Wall Mounted O3 Detector Ozone Gas Concentration Analyser Absorption Of Uv Light

Categories Exhaust Gas Analyzer
Brand Name: Zetron
Model Number: UVOZ-3300C
Certification: CE, ISO13485, ISO9001
Place of Origin: China
MOQ: 1
Payment Terms: T/T, L/C, Western Union, MoneyGram
Supply Ability: 10000 set/month
Delivery Time: 3-7 days
Packaging Details: paper carton
Model: UVOZ-3300C
Measuring range: 0-300g/Nm3
Gas flow: 0.5L ± 0.2L/min
Ambient temperature: -20 to 50°C
Dimensions: 230mm (H) x 330mm (W) x 150mm (D)
Warranty: 1 year
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Wall Mounted O3 Detector Ozone Gas Concentration Analyser Absorption Of Uv Light

UVOZ-3300C Ozone Gas Analyser

OVERVIEW

The UVOZ-3300C ozone gas analyser calculates the current ozone concentration by measuring the change in light signal intensity before and after ozone absorption of UV light. The equipment uses an advanced dual-light UV light source system with an intelligent lamp management system, which enables the UV lamp to reach the measurement state quickly after switching on. It is mainly used for continuous detection of ozone gas in various industrial environments, and can also be used to detect ozone gas in operating pipelines, vessels and other environments. It is widely used in pharmaceutical, chemical, municipal and wastewater treatment industries for the measurement of ozone generator outlet concentration and ozone generator output.
The ozone analyser has a touch screen operator interface with real time display of ozone gas concentration, with pressure and temperature compensation and display, and can be set for automatic zero time and manual zeroing mode. High concentration (g/Nm3) range with flow input and real time display of ozone generator output. Two sets of relay signal outputs are available, allowing the user to choose between high and low alarm point signal output connections. The core component adopts UV long life light source system with high transmittance quartz sheet to ensure the stability of the zero point and prevent the zero point drift from affecting the accuracy of the detection concentration. According to the foreign light cell technology design of pressure-resistant, impact-resistant independent light cell structure, zero calibration operation gas flow, pressure, flow rate remains unchanged, to prevent the impact of airflow on the zero calibration, without closing the ozone inlet can complete the zero calibration operation, to ensure that the equipment can be 24 hours a day continuous operation.

FEATURES

Measurement features: patented process with automatic zero correction, dual-optical UV absorption method principle, foreign long-life UV LED light source, continuous operation, ensuring the stability of the detection concentration.
Test method: Dual-optical UV absorption method, long-life light source system, high measurement accuracy
Measurement principle: accurate measurement by photometric absorption principle according to Lambert-Beer's law.
Light source system: foreign long-life UV light source system (UV LED light source (with lens)), free 2-year guarantee.
Usage: Indoor installation with power and signal terminals.
Light cell system: Separate light cell technology, no leakage, high pressure resistance, high flow sampling gas impact resistance.
Intelligent compensation: built-in temperature and pressure compensation and display, with automatic compensation of the light source.
Operation mode: User can choose between manual zero calibration and automatic zero calibration according to the operating status, and can set the automatic zero calibration time.
Display units: g/Nm3, mg/NL optional.
Data display: HD colour touch screen, high concentration range setting for incoming gas mass flow, real time display of yield (optional).
Output functions: 4-20mA, RS485 communication, two sets of alarm point output, electronic flowmeter input, etc.
Standard equipment: anti-corrosion flow meter, ozone tail gas destroyer, inlet gas filter.


PARAMETER

ModelUVOZ-3300C
Measuring range0-300g/Nm3
Optional ranges0-200g/Nm3, 0-100g/Nm3, 0-50g/Nm3, 0-1000ppm
Light source lifeapprox. 30,000 - 50,000 hours
Sampling methodpositive pressure sampling, negative pressure sampling (optional)
Display interface4.3" touch screen operator interface
Content interfaceozone concentration, temperature, pressure
Auxiliary functionsTemperature compensation, pressure compensation
Display unitsg/Nm3, mg/NL, %WT optional
Display resolution0.01g/Nm3
Gas flow0.5L ± 0.2L/min
Input pressure<0.1 MPa
Concentration error0.5% FS max
Linearity error0.5% FS max
Zero point drift<±0.3%.FS
Response time0.03 s for signal, 0.3 s for display
Ambient temperature-20 to 50°C
Piping connectionQuick screw (stainless steel)
Tandem sample apertureΦ8 (8mm*6mm) (optional)
Bypass sampling apertureΦ6 (6mm*4mm)
Communication methodRS-485
Output mode4-20mA (active)
Relay signalrelay signal for high alarm point, relay signal for low alarm point
Power supplyAC 110-220V
Dimensions230mm (H) x 330mm (W) x 150mm (D)
Note1mg/L = 1g/m3 = 467PPM.
Free warranty24 months (mainframe sensor)


TAG

Ozone gas analyser,Ozone detector,Gas concentration analyzer,Ozone monitor,Ozone concentration detector, OEM/ODM service.

Quality Wall Mounted O3 Detector Ozone Gas Concentration Analyser Absorption Of Uv Light for sale
Send your message to this supplier
 
*From:
*To: Beijing Zetron Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0