Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home > Eyeglasses Lenses >

6mm Foldable Hydrophilic Acrylic Intraocular Lens OEM ISO9001

Categories Foldable Intraocular Lens
Brand Name: Universe IOL
Model Number: PCF60
Certification: ISO13485,ISO9001
Place of Origin: China
MOQ: 1000 pcs
Price: negotiation
Payment Terms: T/T
Supply Ability: 10000 pcs per month
Delivery Time: 7 working days
Packaging Details: 170 pcs per box(Size:47x48x39cm)
Material: Hydrophilic Acrylic
Water Contents: 26%
Model: PCF60
Body diameter: 6.0mm
Overall diameter: 12.5mm
Power: 0-30D
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

6mm Foldable Hydrophilic Acrylic Intraocular Lens OEM ISO9001

Hydrophilic Acrylic Foldable Intraocular Lens with Water Contents 26%


Hydrophilic Acrylic Foldable Intraocular Lens with Water Contents are copolymers of HEMA and PMMA, with water contents of 26%, and are much more resistant to deformation and opacification.


Foldable IOLs have helped alter the face of cataract surgery by improving healing time, limiting complications and making phacoemulsification the standard procedure over extracapsular surgery, all in the span of 2 decades.

At first, the new lenses and procedures were not widely accepted at their advent in the mid-1980s, physicians said. PMMA IOLs were the standard IOLs used at that time, and they were typically inserted through 5-mm to 7-mm incisions after extracapsular surgery. More than 20 years later, most surgeons now implant foldable acrylic or silicone IOLs after phaco, and PMMA lenses are used only in special cases.


Material:Hydrophilic AcrylicWater Contents:26%
Model:PCF60Body Diameter:6.0mm
Overall Diameter:12.5mmPower:0-30D

Indications:

  1. Cataract on both eyes.
  2. Cataract of single eye in patients, who is unwilling or unfitful to wear corneal contact lens
  3. Aphakic eye caused by various reasons


Instruction for Use

  1. Examine the type, diopter power, size, the period of validity indicated on the outside package label. DO NOT USE if the expiration date has passed.
  2. Take out the tyvek pounch and check that there is no damage on it, verify that lens power, size, type on the vial are same with the data on the outside label.
  3. Open the pounch under the aseptic place, open the lens case after final confirmation of lens model and diopter power, take out IOL very carefully and implant IOL into eyes.
  4. Rinse the IOL with infusion solution or the equivalent.

Precautions

  1. Do not use the One-piece Posterior Chamber Foldable Intraocular Lens if it is after expiration date.
  2. Do not try to re-sterilize the One-piece Posterior Chamber Foldable Intraocular Lens.
  3. The surgeon must be the person who had observed and assisted IOL implantation surgery many times, must be also the person , who has been ophthalmologist with rich experience and independently completed the IOL omplantation successfully for at least one time.
Quality 6mm Foldable Hydrophilic Acrylic Intraocular Lens OEM ISO9001 for sale
Send your message to this supplier
 
*From:
*To: Henan Universe Intraocular Lens Research and Manufacture Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0