5ppm Infrared SF6 Air Purity Sensor 0-90%RH

Categories Gas Detector Sensor
Brand Name: Kacise
Model Number: KSS532
Place of Origin: shanxi xi'an
MOQ: 1
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1000 Pieces per Week
Delivery Time: 5 work days
Packaging Details: each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Storage Temperature: -20-80℃
Operating Temperature: -20-60℃
Operating Humidity: 0-90%RH
Work Pressure: 0.8-1.2 atm
Supply Voltage: 12V
Maximum Operating Current: 120mA
Detection Range (customizable).: 1500ppm
Resolution: 5ppm
Measurement Accuracy: ± 30ppm or ±5% true value is the greater
T90 Pipeline Type of Pump suction: 5S
T90 Pipeline Type of Diffusion: 30S
Repeatability of Zero: Less than ±50
Repeatability of Range: Less than ±5%.
Life Span: 5-10 years
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

5ppm Infrared SF6 Air Purity Sensor 0-90%RH

KSS532 Infrared SF6 Purity Sensor


1. Overview

KSS532 is a gas sensor module using NDIR infrared absorption detection principle, which determines the concentration according to the absorption of SF6 gas at 10.6um. KSS532 adopts MEMS light source, optical cavity with special structure and dual-channel detector to realize space dual optical path reference compensation, and microprocessor for signal acquisition, processing and output. KSS532 has good selectivity, high sensitivity, no oxygen dependence, long life, low power consumption; Built-in temperature sensor for temperature compensation; At the same time, it has UART and 485 output, which is convenient for customers to apply various applications.


2. Technical parameters


parametersymbolminimumTypical valuesmaximumunit
Storage TemperatureTstg-20-80°C
Operating TemperatureTA-2060°C
Operating HumidityHA090% RH
Work PressurePA0.81.2atm
Supply VoltageVs111230V
Maximum Operating CurrentIavg100120150mA
Detection Range (customizable).Ra1500ppm
ResolutionResolution5ppm
Measurement AccuracyAcurracy± 30 or ±5% true value is the greater%vol
T90 Pipeline TypePump suction5second
Diffusion30second
RepeatabilityZeroLess than ±50ppm
RangeLess than ±5%.
Life Span510year

3. Structural Dimension Drawing

Unit: mm


KSS532 block diagram (diffusion and pumping compatible).


Pump suction type: length * width * height: 61mm * 40mm * 32mm

Diffusion type: length * width * height: 61mm * 40mm * 18mm


4. Installation instructions

The sensor mounting positioning hole is installed according to the structural dimension drawing, and the aperture is 3.2mm.

The wiring socket spacing is 2.54 m m.


5. Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, not more than 3 months is recommended.

Do not use the sensor for a long time in an environment with a high density of dust.

Please use the sensor within the range of the sensor's power supply.


6. Ordering Instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name

2) Measure the gas

3) Sensor range

For example, SW320D, SF6, 0-5000 ppm


7. Order Information


Order information sheet
KSS532KSS532 CO2 concentration sensor
xxxxThe sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000Range 200ppm (default).
10000Range 10000ppm
50000Range 50000ppm
encodeThe reaction speed is divided into two types: fast and slow
SSlow (default).
Qfast
encodeBaud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
CustomConfirm the baud rate before ordering
24002400bps baud rate
96009600bps baud rate
1920019200bps baud rate
3840038400bps baud rate (default)
encodeSerial port protocol
Modbus-RTUStandard Modbus-RTU protocol (default).
Modbus-ASCIIStandard Modbus-ASCII protocol
Modbus-SelfModbus private protocol
KSS532-2000-S-38400-Modbus-RTU

8. Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China


Appendix


ShorthandFull name
VOL1% VOL refers to 1% of the volume of a particular gas in air.
PPM1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2Oxygen molecules
LCDLCD display
RS485Asynchronous serial port 485
DCdirect current
ACCommunication
PVCpolyvinyl chloride