MPO Cable, MTP Cable, Data Center Ultra Low Loss Link Products,
Ultra Low Loss, Long Transmission Application
As global IP traffic grows rapidly and broadband Internet
technology continues to improve, there is rising demand for
transmission capacity and communications network, especially
400G/1000G technology, which also brings high requirements for
optical fiber transmission featuring multi-node, low loss, ultra
long distance, high capacity and high speed.
Traditional low loss fiber optic system can no longer coordinate
the application of data center multi-node management architecture,
so TC's ultra low loss optical link products, manufactured by super
Class-A high precision devices and innovative processes, are the
optimal choice. They are mainly used in multi-node structured
cabling projects, and far exceed the standards such as IEC 61754 and IEC 61755.
Product Features
Optical links in data centers typically consist of multiple MPO
nodes, LC nodes, and fiber optic cables. Compared to traditional
ones, TC's ultra low loss FO products enjoy a significant drop in the
total loss.
The maximum loss of ultra low loss MPO nodes reduces from 0.35dB to about 0.25dB, about 28% performance
improvements; while LC nodes reduces from 0.2dB to about 0.1dB, resulting in about 50% performance
improvements. The more losses saved, the more flexibility provided for cabling
management. For example,
When using multimode OM3 fiber transmission of more than 100G, the
total loss value of the entire link requires IL<1.8dB, which
means that the loss of fiber optic cable in 100m standard link
reaches about 0.35dB, left less than 1.45dB to connection nodes.
That is, traditional low loss products can only support 4 MPO nodes
(or corresponding MPO&LC node combinations, such as 2*MPO nodes
+ 3*LC nodes), greatly reducing flexibility and manageability of
data center cabling. However, with TC's ultra low loss products, the entire optical link can hold about 6 MPO nodes or up to 15 LC
nodes and their combinations, thus bringing more convenience to node management in EDA, IDA,
HDA.
Therefore, customers can acquire both speed and manageability with
TC's ultra low loss products.
Application Standards
GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2
Technical Details
| Specifications | MPO Patch Cords | MPO-LC Fanout Patch Cords | LC-LC Fanout Patch Cords |
Singlemode | Length | L≤3m | L>3m | L≤3m | L>3m | L≤3m | L>3m |
Connector Type | MPO-MPO | MPO-MPO | MPO-LC | MPO-LC | LC-LC | LC-LC |
Grinding Type (front) | MPO APC 8˚ | MPO APC 8˚ | MPO APC 8˚ | MPO APC 8˚ | LC PC0˚ | LC PC0˚ |
Grinding Type (end) | MPO APC 8˚ | MPO APC 8˚ | LC PC0˚ | LC PC0˚ | LC PC0˚ | LC PC0˚ |
Testing Method | Method B | Method B | Method C | Method C | Method B | Method B |
Insertion Loss IL (Typical) | ≤0.10dB | —— | ≤0.12dB | —— | ≤0.04dB | —— |
Insert Loss IL (Max.) | ≤0.35dB | ≤0.35+0.0004×LdB | ≤0.35dB | ≤0.45+0.0004×LdB | ≤0.10dB | ≤0.15+0.0004×LdB |
Return Loss RL (Min.) | ≥60dB | ≥60dB | —— | ——— | ≥50dB | ≥50dB |
Connectivity Method | A/B/C | A/B/C | straight/cross | straight/cross | straight/cross | straight/cross |
Multimode | Length | L≤3m | L>3m | L≤3m | L>3m | L≤3m | L>3m |
Connector Type | MPO-MPO | MPO-MPO | MPO-LC | MPO-LC | LC-LC | LC-LC |
Grinding Type (front) | MPO PC 0˚ | MPO PC 0˚ | MPO PC 0˚ | MPO PC 0˚ | PC 0˚ | PC 0˚ |
Grinding Type (end) | MPO PC 0˚ | MPO PC 0˚ | LC PC0˚ | LC PC0˚ | LC PC0˚ | LC PC0˚ |
Testing Method | Method B | Method B | Method C | Method C | Method B | Method B |
Insertion Loss IL (Typical) | ≤0.08dB | —— | ≤0.10dB | —— | ≤0.06dB | —— |
Insert Loss IL (Max.) | ≤0.2dB | ≤0.3+0.0035×LdB | ≤0.25dB | ≤0.40+0.0035×LdB | ≤0.10dB | ≤0.15+0.0035×LdB |
Return Loss RL (Min.) | ≥30dB | ≥30dB | —— | —— | ≥30dB | ≥30dB |
