Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home > Industrial Controls >

ABB Module DSQC332 3HAB8101-2 ABB DSQC332 3HAB81012 Digital I/O Relay DSQC Ship to Worldwide

Categories ABB Module
Brand Name: ABB Module
Model Number: DSQC332 3HAB8101-2
Certification: CO.CQ
Place of Origin: Sweden
MOQ: 1
Price: inquiry
Payment Terms: T/T
Supply Ability: 10 pieces a day
Delivery Time: today
Packaging Details: new and original with factory sealed
Manufacture Year: 2016
Control System: ABB Module System
Application: Nuclear Power Plant
lead time: in stock
description: DSQC332 3HAB8101-2 ABB DSQC332 3HAB81012 Digital I/O Relay DSQC Ship to Worldwide
Weight: 4lbs
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

ABB Module DSQC332 3HAB8101-2 ABB DSQC332 3HAB81012 Digital I/O Relay DSQC Ship to Worldwide

ABB Module DSQC332 3HAB8101-2 ABB DSQC332 3HAB81012 Digital I/O Relay DSQC Ship to Worldwide


Product Description:


Features of the digital inputs/outputs:The 8 digital inputs/outputs are arranged in one group.
The group as a whole is electrically isolated from the rest of the device. The inputs/outputs can be used individually as input, output or re-readable output. If the terminals are used as digital inputs, the input
signal delay can be configured to 7 ms (default) or to 1 ms. The configuration is performed by setting certain bits in the system constant KW 85,01 as follows: If the terminals are used as digital outputs, the output signals "1" are individually monitored by the re-readable input. If the output status is wrong, anoverall error message is generated for the involved output group. The error is displayed by the red LED Ovl. and by error flags of the PLC then. The error could have been caused by overload, shortcircuit
or missing supply voltage UP5/ZP5.



Related Product Recommendation:


DSQC608 3HAC12934-1MAG-XEDRA02 37411-4-0369673
DSQC609 3HAC14178-1MAI32MADDSAB-02C
DSQC609 3HAC14178-1MB21 MB 21DSAI110 57120001-DP
DSQC611 3HAC13389-2MB510 3BSE002540R1DSAI145 5712001-HA
DSQC626A 3HAC026289-001MM21 MM 21DSAO110 57120001-AT
DSQC639 3HAC025097-001MPRC 086349-002DSAO120A 3BSE018293R1
DSQC643 3HACO24488-001MV03 MV 03DSBC110 57310256-E
DSQC652 3HAC025917-001MZ03 MZ 03DSBC111 57310256-K
DSQC662 3HAC026254-001NAIO-01DSBC173 57310001-KH
DSQC664 3HAC030923-001NAOM01DSBC174 3BSE012211R1
DSQC668 3HAC029157-001NGDR-02CDSBC176 3BSE019216R1
DSQC679 3HAC028357 001NISA-03DSCA120 57520001-P
DSQC679 3HAC028357001NTAC-02DSCA125A 57520001-CY
DSQC697 3HAC037084-001NTAI05DSCA160A
DSSB146 48980001-AP/1 DSSB146*BAT2CNTAI06DSCS140 57520001-EV
DSSR122 48990001-NKNTCL01DSDC110B 57310001-FT
DSSR170 48990001-PCNTCL01-ADSDI110AV1 3BSE018295R1
DSTA131 57120001-CVNTCS04DSDI130 57160001-AA
DSTA131 57120001-CVNTDI0-ADSDI131 57160001-GV
DSTA160 57120001-AHNTDI01DSDO115 57160001-NF
DSTA180 57120001-ETNTRO02 NTRO02-ADSDO115A 3BSE018298R1
DSTC170 57520001-BKNTRO02-ADSDO120 57160001-AK
DSTC190 57520001-ERNTRO02-A NTRO02DSDO131 57160001-KX
DSTC454 5751017-FPAB02 P70870-4-0369059 369059A10DSDP170 DSDP 170 57160001-ADF
DSTD 110A 57160001-TZPCU-03DSDX180 3BSE003859R1
DSTD108P 3BSE018333R1PE1364BDSDX451L 5716075-AH
DSTD132 5716001-FXPHARPS32200000DSDX454 5716075-AT
DSTD150A 57160001-UHPHARPS62200000DSMB114 57360001-MG
DSTX120 57160001-MAPHARPSPEP11013DSMB116 5736 0001-EB
ECC 086387-0013BSE012790R1DSMB144 57360001-EL
XV371A3BSE018283R1AI610 3BHT300000R1

