Sign In | Join Free | My frbiz.com |
|
Categories | High Flow Filter Cartridge |
---|---|
Brand Name: | PULLNER |
Model Number: | PHFM |
Certification: | FDA |
Place of Origin: | Shanghai China |
MOQ: | 1 |
Price: | Negotiable |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal |
Supply Ability: | 800pcs per week |
Delivery Time: | 3-7days |
Packaging Details: | Carton box after poly bag. 4pcs per carton |
PHFM: | High Flow Pleated Filter |
Material: | PP |
Filter area: | 6.6㎡ |
Flow rate: | 110m³/hr |
Filtration Efficiency: | Beta 5000 |
OD: | 160mm |
Filtration micron: | 1um, 2um, 5um, 10um, 15um, 20um, 30um, 50um, 70um, 100um |
Length: | 20"(508mm), 40"(1016mm), 60"(1524mm) |
Maximum Operating Differential Pressure: | 3.5bar@21℃ |
Maximum Operating Temperature: | 82℃ |
Company Info. |
Shanghai Pullner Filtration Technology Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
Power Station Condensate Water Beta5000 10um 60" High Flow Pleated Filter 99.8% Efficiency
General information
PHFM series high flow filter cartridge adopts 160mm large diameter
structure with single open end. Use advanced pleat technology,
provide bigger filtration area, high flow rate and long service
life. All connection use thermal welding, no any adhesive, wide
Chemical compatibility.
Performance comparison
Comparison chart of specific filter element number and
corresponding filter footprint
Material Construction
Filter Media | PP: Deep Pleated PP/Melt PP | FO: Organic Fiber | GF: Resin Synthetic Glass Fiber |
Support/Drainage | PP | Organic Fiber | Polyester |
End Cap Material | Fiberglass Reinforced Polypropylene | Fiberglass Reinforced Polypropylene | Fiberglass Reinforced Polypropylene |
Filter Performance
Micron | 1um, 3um, 5um, 10um, 15um, 20um, 50um, 70um, 100um |
Max. operating temperature | 82℃ |
Max. operating differential pressure | 3.44bar@82℃ |
Suggestion pressure for filter replacement | 2.5Bar@20℃ |
Flow Rate and Filtration Area
Size (Diameter*Length) | Design Flow (m3/hr) | Maximum Flow (m3/hr) | Filtration Area (㎡) |
6"*20" | 15 | 40 | 2.6 |
6"*40" | 30 | 80 | 5.2 |
6"*60" | 45 | 120 | 7.8 |
![]() |