High Accuracy Troponin I Test Kit Rapid Chromatographic Immunoassay 98% Accuracy

Categories Cardiac Blood Tests
Brand Name: New Life
Model Number: cassette
Certification: ISO13485,CE
Place of Origin: China
MOQ: 5000pcs
Payment Terms: T/T, Western Union
Supply Ability: 2000000pcs/month
Delivery Time: 20-30days
Packaging Details: 1pc/pouch, 25pcs/box
Category: Cardiac test
Format: cassette
Specimen: Whole Blood/Serum/Plasma
Testing time: 5-15 minutes
Shelf Life: 24 Months
Application: Troponin I
Accuracy: 98.9%
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

High Accuracy Troponin I Test Kit Rapid Chromatographic Immunoassay 98% Accuracy

High accuracy One Step Troponin I Rapid Diagnostic Test, diagnosis of myocardial infarction (MI),quickly


Intended Use:


The Troponin I Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of human cardiac Troponin I in whole blood, serum or plasma as an aid in the diagnosis of myocardial infarction (MI).


Test Principle:


The Troponin I Rapid Test Device (Whole Blood/Serum/Plasma) is a qualitative, membrane based immunoassay for the detection of cTnI in whole blood, serum or plasma. The membrane is pre-coated with capture reagent on the test line region of the test. During testing, the whole blood, serum or plasma specimen reacts with the particle coated with anti-cTnI antibodies. The mixture migrates upward on the membrane chromatographically by capillary action to react with capture reagent on the membrane and generate a colored line. The presence of this colored line in the test line region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.


TEST PROCEDURE


1. Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not open the pouch until ready

to begin testing.

2. Remove the device from the sealed pouch and lay it on a flat and dry surface.

3. Using the provided pipette, add one drop of fresh specimen to the sample well.

4. Hold the buffer bottle vertically and add 1 drop to the sample well. /If using a pipette, change a new one to avoid cross-contamination. Draw and transfer 2-3 drops of buffer to the sample well.

5. Read the result between 15-20minutes. Do not read results after 20 minutes.


INTERPRETATION OF RESULTS


POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).


*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of TP antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.


NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.


PERFORMANCE CHARACTERS:


Sensitivity and Specificity


The Troponin I Rapid Test Device (Whole Blood/Serum/Plasma) has been evaluated with a leading commercial cTnI EIA test using clinical specimens. The results show that the sensitivity of the Troponin I Rapid Test Device (Whole Blood/Serum/Plasma) is 98.3% and the specificity is 98.4% relative to the leading EIA test.


Troponin I Rapid Test Device vs. EIA


MethodEIA Test

Total

Results

Troponin I Rapid Test DeviceResultsPositiveNegative
Positive1136119
Negative2493495
Total Results115499614

Relative Sensitivity: 98.3%(93.9%-99.8%)*

Relative Specificity: 98.4%(97.4%-99.6%)*

Accuracy: 98.7%(97.5%-99.4%)*

*95% Confidence Interval


ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry
Quality High Accuracy Troponin I Test Kit Rapid Chromatographic Immunoassay 98% Accuracy for sale
Send your message to this supplier
 
*From:
*To: Orient New Life Medical Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0