Sign In | Join Free | My frbiz.com |
|
Categories | Pediatrics Instruments |
---|---|
Place of Origin: | China |
Brand Name: | SUCE |
Model Number: | HD03 |
Packaging Details: | Standard packing |
Supply Ability: | 5000 Set/Sets per Month Infant Phototherapy Unit |
Price: | $18990.00 - $2,000.00/Sets |
Certification: | CE,ISO13485 |
MOQ: | 1pc |
Payment Terms: | T/T, Western Union.Payoneer |
Delivery Time: | about 10 days |
Instrument classification: | Class II |
Name: | Fully Automated Clinical Chemistry Analyzer |
Product name: | Mindray auto chemistry analyzer Mindray BC-6200 |
Parameters: | 37 Reportable parameters,29 Research parameters,7Reportable parameters |
Mode: | CBC, CBC+DIFF, CBC+DIFF+RET, CBC+RET, RET |
Data storage capacity: | Up to 10,0000 results including numeric and graphical information |
Operating environment temperture: | 15℃~32℃ |
Humidity: | 30%~85% |
Technical parameter | ||||||||
Power supply | 110~240V±10% 50/60Hz±2% | |||||||
Input power | 70VA | |||||||
Radiant wave length | 450nm~480nm | |||||||
Phototherapy source adjust range | Up phototherapy :360~610mm down phototherapy:45mm(constant) | |||||||
Phototherapy source rotation angle range | 0~180° | |||||||
LED lamp lifetime | 20000 hours | |||||||
LED lamp quantity | Up phototherapy :17 down phototherapy: 36 | |||||||
Time accuracy | 1min/12hours | |||||||
Accumulate time range | Up phototherapy :0~19999hours down phototherapy:0~9999hours | |||||||
Count down time range | Up phototherapy:30min~48hours down phototherapy:30min~24hours | |||||||
Down phototherapy: distance between the phototherapy equipment and the effective surface area:50mm,effective surface area:300mm*210mm Max total irradiance for bilirubin:1800μW/cm2 The average total irradiance for bilirubin:1700μW/cm2 | ||||||||
Up phototherapy: the relation table of distance between the
phototherapy equipment and the effective surface,effective surface
area ,level and irradiance as follows: | ||||||||
Distance between the phototherapy equipment and the effective
surface area :36cm,effective surface area:50cm*30cm | level | High | middle | low | ||||
Ebi max (maximum total irradiance for bilirubin) | 2800μW/cm2 | 2000μW/cm2 | 800μW/cm2 | |||||
Ebi avg (The average total irradiance for bilirubin) | 2000μW/cm2 | 1400μW/cm2 | 620μW/cm2 | |||||
level | High | middle | low | |||||
Distance between the phototherapy equipment and the effective
surface area :50cm,effective surface area:60cm*30cm | Ebi max (maximum total irradiance for bilirubin) | 1620μW/cm2 | 1200μW/cm2 | 480μW/cm2 | ||||
Ebi avg (The average total irradiance for bilirubin) | 1415μW/cm2 | 1000μW/cm2 | 400μW/cm2 | |||||
Working condition of circumstance | Temperature range | +18℃~+30℃ | ||||||
Humidity range | 10%~85%RH | |||||||
Atmospheric pressure | 700hPa~1060hPa | |||||||
Transport and storage condition | Temperature range | -10℃~+55℃ | ||||||
Humidity range | ≤95% | |||||||
Atmospheric pressure | 500hPa~1060hPa |
![]() |