IMEC5 IMEC8 IMEC10 IMEC12 Patient Monitor Li-Ion Battery LI131001A Mindray Ipm5 Ipm8 Ipm10 Ipm12

Categories Patient Monitor Accessories
Brand Name: Mindray
Model Number: LI131001A
MOQ: 1
Payment Terms: T/T, Western Union,PayPal
Delivery Time: 3-5 working days
Product name: Mindray
Type: Li-ion battery
Application: medical equipment,ICU,hospital device,defibrillator
Warranty: 90days
PN: LI131001A
Product situation: In Good Order
Mode of transport: Expressage
Product Type: rechargeable lithium battery
Packaging Unit: 1 per case
Voltage: 12 VDC (±10%)
Current: 3.5 A
Charge time when the monitor is off: Less than 3 hours to 90%, and less than 4 hours to 100%
Charge time when the monitor is on: Less than 8 hours to 90%, and less than 12 hours to 100%
Shutdown delay: at least 20 min (after a low battery alarm first occurs)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

IMEC5 IMEC8 IMEC10 IMEC12 Patient Monitor Li-Ion Battery LI131001A Mindray Ipm5 Ipm8 Ipm10 Ipm12


Mindray ipm5 ipm8 ipm10 ipm12 IMEC5 IMEC8 IMEC10 IMEC12 patient monitor Li-ion battery LI131001A compatible new


► Brief Introduction

When the patient monitor working, you can run the patient monitor on a rechargeable lithium battery. When a battery is installed, the equipment will automatically run power from the battery in the case that external power fails.

The battery is located at the base of patient monitor. The battery power is input into power module through battery connector board, and then power module processes and forwards the power into each components of the patient monitor.

This rechargeable Lithium-ion battery power during intra-hospital patient transfer or whenever the power supply is interrupted.

The battery is charged automatically when the monitor is connected to AC/DC power, no matter the monitor is powered on or not. Whenever the AC/DC power is interrupted during patient monitoring, the patient monitor automatically runs power from the internal battery. iPM 12/iPM 7 patient monitor is available for up to two batteries. iPM 10/iPM 6 or iPM 8/iPM 5 patient monitor is available for only one battery.


► Battery Check

  1. If the patient monitor is installed with a battery, remove the battery first.
  2. Verify that the patient monitor works correctly when running powered form an AC source.
  3. Insert the battery per the procedures provided in the Operator’s Manual.
  4. Remove the AC power cord and verify that the patient monitor still works correctly.

On-screen battery symbols indicate the battery status as follows:

1.

Indicates that the battery works correctly. The solid portion represents the current charge level of the battery in proportion to its maximum charge level.

2.

Indicates that the battery has low charge level and needs to be charged. In this case, the patient monitor provides an alarm message.

3.

Indicates that the battery is almost depleted and needs to be charged immediately. Otherwise, the patient monitor shuts down automatically.

4.

Indicates that no battery is installed.


The capacity of the internal battery is limited. If the battery charge is too low, a technical alarm will be triggered and the message [Low Battery] or [Battery Depleted] displayed. At this moment, apply AC/DC power to the patient monitor. Otherwise, the patient monitor will power off automatically before the battery is completely depleted.


Specifications

Charge timeLess than 3 hours to 90%, and less than 4 hours to 100% when the monitor is off.
Less than 8 hours to 90%, and less than 12 hours to 100% when the monitor is on.
Shutdown delayat least 20 min (after a low battery alarm first occurs)

Thank you for your time and interest in Mindray ipm5 ipm8 ipm10 ipm12 IMEC5 IMEC8 IMEC10 IMEC12 patient monitor Li-ion battery LI131001A compatible new, "Quality assurance" is our eternal pursuit and promise. Don't be hesitant to contact us! Welcome to place your orders.