Real High-Resolution Retinal Image Automated Fundus Camera
Automated Fundus Camera RetiCam 3100 is base on traditional fundus camera, through the
binocular stereo vision and XYZ three-dimensional automatic
positioning by image feature recognition, and through the split
line to achieve automatic focusing, determined by CCD imaging
feedback automatic metering and exposure intensity to realize
automatic exposure, and then control the focus motor according to
the image resolution, to present real high-resolution retinal imag.
In default setting, this product works for a pupil with a standard
diameter of 4.0 mm or larger. In a small pupil mode, it can take
fundus images for pupils with a diameter of 3.3 mm or larger.
Acquisition Modes | Automated Fundus Camera/mydriatic Anterior photography
/Red-free(optional)(FFA)/(FAF) |
Field View | 50° |
Working Distance | 35mm |
Minimum Pupil | ≥3.3mm |
Focus Modes | Manual/Auto |
Alignment Modes | Double dots auxiliary |
Exposure | Manual /Auto |
Photography | SLR Camera |
Image definition | 24 Megapixel |
Compensation | ±25D |
Fixation | External /Internal (any position available) |
DICOM 3.0 | Support |
Automated Fundus Camera in the world |
Brand | TOPCON(NW-400) | DRS | NEWVISON(RETICAM3100) |
operation | automatic(one key taking picutre)/manual | automatic(one key taking picutre)/manual | automatic(one key taking picutre)/manual |
Acquisition modes | fundus/anterior/? | fundus/anterior/red-free filter | fundus/anterior/red-free filter/FFA(optional)/FAF(optional) |
Filed of view | 45 degree | 40-45degree | 45-50degee |
Mosic degee | | 80 degree | 135degree |
Minimum pipil size | 3.3mm | 3.5mm | 3.3mm |
Resolution | above 18megapiexl | sensor size:5 megapixel sensor resoultion: 48 pixel/degree | above18 megapixel (24 megapixel optional ) |
Fixation | 9 internal + 1 outside fixaiton | 7 internal fixation | countless fixaiton, any position is available during range + 1
outside fixation |
Technology of focus | | | Dual camrea technology |
exposure ligh | standard | standard | new technology, more soft, one patient same eye can take picuture
consecutive with almost same performace |



Company Introduction

Focusing on the two major public health problems of adolescent
myopia and elderly ophthalmology, our company researches new
diagnostic and treatment equipment for ophthalmology, develops
low-cost applicable technology products, realizes
industrialization, reduces the cost of social medical and health
system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development
concept.We have a strong technical force, has been awarded 11 patents, and
obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect
after-sales service system to provide medical equipment with the
highest cost performance and meticulous service.