Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home > Heat Exchanger >

Aluminum air to air heat exchanger for compressed air aftercooler industry application

Categories Air to Air Heat Exchanger
Brand Name: ADV
Model Number: ADV -OC-03
Certification: ISO9001
Place of Origin: Changzhou China
MOQ: 1 Unit
Supply Ability: 1~50 + Units + 25 Working Days
Delivery Time: 7~15 Working Days
Packaging Details: Wooden Packing
Product: Industrial air to air heat exchanger for compressed air after-cooler
Material: Aluminum AL3003
Technic: Vacuum Brazing
Max Size: CUSTOM AVAILAVLE
Max Pressure: CUSTOM AVAILAVLE
Test: Leak Test & Performance Test & Pressure Pulse Test & Vibration Test
Usage: Industrial, Construction Machinery, Hydraulic System, Compressor Machinery, Automatic , Agriculture Machinery, Railway, Wind Powder Generation
Warranty: 12 month
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Aluminum air to air heat exchanger for compressed air aftercooler industry application


Aluminum air to air heat exchanger for compressed air aftercooler industry application

Description:

1.Aluminum air to air heat exchanger, compact size and efficient performance
2.Aluminum plate and bar type air/oil cooler
3.working pressure: 2-40 bar
4.working temp : -10-220 Deg C
5.ambient temp:0-50 Deg C


Material Description & Working Situation


Main Cooler Body​

Aluminum

Housing

Powder painted steel

Fan Guard

Galvanized plate

Fan Blade

Polypropylene

Maximum Working Pressure

250 PSI

Maximum Working Temperature

110℃


Technic Specification : (took from 220 KW)


SPECIFICATIONAir to air heat exchanger
Item numberADV-CMP009
Technical data(Standard values)
Compressor driving powerKW/HP160/220
Oil cooling powerKW122
Air cooling powerKW37
Oil flowLit/min120
Air flowKg/hr2100
Cooling Air flowKg/hr18,000
Approximate cooler dimensions
Amm/inch840
Bmm/inch382
A+Bmm/inch1222
Cmm/inch1120
Dmm/inch1270
Emm/inch95
Max working pressurebar(g)/psig15/218
Test Pressurebar(g)/psig20/290
Air cooler connecting slot[G"]inch2(M+P)
Oil cooler connecting slot[G"]inch1-1/2(N+O)
Cooler weight approx.Kg/lb108.5
Fan speedrpm
Fan diametermm/inch
Oil inlet temperatureMax 120
Air inlet temperatureMax 120

LAB & Test


1.Leak Test of Every Unit


Aluminum Bar and Plate Heat Exchanger oil cooler air cooler water radiator for railway vehicles cooling system


2.Performance Test ( Available)

Performance Test:Compressed Air SystemWater Glycol SystemWater Glycol System
Flow:0-48Nm3/min400L/min600L/min
Temp:≤200°C≤100°C≤110°C
Max. heating power:110KW180KW240KW

Aluminum Bar and Plate Heat Exchanger oil cooler air cooler water radiator for railway vehicles cooling system


3. Pulse Test ( Available)


Aluminum Bar and Plate Heat Exchanger oil cooler air cooler water radiator for railway vehicles cooling system


4. Viberation Test (Available)


Aluminum Bar and Plate Heat Exchanger oil cooler air cooler water radiator for railway vehicles cooling system


5. Salty Spay Test

we can offer C5 standard preservative treatment preservative treatment, please contact us fr more information


Aluminum Bar and Plate Heat Exchanger oil cooler air cooler water radiator for railway vehicles cooling system


ADV Service Advantage
  • 3D model drawing available
  • Prototype testing and confirmation
  • Steel frame support, Front to Back type design and manufacturing
  • Easy mounting and maintain, Good anti-vibration
  • Stable Performance & Low Pressure Drop
  • Compact Design & Light Weight
  • Motor & Fan is Optional
  • 12 Month Global Warranty

Customization Service

Aluminum Bar and Plate Heat Exchanger oil cooler air cooler water radiator for railway vehicles cooling system


You just need to tell us your specific requirements and environmental parameters for your Aluminum air to air heat exchanger for compressed air aftercooler, so that we can make professional quotations accordingly.

Please advise:


Oil parameterFluid
Flow
Inlet temperature (℃)
Cooling power (kw)
Max. allowable pressure drop
Max. work pressure (MPa)
Air parameterFlow
Inlet temperature (℃)
Cooling power (kw)
Max. allowable pressure drop
Max. work pressure (MPa)
Cool air parameterFlow & Pressure curve
Inlet temperature (℃)
Air trace
MountingMax overall dimension
Location of connections
Requirement of structure
Working condition

Be free to contact us if you need any further information, thank you!

Product Tags:

air heat exchanger

  

inter cooler

  
Quality Aluminum air to air heat exchanger for compressed air aftercooler industry application for sale
Send your message to this supplier
 
*From:
*To: Changzhou ADV Heat Exchanger Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0