1 Station Electrical Appliance Tester 220V Label Marking Abrasion IEC60730-1
Production introduction:
This testing apparatus is design and manufactured according to IEC60730-1 standard figure 8 and annex A requirements, used for testing the controller marking durability performance.
The apparatus comply with the dimensions requirements of IEC 60730-1 Figure 8. Test times can be set from 1 to 999999 (default as 12 times), test rate 48 rpm. It is a easy operated professional equipment.
Main technical parameters:
Equipment | Markings durability tester |
Test station | 1 station |
Test stroke | 20mm |
Test rate | 48rpm |
Test times | 1~999999, default as 12times |
Sliding weight | 500g. Strip weight 250g, with weight 750g |
Brass washer | Φ60*2.5mm |
Friction wheel | Φ65*7.5mm |
Power supply | 220VAC 50Hz |
Standard | IEC 60730-1 Figure 8, Annex A |
Test Operation
Presetting and parameters of instrument
Counter/Timer: Press down [MD] for three seconds to enter setting state→ the display mode is[IN]→press ▲or ▼to select [U]mode →repress [MD]→the display mode is [CPS]→press ▲ or ▼to select [30]→this analogy→ finally press down [MD]for three seconds to complete the setting procedure. Press<left arrow to select the figures,and then press ▲upward or ▼downward to select the required number,and then press[MD] to confirm it. For the setting method in detail, please refer to the detailed instructions to the setting of various parameters. | ||||
Counter | ||||
Input mode IN | U | Input logic SG | PNP | |
Counting speed CPS | 30 | Resetting time RST | 20 | |
Output mode OUT | F | Counting/Timer C-T | COUN | |
Output time OUT.T | HOLD |
![]() |