500-750gpm 60-100m Head Fire Water Booster Pump Diesel Engine Driven Fire Water Pump

Categories Fire Fighting Water Pump
Brand Name: SANCHANG
Model Number: COS-F80-270
Certification: ISO9001
Place of Origin: CHINA
MOQ: 1 pcs
Price: Negotiated
Payment Terms: L/C, T/T
Supply Ability: 300pcs/month
Delivery Time: 45 working days
Packaging Details: Plywood Case
Flow Capacity: 500-750gpm
Delivery Head: 60-100m
Inlet/Outlet Dia.: DN125/DN80mm
Working Pressre: <1.5MPa
Liquid Temperature: 0-80 ℃
Application: Clean water, Sewage, Hot water, Corrosive liquid, Mining water
Material: Cast Iron, Cast Steel, S.S304, S.S316, Duplex S.S2205
Driven By: Electric Motor / Diesel Engine
Voltage: 380V/415V/440V/460V/660V
Speed: 2980/3560rpm
Seal: Gland packing/Mechanical seal
Frequency: 50 /60 Hz
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

500-750gpm 60-100m Head Fire Water Booster Pump Diesel Engine Driven Fire Water Pump

Double Suction Split Case Fire Fighting Water Pump COS-F80-270 (500-750gpm 60-100m)


Description

A fire fighting water pump is a centrifugal pump which is used for pumping fire-fighting water. Fire-fighting pumps can be designed for transportable use (e. g. on fire-fighting vehicles or as portable fire pumps) or for stationary use (e. g. hydrants, sprinkler systems).


The XSF series Horizontal Split Case Fire Fighting Water Pumps are engineered for reliable operation upon stationary use. All fabricated parts are standardized and accurately machined for true alignment, increasing overall durability. Precision balancing of all rotating components provides mechanical dependability, reliable operation and minimal maintenance. Impellers are constructed with double inlets that practically eliminated end thrust while boosting operating efficiency.

Fire fighting water pumps are usually in idle status. They are only operated for testing water / water mist systems or foam systems, and in the event of fire. This is why reliable start-up and fast ramp-up to full pump power output (also after prolonged standstill) is of particular importance.

Features
* Stainless steel impellers and shaft as standard
* Comply to FM and/or UL standards (NFPA 20, UL448 and FM1311)


High efficiency
The shapes of impeller and pump casings are optimized to achieve the highest possible efficiency for the specific design flow rate and pressure head. Off design characteristics are optimized to give each pump a wide operating range, ensuring that cavitation limits are not exceeded.


Ease of maintenance
The pumps are easy to maintain as the upper half can be removed without dismantling pipe connections and driver components so that the alignment is not disturbed. In addition, our service department offers financially attractive service and maintenance contracts, which guarantee that downtime in pumping installations is kept to a minimum.


Durability
By using double suction impellers and double volute casings Sanchang supplies pumps with low vibration and noise levels. A double volute reduces radial thrust, resulting in longer service life for bearings and seals.


Parameters of COS-F series Split Case Fire Fighting Water Pump

Flow Capacity500-750 gpmDelivery Head60-100 m
Inlet/Outlet Dia.DN125/DN80 mmWorking Pressure≤ 1.5 MPa
Liquid Temperature0 - 80 ℃Driven ByElectric Motor / Diesel Engine
Seal TypeMechanical seal / Gland packingLiquidClean water or similar
Material of ConstructionCast Iron / Cast Steel / S.S304 / S.S316 / Duplex S.S2205


Applications

Industrial fire fighting system,
Residential fire fighting system,
Commercial fire fighting system,
Ware house fire fighting system,
Boat & Sea platform fire fighting,

Factory fire fighting system.


Main Parts Configuration

To meet the NFPA20 standards, the pump was constructed with the following materials:

Parts NameMaterial of Construction (Comply with NFPA20)
Pump CaseDuctile Iron
Shaft40Cr / 35CrMo / 42CrMo/S.S420
Shaft SleeveS.S304
ImpellerS.S304/Bronze
Wearing RingS.S304/Bronze
BearingChina Make/NSK/SKF
SealsPTFE Packing Seals/Mechanical Seals
We offer a variety of service activities
• Online Supporting before & after sales, on-site consulatin include installation & commissioning advices.
• Original spare parts - we provide stock control of spare parts for groups of pumps (total care maintenance). We are able to respond quickly and flexibly thanks to the availability of our own foundry.
• Witness Inspection & Performance testing in factory.
• Training of our worldwide customers in the field of installation, operation and maintenance.
Quality 500-750gpm 60-100m Head Fire Water Booster Pump Diesel Engine Driven Fire Water Pump for sale
Send your message to this supplier
 
*From:
*To: CHANGSHA SANCHANG PUMP CO., LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0