Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home >

ADK11-25A / 25G / 25N CKD Type 2 Port Pilot Kick Solenoid Diaphragm Valve G1'' Inch NC Type

Categories Brass Solenoid Valve
Brand Name: Brando
Model Number: ADK11-25
Certification: CE
Place of Origin: China
MOQ: 1 set
Price: negotiation
Payment Terms: L/C, T/T, Western Union,Paypal, MoneyGram
Supply Ability: 100000 sets per month
Delivery Time: 4-8 days
Packaging Details: Inner Box, Carton, Pallet
Model: ADK11-25 CKD Type
Port size: G1'' Inch
Name: 2 Port Pilot Kick Solenoid Diaphragm Valve
Body and seal material: Brass and EPDM, or Customized
Structure: Diaphragm
Action type: Internal pilot actuated
Function: Normally closed (NC)
Connection: Threaded
Voltage: DC12V, DC24V, AC110V, AC220V
Fluid temperature: -10 to 60℃
Max. working pressure: 2 MPa
Working fluid: Air/Low vacuum, water/paraffin/oil
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

ADK11-25A / 25G / 25N CKD Type 2 Port Pilot Kick Solenoid Diaphragm Valve G1'' Inch NC Type

ADK11-25A / 25G / 25N CKD Type Pilot Kick Solenoid Diaphragm Valve G1'' Inch NC Type


This 2 Port Pilot Kick Solenoid Valve Diaphragm Structure is similar with CKD Type ADK11-25A / 25G / 25N solenoid valve. Its structure is mainly composed of pilot valve and main valve. The main valve adopts rubber sealing structure. When in normal position, the movable iron core seals the pilot valve port, the pressure is balanced in the valve chamber, and the main valve port is closed. When the coil is energized, electromagnetic force will be generated to attract the moving iron core, and the medium in the main valve cavity leakage of the valve orifice, resulting in pressure difference, diaphragm or valve cup is quickly held up, the main valve orifice opened, the valve was a path. When the coil is cut off, the magnetic field disappears, the active iron core is reset, and the pilot valve port is closed. After the pressure balance between the pilot valve and the main valve cavity, the valve is closed again.


Technical parameter of ADK11-25 CKD Type Pilot Kick Solenoid Diaphragm Valve:

ModelPort sizeOrifice sizeCV value

Working pressure

Max Fluid temperature

(℃)

Seal materialInsulationCoil power
Min (MPa)Max (MPa)
VAW
AC220VDC24VAC220VDC24V
ADK11-103/8''164.8010680NBRH2020
164.80106130EPDMH2020
164.80106120VITONH2020
ADK11-151/2''164.8010680NBRH2020
164.80106130EPDMH2020
164.80106120VITONH2020
ADK11-203/4''207.6010680NBRH2020
207.60106130EPDMH2020
207.60106120VITONH2020
ADK11-251''2512010680NBRH2032
25120106130EPDMH2032
25120106120VITONH2032

Common specifications of CKD Type ADK11 Series Pilot Kick 2 Way Solenoid Valve:

ItemStandardOptional
Working mediumAir, Low Vacuum, Water, Paraffin, OilHot water
Working pressure differential range (MPa)0 to 1.0 (refer to max. working pressure differential in individual specifications.)
Max. working pressure2 MPa
Withstanding pressure (water)4 MPa
Fluid temperature-10°C to 60°C-10°C to 90°C
Ambient temperature-10°C to 60°C
Heat proof classBH
AtmospherePlace free of corrosive gas and explosive gas
Valve structurePilot kick type poppet, Diaphragm structure
Valve seat leakage1cm³/min or less (air)
Mounting attitudeFree
Body, sealantBronze, nitrile rubber(NBR)Bronze, ethylene propylene diene rubber (EPDM)

Main dimension of ADK11-25G CKD Type Pilot Kick Solenoid Valve NC Normally Closed Type:


Deconstruction diagram of G1'' inch brass body ADK11-25 CKD type 2 port solenoid valve:


Production of ADK11-25A / 25G / 25N CKD Type 2 Port Pilot Kick Solenoid Diaphragm Valve:


More details about CKD Type ADK11-25G / 25A / 25N Pilot Kick Solenoid Diaphragm Valve in below Youtube Video:


Usage notice of ADK11-25A / 25G / 25N CKD Type 2 Port Pilot Kick Diaphragm Solenoid Valve:
1. Check the components before use, whether they are damaged during transportation, and then install and use.


2. When installing, please pay attention to the direction of gas flow and the correct connection.


3. When using, please strictly abide by various technical requirements, such as working voltage, operating frequency, working pressure, and operating temperature; when debugging the whole machine, it is recommended to use manual device to debug, and then power on and debug.


4. Please pay attention to dustproof. It is recommended to install a muffler or a muffler throttle valve at the exhaust port.


5. Install the filter before the valve, and pay attention to eliminate the pipe joints, metal particles, dust and oil in the pipe.


6. When using, install according to the horizontal piping construction, avoid vertical and upside down installation.


The solenoid valve body is made of brass and the coil is pure brass. The diaphragm in the picture is EPDM. Other materials can be customized. The product is mainly used to control the placement of industrial raw materials. It can also be used to regulate other fluids. Working principle: When energized, the electromagnetic force opens the pilot hole, the pressure of the upper chamber drops rapidly, and the pressure difference between the lower part and the lower part is formed around the closing member, pushing the closing member to move upward, the valve is opened; when the power is off, the spring force is used to guide the hole. Closed, the inlet pressure quickly enters the upper chamber through the bypass hole to form a lower low and high pressure difference around the valve closing member, pushing the closing member downward to close the valve.


Welcome to your any question and inquiry!

Quality ADK11-25A / 25G / 25N CKD Type 2 Port Pilot Kick Solenoid Diaphragm Valve G1'' Inch NC Type for sale
Send your message to this supplier
 
*From:
*To: Ningbo Brando Hardware Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0