IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device

Categories Flammability Test Chamber
Brand Name: Sinuo
Model Number: SN775
Certification: Calibration Certificate (Cost Additional)
Place of Origin: China
MOQ: 1
Price: Negotiable
Payment Terms: T/T, L/C, Western Union, MoneyGram
Supply Ability: 10 Sets Per Month
Delivery Time: 20 Days
Packaging Details: Plywood
Ambient temperature: 10℃~35℃
Relative humidity: 30%~90%
Burner opening: Φ7±0.05mm
Burning Time: 9999X0.1S
Burning Angle: Tilt 45°±2°
Power supply: AC220V±10%, 50/60Hz
Inner flame: 55±5mm
Outer flame: 180±10mm
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device


IEC60332-1-2 Single Insulated Wire Vertical Flammability Test Apparatus For Single Electric Cable Test


Overview:

The flammability chamber testing adopts integral type inlet ignition system, the combustion time delays 0.1s thus to ensure the sufficient time for gas burning. It also has matte black background, multi-functional flame measure gauge, full stainless steel chamber body, large observation window, imported high precision digital indicator, nice appearance. It is suitable for vertical burning test of a single electric wire, cable or optical fibre cable to determine the burning characteristics of its insulating material.



Principle:

The flame test apparatus meets the requirements of :
IEC 60332-1-1 “Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus”

IEC 60332-1-2 “Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame”

IEC 60332-1-3 “Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for determination of flamingdroplets/particles”
and etc.

Test principe: Integral air-intake automatic ignition system is adopted, and the combustion delay is only 0.1 seconds to ensure full combustion of gas.


Technical parameters:


Use EnvironmentPower supply: single-phase AC220V±10%, 50/60Hz
Ambient temperature: 10℃~35℃ Relative humidity: 30%~90%
Control operation modeElectrical control, button operation (PLC control can be optional)
Blast burner standardIEC60695-11-2 Annex A, Burner opening:Φ7±0.05mm,made of brass
Gas flow and gas category

Mixture gas: 650±30mL/min propane &10±0.5L/min air.
Dual flow meter adjustment

Flame application time9999X0.1S
Flame application angle

Tilt 45°±2°, Adjustable

Test flame calibrationTemperature measuring copper head: 500W: Ф9mm±0.01mm, weight before drilling:10 ± 0 .05g
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100°C

Distance between the bunsen burner port to temperature measuring copper block:95 mm

Flame height: Inner flame:55±5mm, outer flame:180±10mm
Temperature rise time from 100±5°C to 700°±3°C 45±5s
Combustion chamberWDH=300×450×1200±25mm
Test sampleLength: 600±25mm, distance from the bottom:50mm
Fixed horizontal support of the sample2, distance:550mm
Overall dimensionsWDH=700×450×1350mm, weight about 120kg
How to position of test piece?
The test piece shall straightened and secured to two horizontal supports by means of a suitable size of copper wire, in a vertical position in the centre of the metal, so that the distance between the bottom of the upper support and the top of the lower support is (550±5)mm. In addition, the best piece shall be positioned so that the bottom of the specimen is approximately 50mm from the base of the enclosure. The vertical axis of the test piece shall be arranged centrally within the enclosure (i.e. 150mm from each side and 225mm from the rear).
Sinuo techincal team well understand flammability testing requirements. Except supply various flammability test chamber , Sinuo can also have the ability to provide solutions for building the entire combustion laboratory. Sinuo team can well plan the the combustion laboratory's equipment layout , ventilation and exhaust, gas pipeline, safety measures, etc.