Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home >

200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08

Categories Pneumatic Solenoid Valve
Brand Name: OEM
Model Number: 4V220-08
Certification: CE、ISO
Place of Origin: China
MOQ: 200 PCS
Price: Negotiation
Payment Terms: T/T, PayPal, Western Union
Supply Ability: 100000pcs per month
Delivery Time: Negotiation
Packaging Details: inner boxes,cartons,pallets
Material: aluminum alloy
Power: Pneumatic
Size: 1/4
Type: Two-position Five-way Solenoid Valve
Standard or nonstandard: Standard
Pressure: Medium Pressure
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08

1/4 inch Inlet and Outlet 200 Series Electromagnetic Pneumatic Valve 4V220-08


4V 200 Series Solenoid Pneumatic Valve,Wiring Form for Lead Wire or Connector type.The inner hole is processed by a special process, the friction resistance is small, the starting air pressure is low, and the service life is long.Can be integrated with the base to save installation space.


Product NameModelTypeMaterialWorking VoltageOperating PressureEffective AreaPower ConsumptionAction FrequencyInsulation Grade
Pneumatic Solenoid Valve4V130C-062 Position 5-WayAluminum Alloy

DC12V DC24V

AC110V AC220V

0.15-0.8MPa12mm²AC:2.5VA DC:2.5W5Cycle per SecondIP65



Troubleshooting:
1. The solenoid valve does not work after being energized.

Check if the power wiring is defective → rewire and connector connection
Check if the power supply voltage is within the ± working range - → adjust the normal position range
Whether the coil is desoldered → re-weld
Short circuit of coil → change coil
Is the working pressure difference inappropriate → adjust the differential pressure → or replace the proportional solenoid valve
Fluid temperature is too high → replace the proportional solenoid valve
There are impurities that cause the main valve core and moving iron core of the solenoid valve to be stuck → cleaning. If there is seal damage, replace the seal and install the filter.
The viscosity of the liquid is too high, the frequency is too high and the life is up to → replace the product


2, the solenoid valve can not be closed

The seal of the main spool or the iron core has been damaged → replace the seal
Whether the fluid temperature and viscosity are too high → replace the solenoid valve of the opposite port
There are impurities entering the solenoid valve to produce the valve core or moving iron core → cleaning
Spring life has reached or deformed → replaced
The orifice balance hole is blocked → timely cleaning
The working frequency is too high or the life is up to → re-elect or update the product


3. Other situations

Internal leak → check if the seal is damaged and the spring is not properly assembled
External leakage → loose connection or seal is broken → tighten the screw or replace the seal
There is noise when energized → the solid parts on the head are loose and tightened. The voltage fluctuation is not within the allowable range and the voltage is adjusted. The iron core suction surface is dirty or uneven, and it is cleaned or replaced in time.


Installation note:

1. When installing, please pay attention to the arrow on the valve body should be consistent with the flow direction of the medium. Do not install in places where there is direct dripping or splashing. The solenoid valve should be installed vertically upwards;
2. The solenoid valve should ensure normal operation within the fluctuation range of 15%-10% of the rated voltage of the power supply;
3. After the solenoid valve is installed, there must be no reverse pressure difference in the pipeline. It needs to be energized several times to make it suitable for use after being warmed up;
4. The solenoid valve should be thoroughly cleaned before installation. The medium to be passed should be free from impurities. Install the filter in front of the valve;
5. When the solenoid valve is faulty or cleaned, a bypass device should be installed to ensure the system continues to operate.