Industrial Switchgear Circuit Breaker Metal Clad KYN61 Series 36 Kv 40.5 Kv

Categories Switchgear Circuit Breaker
Brand Name: ERFA
Model Number: ZN85-40.5
Certification: ISO9001¬2000, CE CCC
Place of Origin: CHINA,XIAN
MOQ: 1PIECE
Price: Negotiated
Payment Terms: T/T, Western Union
Supply Ability: 15000/per year
Delivery Time: 10 days after payment
Packaging Details: export plywood wooden cases
Poles Number: 3
Rated Voltage: 40.5KV
Rated Frequency: 50/60Hz
Specification: IEC: M2-E2-C2
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Industrial Switchgear Circuit Breaker Metal Clad KYN61 Series 36 Kv 40.5 Kv

KYN61-40.5(Z) indoor high voltage vacuum switchgear


Main characteristicss

The switchgear is assembly type.The circuit breaker is floor roll-out.
Adopted new compound insulation vacuum circuit breaker has the features of good interchange ability and easy replacement.
The truck shelf is equipped with lead-screw drive mechanism, which can move truck easily and prevent the mechanism be damaged from faulty operation.

All the operations can be done with the door shut.
All interlocks connecting with the main switch,truck and door of switchgear adopt compulsive mechanical lock and can meet the requirements of "FIVE PREVENTION".
The space of the cable comparment is abundant for the connection of several cables.
The instant earthing switch is used for earthing and short-circuiting of the circuit .
The degree of protection for the enclosure is IP3X.It is IP2X when the door of truck comparment open.It conforms to GB3906-2006,DL404-2007 and refers to IEC-298 standard.



General description

KYN61-40.5(Z) type indoor HV vacuum switchgear(hereinafter called switchgear) is three-phase AC 50Hz indoor power distribution equipment with the rated range voltage of 40.5kV. It is used for power reception and distribution of the power station,substation mining and industrial enterprise for the control,protection and monitor of the circuits, It can be used in the fields where it is operated frequently. It confroms to GB/T11022-2011,GB3906-2006,and DL404-2007 standards.


Applying ambient conditions

Ambient temperature:The max temperature should be +40ºC.The average value in 24 hours should be no more than 35ºC,the min temperature should be -10ºC.
The height above sealevel should be no higher than 1000m.
Relative humidity:daily average relative humidity≤95%,monthly average relative humidity≤90%
Earthquake intensity:not exceed 8 degrees
Saturated vapour pressure:daily average value2.2kPa,monthly average value≤1.8kPa
It should be used in the place where it is free from fire,explosion,serious filth,chemical erosion and violent vibration.



Main technical data of the vacuum switchgear

S.N.NameUnitDate
1rated voltagekV40.5
2rated currentA1250 1600 2000
3rated frequencyHz50
4rated short time withstand currentkA20 25 31.5
5rated peak withstand voltagekA50 63 80
6rated power frequency withstand voltagekV95/1 min
7rated lighting impluse withstand voltagekV185
8rated duration of short circuits4
9the degree of protectionIP3X



Main technical data of the vacuum circuit breaker

S.N.NameUnitDate
1rated voltagekV40.5
2rated frequencyHz50
3rated power frequency withstand voltagekV95/1 min
4rated lighting impluse withstand voltagekV185
5rated currentA1250 1600 2000
6rated short time withstand currentkA20 25 31.5
7rated short circuit withstand currentkA20 25 31.5
8rated peak withstand voltagekA50 63 80
9rated duration of short circuits4
10opening times30≤t≤60
11closing times50≤t≤100
12breaking times of the rated short circuit breaking currentcycles20
13mechanical endurancecycles10000



Main technical data of spring operating mechanism

NameUnitData
rated operate voltageopening coilVDC220/110 AC220/110
closing coil
rated operate currentopening coilA0.96(220V) 1.05(110V)
closing coil
power of energy-stored motorW230
rated voltage of energy-stored motorVDC220/110 AC220/110
distribution for storing energys≤12



The overall dimension of the switchgear
Over dimension(width*depth*height):1400*2800*2600mm


The construction drawing of the switchgear
A. Relay instrument component
B. Bus-bar component
C. Circuit breaker component
D. Cable component

Quality Industrial Switchgear Circuit Breaker Metal Clad KYN61 Series 36 Kv 40.5 Kv for sale