KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen

Categories Water Quality Sensor
Brand Name: kacise
Model Number: KFDO310
Certification: CE
Place of Origin: CHINA
MOQ: 0-100
Price: $0-$2000
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100
Delivery Time: 3-10days
Packaging Details: Common package or custom package
Measuring principle: fluorescence
Range: 0ー20 mg/L (0ー200% saturation, 25 °C)
Resolution: 0.01 mg/l, 0.1 °C
Precision: ± 2% f.s. , ± 0.5 °C
Temperature compensation: Automatic temperature compensation (PT1000)
Output mode: RS-485 bus, Modbus-RTU protocol
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen

1.Principle


KFDO310 integrated on-line fluorescence dissolved oxygen sensor is designed and made based on the quenching principle of excited fluorescence of specific substances in physics. The blue light from the light-emitting diode illuminates the fluorescent material on the inner surface of the fluorescent cap. The fluorescent material on the inner surface is excited and emits red light. By detecting the phase difference between the red light and the blue light, and comparing it with the internal calibration value, the concentration of oxygen molecule can be calculated, and the final value can be output by temperature automatic compensation.


2.Feature


  • No electrolytes, no polarization
  • No need to consume oxygen, not affected by the flow rate
  • Built-in temperature sensor, automatic temperature compensation
  • Free from chemicals like sulfides
  • Small drift, fast response, more accurate measurement
  • Maintenance-free, long service life, lower use cost
  • Fluorescent caps are easy to replace
  • RS-485 interface, Modbus-RTU protocol

3.Technical Specifications


Model numberKFDO310
Measuring principlefluorescence
Range0ー20 mg/L (0ー200% saturation, 25 °C)
Resolution0.01 mg/l, 0.1 °C
Precision± 2% f.s. , ± 0.5 °C
Temperature compensationAutomatic temperature compensation (PT1000)
Output modeRS-485 bus, Modbus-RTU protocol
Working conditions0ー45 °C, < 0.2 mpa
Storage temperature- 5 ~ 65 °C
Installation modeImmersion mounting
Cable length5 meters, other length can be customized
Power consumption< 0.05 W
Power supply12 ~ 24 VDC ± 10%
Protection levelIP68
CalibrationTwo-point calibration
Fluorescent cap lifeGuaranteed Use for one year (under normal use)
Material for sensor housingPom and 316L stainless steel

4.Dimensional Drawing



5.Installation and Electrical Connection

Installs

The temperature sensing part should be immersed below the liquid surface to avoid collision with the film head surface. The head part of the membrane should be free from sediment.


Pulsed Polarographic Dissolved Oxygen Sensors



Pulsing polarographic dissolved oxygen sensors remove the need to stir a sample for accuracy when measuring dissolved oxygen. A rapid-pulse DO sensor is similar to a steady-state polarographic DO sensor as both utilize a gold cathode and silver anode. Both steady-state and rapid-pulse sensors also measure dissolved oxygen by producing a constant voltage to polarize the electrodes 7. However, these pulsing polarographic DO sensors turn on and off approximately every four seconds, allowing the dissolved oxygen to replenish at the membrane and cathode surface 7. This replenishing creates a flow dependence of almost zero 7. In order to consistently polarize and de-polarize the electrodes for these short time periods, a pulsing polarographic DO sensor includes a third, silver reference electrode, separate from the silver anode 7. The electrochemical reaction (silver oxidation and oxygen reduction) remains the same.

As rapid-pulse polarographic sensors reduce flow dependence when taking DO measurements, the water sample does not need to be stirred when using this sensor.

Quality KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen for sale