Sign In | Join Free | My frbiz.com |
|
Categories | Split Case Fire Pump |
---|---|
Brand Name: | CNP NM FIRE |
Model Number: | SCF125-100-330x2(UL) |
Certification: | UL |
Place of Origin: | China |
MOQ: | 1set |
Price: | Negotiation |
Payment Terms: | L/C, T/T |
Delivery Time: | 60 Days |
Packaging Details: | Export Packing |
Engine: | NM&UL |
Capacity: | 750GPM |
Head: | 296PSI |
RPM: | 2950 |
Casing: | Ductile Cast iron |
Impeller: | SS304 |
Pressure: | High pressure ,Low pressure |
Power: | Electric , Diesel |
Company Info. |
Wuhan Spico Machinery & Electronics Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
The following is a split case diesel pump set suitable for 750G PM 196 PSI, and the fuel tank capacity meets the requirements of NFPA20.
Diesel Engine Pump Set ( Heat Exchanger) | Pump: NM FIRE Model: SCF125-100-330x2(UL) Q= 750usgpm H=296psi n=2950 rpm Material: Casing---Ductile Cast iron Impeller---SS304 Shaft--- AISI 4340 Shaft sleeve---SS304 Seal------ Gland packing Wear ring----Bronze Bearing---SKF | This Diesel Engine Group include: 1. the pump(air relieve valve , inlet & outlet gauges); 2. Diesel Engine; 3. Commonbase; 4. Silencer; 5. Flexible exhaust connector; 6. Coupling; 7. Cooling System; 8. Control System; 9. Fuel tank; 10. Flowmeter; 11. Main relief valve; 12. Waste cone; 13. Test Fee. Batteries Exclude due to china customs restrictions. | ||||||||||||||||||||||||||||||||||||||||||
Engine: NM FIRE(UL) Model: NM6-110D 200kw at 2900rpm | ||||||||||||||||||||||||||||||||||||||||||||
Fuel tank:NM FIRE(NFPA 20 Compliant-non-approved) Model: NMTY-YX-1200L-00-01 Single wall | ||||||||||||||||||||||||||||||||||||||||||||
Controller : Tornatech(UL/FM) Model: GPD-24-120/220 | ||||||||||||||||||||||||||||||||||||||||||||
Flowmeter (Grooved pipe)(FM) Model: 5"-750-G | ||||||||||||||||||||||||||||||||||||||||||||
Main relief valve: Cla-Val (UL/FM) Model: 2050B-4KG1 4" 100-300psi | ||||||||||||||||||||||||||||||||||||||||||||
Waste cone: NM FIRE Model: 4"-6" |
NMFIRE Factory-Built Containerized Pump Rooms combine a complete
fire pump system, suction and discharge piping, electrical and
exhaust components, all housed in a specially designed container.
Pump Rooms are designed, built, and tested in a controlled
ISO9001:2015 factory environment and shipped to the job site ready
for immediate installation. The system piping and electrical
connections are ready for immediate hook-up which significantly
reduces on-site labor and shortens construction project timelines.
Value Added Systems
• 3D design built in an NFAP20 engineering environment with the
highest quality
Standards
• All main components are UL/FM Listed and Approved products
• Complete system is pressure tested before shipment to eliminate
on-site leaks
• All interior piping and electrical connections are complete
• Factory assembly and testing eliminates the need for on-site
assembly
• Enclosure floor is coated
• Superstructure design supports the system piping, exhaust piping,
and electrical components from the roof, allowing for more open
floor space
• Wall insulation reduces environmental noise
• Includes all auxiliary systems prescribed by NFPA20 including:
• Heating • Lighting • Sprinklers • Ventilation • Drainage
All petroleum, petrochemical, chemical, military and naval
institutes, oil fields of Petro China, Sinopec, CNOOC, pipelines
Bureaus, oil repositories, oil terminals, construction companies,
oil refineries, offshore platforms, etc.
Fire-fighting Engineering Companies, airports, highway tunnels,
hotels, hospitals, supermarkets, office buildings, national grain
storages, thermal power plants, shipyards, paper mills, subway
stations, railway stations, etc.
Steel plants, residential regions, industrial and mining
enterprises, house building materials supermarkets, etc.
①The late-mover advantage of products, we R&D better fire products than other Suppliers;②Have the most complete and all series of fire pump models;③ Have listed diesel engines with the self-owned brand--- NM FIRE;④ Understand the technology of fire- fighting products and fire- fighting system better than other competitors and have better services;⑤ Shorter delivery time.
Q1. Do you have the UL-LISTED Fire Pump Sets?
Yes, We have the UL/FM and NFPA standard Fire Pump Sets.
Q2. I need your motor drive End-suction/Split-casing fire pump,
what information should I send to you?
Sir/Madam, you can provide the Capacity, Heed, Voltage, and
Frequency, we will make the quotation for you, If you need a Jockey
Pump or other accessories, please tell us together.
Q3. If I need your Diesel Engine Drive End-suction/Split-casing
fire pump, what information should I send to you?
You can send the Capacity Heed, Temperature, and Altitude
(temperature and altitude will affect the performance of diesel
engines). If you need a Jockey Pump or other accessories, please
tell us the Voltage and Frequency or accessories together.
Q4. I need the UL/FM Vertical Turbine Fire Pump Set, please sent me
the price.
For the motor Diver Vertical Turbine Fire Pump Set: you should give
us the Capacity, Heed, Voltage Frequency, and the tank deep.For the
Diesel Engine Drive Vertical Turbine Fire Pump Set: you should give
us the Capacity, Heed, and the tank deep. If you need a Jockey Pump
or other accessories, please tell us together.
1. Reply within 24 hours.
2. High-quality products and the most reasonable price
3. Data and chemical technology support.
![]() |