ophthalmic fundus camera excellent optic ultra-high resolution
fully auto
ophthalmic fundus camera Reticam 3100 is a highly recognized and popular automatic fundus
imaging system around the world. Through dual camera imaging, image
control and feature recognition, eye XYZ 3D automatic positioning
is realized. Through CCD imaging feedback, the exposure is
measured, and the exposure intensity is automatically and
accurately determined, without the need for a doctor's complex
operation. By controlling the focusing step length according to the
image resolution, the image definition can be automatically
adjusted to obtain a clear and accurate fundus image and help
doctors make accurate judgments for patients.
ophthalmic fundus camera is very important for patients with
diabetes and hypertension. In order to prevent fundus lesions,
these patients should have regular fundus screening according to
the course of disease. With the development of technology,
non-dilated technology has improved the accessibility of fundus
disease screening due to its advantages of simple operation and
high efficiency. Meanwhile, it is also suitable for patients with
glaucoma and hypertension who are not suitable for dilated pupil
examination. Previously due to the role of dilatation agents, it is
possible that hypertension patients after the use of higher blood
pressure. Digital Fundus Camera RetiCam 3100 only takes 1.9 minutes
for non-dilatation photographic examination, which is very suitable
for emergency patients. This technology will have a profound impact
on the clinical treatment mode and examination mode.
Acquisition Modes | Digital Fundus Camera/mydriatic Anterior photography
/Red-free(optional)(FFA)/(FAF) |
Field View | 50° |
Working Distance | 35mm |
Minimum Pupil | ≥3.3mm |
Focus Modes | Manual/Auto |
Alignment Modes | Double dots auxiliary |
Exposure | Manual /Auto |
Photography | SLR Camera |
Image definition | 24 Megapixel |
Compensation | ±25D |
Fixation | External /Internal (any position available) |
DICOM 3.0 | Support |
Digital Fundus Camera in the world |
Brand | TOPCON(NW-400) | DRS | NEWVISION(RETICAM3100) |
operation | automatic(one key taking picutre)/manual | automatic(one key taking picutre)/manual | automatic(one key taking picutre)/manual |
Acquisition modes | fundus/anterior | fundus/anterior/red-free filter | fundus/anterior/red-free filter/FFA(optional)/FAF(optional) |
Filed of view | 45 degree | 40-45degree | 45-50degee |
Mosic degee | | 80 degree | 135degree |
Minimum pipil size | 3.3mm | 3.5mm | 3.3mm |
Resolution | above 18megapiexl | sensor size:5 megapixel sensor resoultion: 48 pixel/degree | above18 megapixel (24 megapixel optional ) |
Fixation | 9 internal + 1 outside fixaiton | 7 internal fixation | countless fixaiton, any position is available during range + 1
outside fixation |
Technology of focus | | | Dual camrea technology |
exposure ligh | standard | standard | new technology, more soft, one patient same eye can take picuture
consecutive with almost same performace |


Company Introduction

Focusing on the two major public health problems of adolescent
myopia and elderly ophthalmology, our company researches new
diagnostic and treatment equipment for ophthalmology, develops
low-cost applicable technology products, realizes
industrialization, reduces the cost of social medical and health
system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development
concept.We have a strong technical force, has been awarded 11 patents, and
obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect
after-sales service system to provide medical equipment with the
highest cost performance and meticulous service.