8 patient monitor power supply board 21.53.112195012 PS900K


The Edan IM8 patient monitor power board converts electrical power from the wall outlet into a form that the monitor can use. It is usually located inside the monitor and is responsible for providing the voltage and current necessary to power the device.

This is a component of the Edan IM8 patient monitoring system. This card is responsible for providing the monitor with the necessary energy to guarantee its correct operation.

Power boards typically draw power from an external power source, such as a wall outlet or battery. This energy is then converted and distributed to the various components of the patient monitor, including the display, processor, memory, and other internal circuitry.

Power supply boards are designed to accept a wide range of input voltages and currents to ensure compatibility with a wide range of power sources. To protect against possible electrical interference or surges, they are also equipped with various protection mechanisms, such as overcurrent and overvoltage protection.

In addition to the power supply, the power supply board may also contain features such as LED indicators to indicate the status of the power supply and connectors or terminals for connecting to other power supply components. Surveillance system.


Product Name

Edan IM8 patient monitor power supply board 21.53.112195012 PS900K


BrandEdan
Part No21.53.112195012
ApplicationEdan IM8 patient monitor
MOQOne piece
Voltage

00 V to 240 V~


Current1.0 A -0.5 A
FuseT3.15 AH250 VP
Power frequency

50 Hz/60 Hz



Maintenance Edan IM8 patient monitor power supply board 21.53.112195012 PS900K


To service the Edan IM8 patient monitor power supply, follow these steps:


Power Down: Before performing any maintenance, ensure that the power to the patient monitor is completely turned off. This not only means unplugging the monitor, but also the batteries.


Inspect the power board: Carefully inspect the power board for any visible signs of damage or wear. Look for loose connections, burnt parts or blown fuses. If any abnormalities are found, it may need to be repaired or replaced.


Clean the Power Plate: Remove dust and dirt accumulated on the Power Plate with compressed air or a soft brush. Be careful not to use liquid cleaners or solvents as they may damage the card components.


Check the connections: Carefully check all the connections on the power supply. Make sure they are tight and not loose. If you find any loose connections, gently tighten them. Avoid using excessive force as this may cause further damage.


Test the fuses: If the power supply has fuses, check them with a multimeter to make sure they are working properly. Replace blown or faulty fuses with suitable fuses.


Reassemble and Reconnect: After completing the maintenance steps, reassemble the power supply and reconnect it to the patient monitor. Double check that all connections are secure.


Power on and test: Reconnect the monitor to the power source and turn it on. Test the monitor to make sure it is working properly and that the AC adapter is providing a stable power supply.



Thank you so much for your attention .If you're interested in Power Supply Board 21.53.112195012 PS900K For Edan IM8 Patient Monitor ,feel free to contact us .Thank you .