Sign In | Join Free | My frbiz.com |
|
Categories | PVC Electrical Cable |
---|---|
Brand Name: | UNI-CABLES |
Model Number: | H03VV-F |
Certification: | CCC,ISO9001 |
Place of Origin: | CHINA |
MOQ: | 100 Rolls |
Price: | Depends on Quantity |
Supply Ability: | 10000 Rolls per Week |
Packaging Details: | 100 Meters per Roll |
Voltage Rating (Uo/U): | 300/300V |
Temperature Rating: | +5°C to +70°C |
Minimum Bending Radius: | 6x overall diameter |
Core Identification: | 2 core: Blue Brown 3 core: Blue Brown Green/Yellow |
Conductor: | Class 5 flexible copper conductor |
Sheath Colour: | White Black |
Insulation: | PVC (Polyvinyl Chloride) |
Sheath: | PVC (Polyvinyl Chloride) |
H03VV-F PVC Electrical Cable Light Duty Flexible Cable For Connecting
APPLICATION
H03VV-F under the harmonised European Standard, is a light duty flexible cable designed for use in domestic properties, offices and kitchens. It is suitable for connecting devices with a voltage rating of 300V that are subjected to low mechanical stress such as table lamps, radios and office equipment.
CONSTRUCTION
Conductor
Class 5 flexible copper conductor
Insulation
PVC/TI2
Sheath
PVC/TM2
CABLE STANDARDS
BS EN 50525-2-11 (previously BS 6500, CENELEC HD21.5),
VDE 281, BS EN/IEC 60332-1-2
DIMENSIONS
UNIQUE PART NO. | NO. OF CORES | NOMINAL CROSS SECTIONAL AREA | NOMINAL THICKNESS OF INSULATION | NOMINAL THICKNESS OF SHEATH | NOMINAL OVERALL DIAMETER | NOMINAL WEIGHT |
mm² | mm | mm | mm | kg/km | ||
H03VV-F2X0.5 | 2 | 0.5 | 0.5 | 0.6 | 5.0 | 37 |
H03VV-F2X0.75 | 2 | 0.75 | 0.5 | 0.6 | 5.5 | 46 |
H03VV-F3X0.5 | 3 | 0.5 | 0.5 | 0.6 | 5.3 | 44 |
H03VV-F3X0.75 | 3 | 0.75 | 0.5 | 0.6 | 5.8 | 55 |
H03VV-F4X0.5 | 4 | 0.5 | 0.5 | 0.6 | 5.8 | 54 |
Colour Codes
COLOUR | Black | White |
CODE | BK | WH |
CONDUCTORS
Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables
NOMINAL CROSS SECTIONAL AREA mm² | MAXIMUM DIAMETER OF WIRES IN CONDUCTOR mm | MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC |
Plain Wires ohms/km | ||
0.5 | 0.21 | 39 |
0.75 | 0.21 | 26 |
ELECTRICAL CHARACTERISTICS
Current Carrying Capacity and Mass Supportable
NOMINAL CROSS SECTIONAL AREA mm² | CURRENT CARRYING CAPACITY | MAXIMUM MASS SUPPORTABLE BY TWIN FLEXIBLE CORD kg | |
Single-Phase AC Amps | Three-Phase AC Amps | ||
0.5 | 3 | 3 | 2 |
0.75 | 6 | 6 | 3 |
Voltage Drop
NOMINAL CROSS SECTIONAL AREA mm² | DC OR SINGLE-PHASE AC mV/A/m | THREE-PHASE AC mV/A/m |
0.5 | 93 | 80 |
0.75 | 62 | 54 |
![]() |