UL 2594 Clause 8.2 Figure 6 Articulated Probe Nylon And Metal Material

Categories EVSE Testing Equipment
Brand Name: Sinuo
Model Number: SN2210-35
Certification: Calibration Certificate (Cost Additional)
Place of Origin: China
MOQ: 1
Price: Negotiation
Payment Terms: T/T
Supply Ability: 100 pcs/month
Delivery Time: 3 days
Packaging Details: Aluminium box and carton box
Applied Standard: UL 2594
Applied Clause: Clause 8.2
Applied Figure: Figure 6
Probe Feature: Joint probe
Test Sample: Live/mechanical parts
Probe Material: Nylon and metal
Test Function: Enclosure Protection
Package type: Aluminium box
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

UL 2594 Clause 8.2 Figure 6 Articulated Probe Nylon And Metal Material


UL 2594 Clause 8.2 Figure 6 Articulate Probe


Equipment Overview for UL 2594 Clause 8.2 Figure 6 Articulate Probe



Standard:UL 2594 clause 8.2 figure 6.

Application:It is widely used in the enclosure protection test of the electrical equipment.

Test sample: Easily accessible enclosure live parts or mechanical parts.

Feature: Nylon handle + probe, it is manufactured according to the standard figure.

Technical Parameters for UL 2594 Clause 8.2 Figure 6 Articulate Probe


Probe materialStainless steel
Handle materialNylon
Applied forceWithout built-in force, should work with a force gauge
Applied standardsUL 2594 Clause 8.2 Figure 6

Description of Relevant Standards for UL 2594 Clause 8.2 Figure 6 Articulate Probe



8 Protection of Users- Accessibility and User Servicing


8.1 General


8.1.1 The requirements in this section apply to parts that are accessible to the user. For protection of servicepersonne requirements, refer to Protection of Service Personnel, 32.


8.2 Accessibility


8.2.1 To reduce the risk of unintentional contact that results in electric shock from an uninsulated live part or film-coated wire, an opening in an enclosure shall comply with either:


a)For anopeningthat has a minor dimension less than 25.4 mm (1 inch). such a part or wire shall not be contacted by the probe illustrated in Figure 6.or


b)Foran opening that has a minor dimension of 25.4 mm (1 inch) or more, such a part or wire shall be spaced from the opening as specified in Table 8.


Table 8

Minimum required distance from an opening to a part that involves a risk of electric shock
Minor dimension of opening a, bMinimum distance from opening to part b
mminchesmminches
25.4(1)165.0(6-1/2)
31.8(1-1/4)190.0(7-1/2)
38.1(1-1/2)318.0(12-1/2)
47.6(1-7/8)394.0(15-1/2)
54.0(2-1/8)444.0(17-1/2)
c762.0(30)

a See 8.2.4

b Between 19.1 and 54 mm (3/4 and 2-1/8 inches), interpolation is to be used to determine a value between values specified in the table.

c More than 54 mm (2-1/8 inches), and not more than 152.0 mm (6 inches).