Connectivity Method | A/B/C | A/B/C | straight/cross | straight/cross | straight/cross | straight/cross |
| Specifications | MPO Patch Cords | MPO-LC Fanout Patch Cords | LC-LC Fanout Patch Cords |
Singlemode | Length | L≤3m | L>3m | L≤3m | L>3m | L≤3m | L>3m |
Connector Type | MPO-MPO | MPO-MPO | MPO-LC | MPO-LC | LC-LC | LC-LC |
Grinding Type (front) | MPO APC 8˚ | MPO APC 8˚ | MPO APC 8˚ | MPO APC 8˚ | LC PC0˚ | LC PC0˚ |
Grinding Type (end) | MPO APC 8˚ | MPO APC 8˚ | LC PC0˚ | LC PC0˚ | LC PC0˚ | LC PC0˚ |
Testing Method | Method B | Method B | Method C | Method C | Method B | Method B |
Insertion Loss IL (Typical) | ≤0.10dB | —— | ≤0.12dB | —— | ≤0.04dB | —— |
Insert Loss IL (Max.) | ≤0.35dB | ≤0.35+0.0004×LdB | ≤0.35dB | ≤0.45+0.0004×LdB | ≤0.10dB | ≤0.15+0.0004×LdB |
Return Loss RL (Min.) | ≥60dB | ≥60dB | —— | ——— | ≥50dB | ≥50dB |
Connectivity Method | A/B/C | A/B/C | straight/cross | straight/cross | straight/cross | straight/cross |
Multimode | Length | L≤3m | L>3m | L≤3m | L>3m | L≤3m | L>3m |
Connector Type | MPO-MPO | MPO-MPO | MPO-LC | MPO-LC | LC-LC | LC-LC |
Grinding Type (front) | MPO PC 0˚ | MPO PC 0˚ | MPO PC 0˚ | MPO PC 0˚ | PC 0˚ | PC 0˚ |
Grinding Type (end) | MPO PC 0˚ | MPO PC 0˚ | LC PC0˚ | LC PC0˚ | LC PC0˚ | LC PC0˚ |
Testing Method | Method B | Method B | Method C | Method C | Method B | Method B |
Insertion Loss IL (Typical) | ≤0.08dB | —— | ≤0.10dB | —— | ≤0.06dB | —— |
Insert Loss IL (Max.) | ≤0.2dB | ≤0.3+0.0035×LdB | ≤0.25dB | ≤0.40+0.0035×LdB | ≤0.10dB | ≤0.15+0.0035×LdB |
Return Loss RL (Min.) | ≥30dB | ≥30dB | —— | —— | ≥30dB | ≥30dB |
Connectivity Method | A/B/C | A/B/C | straight/cross | straight/cross | straight/cross | straight/cross |
| Specifications | HD96 Cassette | 1.6mm Ultra Thin Dulpex Patch Cord |
Singlemode | Length | 0.42 | L≤3m | L>3m |
Connector Type | MPO-LC | LC-LC | LC-LC |
Grinding Type (front) | MPO APC 8˚ | LC PC0˚ | LC PC0˚ |
Grinding Type (end) | LC PC0˚ | LC PC0˚ | LC PC0˚ |
Testing Method | Method C | Method B | Method B |
Insertion Loss IL (Typical) | ≤0.15dB | ≤0.04dB | —— |
Insert Loss IL (Max.) | ≤0.35dB | ≤0.10dB | ≤0.15+0.0004×LdB |
Return Loss RL (Min.) | —— | ≥50dB | ≥50dB |
Connectivity Method | A/B/T | straight/cross | straight/cross |
Multimode | Length | 0.42 | L≤3m | L>3m |
Connector Type | MPO-LC | LC-LC | LC-LC |
Grinding Type (front) | MPO PC 0˚ | LC PC 0˚ | LC PC 0˚ |
Grinding Type (end) | LC PC0˚ | LC PC 0˚ | LC PC 0˚ |
Testing Method | Method C | Method B | Method B |
Insertion Loss IL (Typical) | ≤0.10dB | ≤0.04dB | —— |
Insert Loss IL (Max.) | ≤0.25dB | ≤0.10dB | ≤0.15+0.0035×LdB |
Return Loss RL (Min.) | —— | ≥30dB | ≥30dB |
Connectivity Method | A/B/T | straight/cross | straight/cross |
| Specifications | HD96 Cassette | 1.6mm Ultra Thin Dulpex Patch Cord |
Singlemode | Length | 0.29 | L≤3m | L>3m |
Connector Type | MPO-LC | LC-LC | LC-LC |
Grinding Type (front) | MPO APC 8˚ | LC PC0˚ | LC PC0˚ |
Grinding Type (end) | LC PC0˚ | LC PC0˚ | LC PC0˚ |
Testing Method | Method C | Method B | Method B |
Insertion Loss IL (Typical) | ≤0.15dB | ≤0.04dB | —— |
Insert Loss IL (Max.) | ≤0.35dB | ≤0.10dB | ≤0.15+0.0004×LdB |
Return Loss RL (Min.) | —— | ≥50dB | ≥50dB |
Connectivity Method | A/B/T | straight/cross | straight/cross |
Multimode | Length | 0.29 | L≤3m | L>3m |
Connector Type | MPO-LC | LC-LC | LC-LC |
Grinding Type (front) | MPO PC 0˚ | LC PC 0˚ | LC PC 0˚ |
Grinding Type (end) | LC PC0˚ | LC PC 0˚ | LC PC 0˚ |
Testing Method | Method C | Method B | Method B |
Insertion Loss IL (Typical) | ≤0.10dB | ≤0.04dB | —— |
Insert Loss IL (Max.) | ≤0.25dB | ≤0.10dB | ≤0.15+0.0035×LdB |
Return Loss RL (Min.) | —— | ≥30dB | ≥30dB |
Connectivity Method | A/B/T | straight/cross | straight/cross |