Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home > Air Conditioners >

2KW ASTM E 846 Flammability Testing Equipment For Flooring Radiant Heat Flux

Categories Flammability Testing Equipment
Brand Name: YUYANG
Model Number: YYT001
Certification: CE
Place of Origin: China
MOQ: 1PCS
Price: $30000
Payment Terms: T/T
Delivery Time: 7-30 Days
Packaging Details: Wooden Box
Heat flux measurement range: (0-15) Kw / m2
Heat flux meter accuracy: ± 0.2Kw / m2
Flame height: 60 ~ 120mm adjustable
Exhaust speed: (2.5 ± 0.2) m / s
Ignition system: high-voltage electronic ignition
Combustion gas flow rate: (0.026 ± 0.002) L / S
Total power: 2KW
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

2KW ASTM E 846 Flammability Testing Equipment For Flooring Radiant Heat Flux


ISO 9239-1 ASTM E 846 Flooring Radiant Heat Flux Test Apparatus Tester Machine


Introduction:

ISO 9239 Radiant Flooring Panel test is the cornerstone of the flooring materials reaction to fire tests in the Euroclass system. The apparatus measures the spread of flame of the sample, under thermal exposure, using a radiant heat ignition source. The thermal exposure is that of a fire growing in the room of origin that through a door opening, radiates onto the floorings in an adjacent room or corridor.

This Flooring radiant panel test apparatus can also be used for tests to standards ASTM E648 and DIN 4102; Part 14.

Standard:

GB / T11785 "flooring combustion performance measurement - a radiant heat source”
ISO9239-1:2002 “flooring combustion performance Part 1-the combustion performance is determined with radiant heat resource”
ASTM E648:Standard Test Method for Critical Radiant Flux of Floor-covering Systems Using a Radiant Heat
ASTM E970:Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
NFPA 253:Standard Test Method for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source


Feature

  • The resulting test chamber is insulated with calcium silicate insulation board and is provided with a temperature resistant observation window.

  • The stainless steel sample support assembly is mounted on a sliding platform to allow safe and easy loading of the test sample.

  • The radiant heat is applied by means of a gas-fuelled panel, inclined at 30º, and directed at a horizontally mounted floor covering system specimen.

  • The radiant panel generates a radiant energy flux distribution ranging from a nominal maximum of 10.9 kW/m2 to a minimum of 1.1 kW/m2.

  • Dummy calibration specimen with holder, calibrated heat flux meter and mounting.

  • The distance burned until flame-out is reached and converted, by calibration, into an equivalent critical radiant flux, in kW/m2.

  • Heat Flux Meter of ISO9239 flooring radiant panel tester: Range : 0 ~ 50 kw/m2; Surface emissivity :ε=0.95± 0.05

  • A smoke measuring system, according to DIN 50055, is mounted on a separate frame at the exhaust stack.

  • Control Rack for convenience in use, allowing observation of iso 9239 flooring panetl test apparatus and controls during equipment set-up and calibration.

  • Automatic ignition of the radiant panel and safety cut-out.

  • Automatic moving T type ignition burner

  • Stainless steel hood with smoke measurement ports.


Installation requirements of EN ISO 9239-1 Flooring Radiant Panel Test Apparatus

1Electrical230 volts Nominal 10 Amps
2Ambient TemperatureOperating 10°C to 35°C
3Gas SuppliesPropane and air compressor
Quality 2KW ASTM E 846 Flammability Testing Equipment For Flooring Radiant Heat Flux for sale
Send your message to this supplier
 
*From:
*To: DONGGUAN YUYANG INSTRUMENT CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0