IEC 60068-2-75 Test Eha 2J 5J 10J 20J Striking Element Electromagnet Release Impact Test Apparatus

Categories Electrical Appliance Testing Equipment
Brand Name: Sinuo
Model Number: SN2206
Certification: Calibration Certificate (Cost Additional)
Place of Origin: China
MOQ: 1
Price: Customized
Payment Terms: L/C, , T/T, Western Union, MoneyGram
Supply Ability: 20 sets per month
Delivery Time: 30 Days
Packaging Details: Plywood
Energy: 2, 5, 10, 20, 50J optional
Striking Elements: 500g,1.7kg,5 kg, 5 kg,10 kg optional
Impact Point: Adjustable
Release Method: Electromagnet
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

IEC 60068-2-75 Test Eha 2J 5J 10J 20J Striking Element Electromagnet Release Impact Test Apparatus


IEC 60068-2-75 Test Eha 2J 5J 10J 20J Striking Element Electromagnet Release Impact Test Apparatus


Standards & Clauses:


IEC60068-2-75:2014 “Environment testing for electric and electronic products Part2: Test methods -Test Eh: Hammer tests IDT”

IEC60598-1:2017 “Luminaries-Part1: General requirements and tests”

IEC62262:2002 “Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) ”


Samples and Restrictions:


Enclosures of household and similar electronic and electrical products, luminaires


Application:


It is used for the impact resistance test of the enclosures of household and similar electronic and electrical products and their accessories, luminaires, etc., to assess the safety performance and strength level of the products.


Test Principle:


Test Eha:Pendulum Hammer, the striking element is free released at a certain height through a 1 m pendulum tube,impact the specimen at the lowest point in the vertical direction, after the conversion of gravitational potential energy to kinetic energy, to achieve the purpose of impact test on the sample.


Structure:


Cantilever frame,electric lift, the striking element is released by the electromagnet, fix the striking element to the height of fall through the conduit, the impact point is adjusted by XY axis movement.

Technical Parameters:


Energy / J2, 5, 10, 20, 50J are optional

Striking Elements

(Equivalent Mass)

500g,1.7kg,5 kg,5 kg,10 kg ,please refer to the following table 1
ConduitEach striking element is equipped with a dedicated conduit
Impact PointThe device has X and Y axis guides to move the release device over the entire bottom area
Height of Impact Point0-1000mm,electric adjustable
Height of FallPlease refer to table 2, fixed by the conduit
Release MethodElectromagnet release
Bottom PlateNylon base plate thickness 8mm, hardnessHRR85-100,1000m×1000m

Table 1 Striking element characteristics

Energy / J

≤1

±10%

2

±5%

5

±5%

10

±5%

20

±5%

50

±5%

Equivalent Mass ±2%kg0.25(0.2)0.51.75510
MaterialNylonSteel
R/mm102525505050
D/mm18.5(20)356080100125
f/mm6.2(10)710202025
r/mm--6-1017
l/mmAdjusted according to the Equivalent Mass, see Appendix A

Table 2 Height of Fall

Energy /J0.140.2(0.3)0.35(0.4)0.50.7125102050
Equivalent Mass /kg0.25(0.2)0.25(0.2)0.25(0.2)(0.2)0.250.250.250.51.75510
Height of Fall ±1%mm56(100)80(150)140(200)(250)200280400400300200400500
Note 1, see note 3.2.2; Note 2, the energy unit of this part of the joule (J) is derived from the standard gravity acceleration (g), the whole value of g round: 10m / s2.

Table 3 Relationship of IK code and corresponding energy

IK CodeIK00IK01IK02IK03IK04IK05IK06IK07IK08IK09IK10
Energy / Ja0.140.20.350.50.71251020

Note 1. If higher impact energy is required, the recommended value is 50J.

Note 2: Some other standards use a single digit to indicate the specified impact energy. To avoid mixing with it, the feature number is represented by two digits.

a Unprotected according to this standard

Quality IEC 60068-2-75 Test Eha 2J 5J 10J 20J Striking Element Electromagnet Release Impact Test Apparatus for sale