Product Name: 200W Ac Dc Enclose Type Power Supply
Input voltage: 176 - 264VAC
Output voltage: 12V/15V/24V/36V/48
Ultra low standby power consumption: < 0.75W @230VAC
Efficiency: ≥87%
Output type: Single
Dimension: 179.00 x 99.00 x 30.00 mm
Weight: 520g (Typ.)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

200W LED Street Light AC DC Enclosed Power Supply IEC 61000-4 EMC Performance


200W Enclosed Ac Dc Power Supply industrial control power supply


Descriptions


LM200-12Bxx series is one of Mornsun’s enclosed AC-DC switching power supply.It features AC input and at the same time accepts DC input voltage,cost-effective,low no load power consumption,high efficiency and high reliability.These power supply offer excellent EMC performance and meet IEC/EN61000-4,CISPR32/EN55032,UL/EN/IEC62368,EN60335,GB4943 standards and they are widely used in areas of industrial,LED,street light control,electricity,security,telecommunications,smart home etc


Features

  • AC input range: 176 - 264VAC
  • DC input range: 240 - 370VDC
  • Ultra low standby power consumption: < 0.75W @230VAC
  • Operating ambient temperature range: - 30℃ to +70℃
  • High efficiency, high reliability
  • LED indicator for power on
  • Output short circuit, over-current, over-voltage, over-temperature protection
  • UL/EN/IEC62368, EN60335, EN61558, GB4943 safety
  • Operating altitude up to 5000m

Specifications

Selection Guide

Certification


Part No.*

Output Power(W)

Nominal Output

Voltage and Current (Vo/Io)

Output Voltage

Adjustable Range (V)

Efficiency at 230VAC (%) Typ.

Max.

Capacitive Load (µF)

Steady statetransient*

UL/CE/CB/CQC

LM200-12B051502005V/30A4.5-5.58710000
LM200-12B12204--12V/17A10.2-13.887.54000
LM200-12B15210--15V/14A13.5-18883300
LM200-12B24211.2--24V/8.8A21.6-28.888.51500
LM200-12B36212.4--36V/5.9A32.4-39.6891500
LM200-12B48211.2--48V/4.4A43.2-52.889.5470
Note: 1.*Use suffix “C” for terminal with protective cover and suffix “Q” for conformal coating; 2.*Hold-up time1min (Typ.).
Input Specifications
ItemOperating ConditionsMin.Typ.Max.Unit
Input Voltage Range (by switch)AC input176--264VAC
DC input240--370VDC
Input Voltage Frequency47--53Hz
Input Current230VAC--2.23

A

Inrush Current230VACCold start--6080
Hot PlugUnavailable
Output Specifications
ItemOperating ConditionsMin.Typ.Max.Unit

Output Voltage Accuracy


Full load range

5V--±3--

%

12V--±1.5--
15V/24V/36V/48V--±1--
Line RegulationRated load--±0.5--
Load Regulation0% - 100% load5V--±2--
12V--±1--
15V/24V/36V/48V--±0.5--
Output Ripple & Noise*20MHz bandwidth (peak-to-peak value)5V/12V/15V/24V--150--mV
36V/48V--200--
Temperature Coefficient----±0.03%/℃
Minimum Load0----%
Stand-by Power Consumption230VAC, 25℃----0.75W
Hold-up Time230VAC16----ms
Short Circuit ProtectionRecovery time <5s after the short circuit disappear.Hiccup, continuous, self-recover
Over-current Protection110% - 185% Io, self-recover

Over-voltage Protection

5V≤8VDC (Output voltage turn off, re-power on for recover)
12V≤18VDC (Output voltage turn off, re-power on for recover)
15V≤22VDC (Output voltage turn off, re-power on for recover)
24V≤33.6VDC (Output voltage turn off, re-power on for recover)
36V≤46.8VDC (Output voltage turn off, re-power on for recover)
48V≤60VDC (Output voltage turn off, re-power on for recover)
Over-temperature ProtectionOutput voltage turn off, re-power on for recover

Note: *The “Tip and barrel method” is used for ripple and noise test, output parallel 47uF electrolytic capacitor and 0.1uF ceramic capacitor, please refer to

Enclosed Switching Power Supply Application Notes for specific information.

15V/24V/36V/48V--±0.5--
Output Ripple & Noise*20MHz bandwidth (peak-to-peak value)5V/12V/15V/24V--150--mV
36V/48V--200--
Temperature Coefficient----±0.03%/℃
Minimum Load0----%
Stand-by Power Consumption230VAC, 25℃----0.75W
Hold-up Time230VAC16----ms
Short Circuit ProtectionRecovery time <5s after the short circuit disappear.Hiccup, continuous, self-recover
Over-current Protection110% - 185% Io, self-recover

Over-voltage Protection

5V≤8VDC (Output voltage turn off, re-power on for recover)
12V≤18VDC (Output voltage turn off, re-power on for recover)
15V≤22VDC (Output voltage turn off, re-power on for recover)
24V≤33.6VDC (Output voltage turn off, re-power on for recover)
36V≤46.8VDC (Output voltage turn off, re-power on for recover)
48V≤60VDC (Output voltage turn off, re-power on for recover)
Over-temperature ProtectionOutput voltage turn off, re-power on for recover

Note: *The “Tip and barrel method” is used for ripple and noise test, output parallel 47uF electrolytic capacitor and 0.1uF ceramic capacitor, please refer to

Enclosed Switching Power Supply Application Notes for specific information.

Mechanical Specifications
Case MaterialMetal (AL1100, SGCC)
Dimensions179.00 x 99.00 x 30.00 mm
Weight520g (Typ.)
Cooling MethodFree air convection

Dimensions and Recommended Layout



Quality 200W LED Street Light AC DC Enclosed Power Supply IEC 61000-4 EMC Performance for sale
Send your message to this supplier
 
*From:
*To: KHC Power Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0