Product's Character:


The technical specifications of the inputs are the same with the other digital inputs, but with the following
exception: Caused by the direct electrical connection with the output, the varistor for demagnetization of inductive loads (see figure above) is also in effect at the input. Therefore, the voltage difference between UP5 and the input signal must not be greater than the limit voltage
of the varistor.If the counter is used in the operating modes 1 or 2 (up-counter), the output A 62,00 is only available for the counter. If the output is to use as a normal digital output, it has to
be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").



DCS800-S01-0090-05 Module Drive ABB
DCS800-S01-0125-05 Module Drive ABB
DCS800-S01-0180-05 Module Drive ABB
DCS800-S01-0230-05 Module Drive ABB
DCS800-S01-0290-06 Module Drive ABB
DCS800-S01-0290-07 Module Drive ABB
DCS800-S01-0315-05 Module Drive ABB
DCS800-S01-0405-05 Module Drive ABB
DCS800-S01-0470-05 Module Drive ABB
DCS800-S01-0900-06 Module Drive ABB
DCS800-S01-0900-07 Module Drive ABB
DCS800-S01-1500-06 Module Drive ABB
DCS800-S01-1500-07 Module Drive ABB
DCS800-S01-2050-05 Module Drive ABB
DCS800-S01-2050-06 Module Drive ABB
DCS800-S02-0025-05 Module Drive ABB
DCS800-S02-0050-05 Module Drive ABB
DCS800-S02-0075-05 Module Drive ABB
DCS800-S02-0100-05 Module Drive ABB
DCS800-S02-0140-05 Module Drive ABB

DCS800-S02-0200-05 Module Drive ABB
DCS800-S02-0260-05 Module Drive ABB
DCS800-S02-0290-06 Module Drive ABB
DCS800-S02-0290-07 Module Drive ABB
DCS800-S02-0350-05 Module Drive ABB
DCS800-S02-0450-05 Module Drive ABB
DCS800-S02-0520-05 Module Drive ABB
DCS800-S02-0900-06 Module Drive ABB
DCS800-S02-0900-07 Module Drive ABB
DCS800-S02-1500-06 Module Drive ABB
DCS800-S02-2000-06 Module Drive ABB
DCS800-S02-2000-07 Module Drive ABB
DD 370A GJR2237400R0001, GJR2237400R1 DD370A Diode Module ABB
DD 371a HEIE 420334 R1 DD 371a Module ABB


The use of the product:

1.aluminum smelting machines,

2.energy,

3.transmission and distribution.
Product's advantages:

1. provides integrated control, power, safety,
and information solutions for complete plant-wide control in a scalable,


2. new and original


3.Customer service in 1-4 hours. If there's any question, please contact with our sales.


Our advantages:

1.Improve efficiency


2.Optimize plant operations


3.emission reduction

Frequently Asked Questions:

1. Q: Are the P/N latest?
A: Yes. All P/N are latest and date codes are in 2016 or 2017.


2.Q: What is the capacity of your warehouse?
A: We have 1-2Mil USD safe stocks and 3 warehouses, which located Xiamen, Shenzhen & Hongkong.


3.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !


Send your Inquiry details in the Below, Click "Send" Now!

Contact Information:
Contact:Miya ( manager)

Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )

Product Tags:

advant ocs

  

advant controller 31

  
Quality ABB Module DSQC332 3HAB8101-2 ABB DSQC332 3HAB81012  Digital I/O Relay DSQC Ship to Worldwide for sale
Send your message to this supplier
 
*From:
*To: MOORE AUTOMATION LIMITED
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0