Sign In | Join Free | My frbiz.com |
|
Categories | Electrical Test Instrument |
---|---|
Brand Name: | AI |
Model Number: | CBA-II |
Certification: | ISO9001 |
Place of Origin: | China |
MOQ: | 1 set Circuit Breaker Test Apparatus |
Price: | Negotiable |
Payment Terms: | Western Union, T/T, L/C |
Supply Ability: | 100 sets/motnh |
Delivery Time: | 15 days |
Packaging Details: | Circuit Breaker Test Apparatus packed in veneer case |
Functions: | For all kinds of Circuit Breaker testing, High Voltage Vacuum Type Circuit Breaker Test Apparatus |
Test standard: | IEC62271 |
Time test: | 0 to 6 seconds |
Distance test: | 0-250mm |
Power supply: | 220V, 50Hz |
Size: | 400mm*350mm*200mm |
Weight: | 7kg |
Warranty: | 1 year |
Company Info. |
Advanced Instruments Co.,Limited |
Verified Supplier |
View Contact Details |
Product List |
Introduction:
The Circuit Breaker Test Apparatus is my company designed to meet the need of testing high-voltage circuit breakers . It takes the ARM7 unit for core to sample, process and then output.
It has many advantages such as intelligence, multi-function, accurate data, strong anti-jamming, easy operation, small size, beautiful appearance, etc. It can test the circuit breakers as follows: indoors or outdoors circuit breakers with less oil or more oil, vacuum circuit breakers, SF6 circuit breakers and so on.
Main Functions of CBA-II Circuit Breaker Test Apparatus:
★ Test standard: IEC62271;
★ Closing and opening time measurement of 12 channels;
★ Max difference of closing or opening time measurement of three phases;
★ C-O and O-C time measurement;
★ Rated operation sequence test;
★ Bounce time and frequency measurement of breaker closing;
★ Circuit breaker closing and opening speed measurement;
★ Travel-time, coil current-time curve of circuit breaker operation measurement;
★ Travel and clearance of circuit breaker measurement;
★ Variable DC circuit breaker operation power supply;
★ Closing arc resistance value and connected time measurement;
★ Closing time and opening time of graphite circuit breaker measurement;
★ Print test results by internal micro printers.
Specifications of CBA-II Circuit Breaker Test Apparatus:
1 | Time | Simultaneity measure Contacts | ≤12 |
Range | 0—6s | ||
Resolution ratio | 0.01ms | ||
2 | Travel | Range | < 250mm |
Resolution ratio | 0.01mm | ||
3 | Error | Time measure error | ±0.1% |
Travel measure error | ±1mm | ||
4 | Speed measure range | 0—20m/s | |
5 | Internal Power | Output Voltage | 20V—265V error:1% |
6 | Operating conditions | Operating voltage | AC220V±10 % |
Frequency | 50Hz | ||
Power dissipation | ≤60w | ||
Ambient temperature | 0~40°C | ||
Ambient humidity | ≤90%RH | ||
7 | Dimension | 400*350*200 mm3 | |
8 | Weight | 7KG |
Real Photo of CBA-II High Voltage Circuit Breaker Test Apparatus
![]() |