Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home > Water Treatment >

500LPH Drinking Water RO System FRP Manual Control For Pure Water

Categories Drinking Water Treatment System
Brand Name: Jufu
Model Number: JFRO-500L
Certification: ISO9001
Place of Origin: China
MOQ: 1 unit
Price: Negotiable
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time: 2-4 weeks
Packaging Details: Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.
RO frame: SUS304
Warranty: 1 Year
MOQ: 1 unit
Tank material: SS/FRP (optional)
Pipe material: U-PVC/Stainless steel (optional)
Desalination rate: ≥99.5%
Control valve: Manual/Automatic
Recovery rate: 50%
Country of origin: China
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

500LPH Drinking Water RO System FRP Manual Control For Pure Water

500LPH Drinking Water RO System FRP Manual Control For Pure Water


What is Drinking Water RO System?


Drinking water ro system is raw water by reverse osmosis system precision filter, granular activated carbon filter, activated carbon filter, compression, and then through the pressure of the pump, the use of reverse osmosis membrane pore size 1/10000 microns to make relatively high concentrations of water into the low concentration of water, and industrial pollutants, heavy metals, bacteria, viruses and other impurities mixed in the water of a large number of sufficient isolation, In order to achieve the physical and chemical indicators of drinking water and sanitation standards, pure water is the best choice for the body to replenish water quality.


Technical specifications of Drinking Water RO System


Model

JFRO-500L

Host Size

800x600x1600mm (can be customized)

Power

1.5KW

Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure

0.8-1.2MPa

Recovery Rate

50%

Designed Water Inlet

1000L/h

Outlet Flow

500L/h

Desalination Rate

≥99.5%

RO Frame

SUS304

Membrane Size

4040

Membrane Elements

DOW /Hydranautics/Troy/ Vontron (Optional)

Number of Membranes

2

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

Tank Material

SS/FRP (Optional)

Control Valve

Manual/Automatic

Control Valve Brand

FLECK/RUNXIN

Membrane Housing

SS/FRP (Optional)

Pipe Material

U-PVC, Stainless steel (Optional)


The working process of Drinking Water RO System


1. Preprocessing
2. Reverse osmosis
3. Post-processing
4. Cleaning
5. Electrical control



The separation capacity of drinking water ro system membrane technology?


Reverse osmosis is currently a relatively accurate liquid filtration technology. RO reverse osmosis membrane can retain inorganic molecules such as dissolved salts and organic compounds with molecular weight greater than 100. On the other hand, water molecules can freely pass through the RO membrane, and the removal rate of typical soluble salts is high.


RO system failure analysis table:


possible reasonpossible locationpressure dropProduct water flowsalt permeability
Metal oxideThe first sectionusually increasesdeclineusually increases
colloid foulingThe first sectionusually increasesdeclineusually increases
foulingThe last sectionincreasesdeclineincreases

Biofouling


any sectionusually declineincreasesIncrease

organic fouling


all sectionsnormaldeclineusually increases

Oxidizing agent (eg: Cl2)


The first part is the most serioususually declineincreasesIncrease
Surface wear (carbon particles,sludge)The first part is the most seriousdeclineincreasesIncrease

Cracks in O-rings or glued


randomusually declineusually declineIncrease
The recovery rate is too highall partsdeclineusually declineIncrease







FAQ:


1. What is the membrane material of drinking water reverse osmosis system?


Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis

Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.


2. What is the material of mechanical filter?

Carbon steel, stainless steel, fiberglass


3, multi-way control valve according to the control mode of those?

Manual control valve, automatic control valve

Multi - way control valve is divided into: filter valve and softening valve

Automatic control valve is divided into: time type and flow type.

Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.


Quality 500LPH Drinking Water RO System FRP Manual Control For Pure Water for sale
Send your message to this supplier
 
*From:
*To: Jufu Water Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0