H9N1 Bird Flu Veterinary Diagnostic Kits Antigen Coated Microplate For Personal

Categories Veterinary Test Kits
Brand Name: New Life
Model Number: 96 wells
Certification: ISO, CE
Place of Origin: China
MOQ: 10 kit
Payment Terms: T/T, Western Union
Supply Ability: 100000kit/month
Delivery Time: 20-35days
Packaging Details: 96T/kit
Method: Elisa
Format: 96T/KIT
Valid: 24 month
Accuracy: 99%
Sensitivity: 99%
Application: H9N1 Bird flu
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

H9N1 Bird Flu Veterinary Diagnostic Kits Antigen Coated Microplate For Personal

High accuracy Bird Flu H9N1 antibody ELISA Test kit, 96wells/kit,proffesional use


1. Brief


Bird flu (Avian influenza, AI) is an acute contact venereal toxicity infectious disease against the domestic poultry industry at present. Vaccination is the most effective way to prevent and control it, the antibody level after immune reflects the vaccine effect, which directly related to immune resistance to avian influenza virus in chicken flocks.

This product is applicable to the different species, different age in chicken serum specific antibody detection of H9N1. It can be used for H9N1 virus vaccine immune time of analysis, evaluation of immune effect, chickens with H9N1 in immune status.


2. Principle


The kit is based on an indirect enzymatic immunoassay(Indirect ELISA).The antigen is coated on plates. When a sample serum contains specific antibodies against virus, they will bind to the antigen on plates. Wash the unbound antibodies and other components. Then add a specific Enzyme conjugate. After incubation and washing, add the TMB substrate. A colorimetric reaction will appear, measured by a spectrophotometer (450 nm).


3. Components

1H9N1 antigen coated microplate96T×1
2Enzyme conjugate11ml×1
3Sample diluent50ml×1
4Substrate A6 ml×1
5Substrate B6 ml×1
620x Concentrated washing solution40 ml×1
7Positive control1.0 ml×1
8Negative control1.0 ml×1
9Stop solution6 ml×1
10Adhesive Foil1 piece
11Sealed bag1 piece
12Instruction1 piece

4. Sample preparation


1) Take animal whole blood, get serum by regular method, the serum need to be clear, no hemolysis, no pollution. For short-term storage, the sample can store at 2~8℃, for long-term storage, at -20℃.


2) Dilute serum with Sample diluent at 100 times (such as add 2μl serum into 198μl sample diluent, stir evenly). Positive control and Negative control do not need dilute.


3) Return the 20x Concentrated washing solution into room temperature (about 25℃) before use, shake to dissolve the precipitated salt, then dilute it with distilled water or deionized water at 20 times.


5. Test procedure


1) Return the kit to room temperature for 30mins before use.

2) Take the needed quantity microplate well, set 1 well of blank control well, 2 wells of negative control well, 2 wells of positive control well, seal the unused plate, store at 2~8℃.

3) Add 100ul sample diluent into blank control well. Add Negative control to negative control well, 100μl/well, Positive control to positive control well, 100μl/well; for sample well, add diluted serum 100μl/well;

4) Mix evenly, Incubation at 37 ℃ for 30 minutes.

5) Discard liquid of the wells and fill all wells with washing solution, incubate for 30s and discard. Repeat washing procedure 5 times as above, pat to dry.

6) Add enzyme conjugate to each well, 100μl/well.(Except blank control well)

7) Incubation at 37 ℃ for 30 minutes.

8) Wash as step 5).

9) Add Substrate A 50μl/well, then Substrate B 50μl/well, mix evenly, incubation at 37 ℃ in dark for 10 minutes.

10) Add stop solution 50μl/well, mix evenly, use ELISA Reader to measure A value at 450nm (630nm as reference) of each well.


6. Results


1) Negative control well: In normal, A value of negative control well ≤0.20;

2) Positive control well: In normal, A value of positive control well ≥0.60;

3) Calculation of C.O Value: C.O= 0.13 + Mean of Negative control well (Calculate as 0.07 when the mean of Negative control well is lower than 0.07)

4) Result judge:

When Sample A450 ≥C.O, the result is Positive;

When A450<c.o, the="" results="" is="" negative<="" p="">


7. Limitation


The kit can only detect H9N1 IgG antibody in chicken serum or plasma qualitatively. Make crude evaluation strong, medium and weak of antibody level based on A value.


8. Notes


1) Wear gloves and work clothes when operate, strictly sound and perform disinfection and isolation system.

2) The stop solution is corrosive, avoid touch skin and clothes, wash with tap water if touched.

3) Microplate removed from the refrigerated environment should be balance to dry at room temperature, and seal the unused microplate with desiccant.

4) Wash solution is easily crystallized at low temperature, to be returned to room temperature when used to dissolve.

5) Add Washing solution to each well fully, to prevent orifice free enzyme, which can not be washed

6) The test sample should be fresh.

7) Determination of the test results must be based on ELISA reader.

8) Never mix reagents from different batches.


ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry
Quality H9N1 Bird Flu Veterinary Diagnostic Kits Antigen Coated Microplate For Personal for sale
Send your message to this supplier
 
*From:
*To: Orient New Life Medical Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Find Similar Products By Category:
Inquiry Cart 0