2×6.0mm² (PV1-F / H1Z2Z2-K) (NO.7194104) |
General characteristics: |

|
Appllcation: |
Specifically designed to connect photovoltaic system components
inside and outside buildings and facilities under high mechanical demands and extreme weather
conditions. |
Cable Construction: |
Conductor | |
|
Metarial: | Tinned annealed copper |
Area(mm²) : | 2×6.0 |
Construction(N/mm) : | 84/0.30 |
Conductor(Dia./mm) : | 3.17 |  |
Insulation | 120℃ XLPE |
Standard thickness (mm) : | 0.75 |
Standard diameter (mm) : | 4.67±0.1 |
Jacket | 120℃ XLPE, Black |
Standard thickness (mm) : | 1.05 |
Outer diameter (mm) : | (7.0±0.2)×(14.5±0.2) |
Weight rated | 102.6 |
Making | ZION COMMUNICATION PV1-F / H1Z2Z2-K 2x6.0mm² UV Res DC 1.5KV AC 0.6/1KV SOLAR CABLE |
| | | | | | |
Package: |
BOX (art.code ZC-100-2×6.0mm/ZC-500-2×6.0mm) |
 |
Size: 310x 310x100mm |
PALLET (art.code ZC-100-100-2×6.0mm) |
Size: 1100x1100mm |
Amount of boxes on one pallet: | |
Weight of total pallet: | |
Cable length pallet: | |
|
Electrical properties |
Nominal Voltage: | PV1-F: DC 1.0KV AC 0.6/1.0KV H1Z2Z2-K: DC 1.5KV AC 1.0/1.0KV |
Ambient Temperature: | -40℃~+90℃ |
Max.Temperature at conductor: | +120℃ |
Service life: | >25 years ( -40℃~+90℃) |
Voltage: | 600/1000V |
Temperature: | -40~90℃ |
Conductor resistance (20℃): | 3.39Ω/km |
Insulation resistance (70℃): | ≥1000 MΩ/km |
Withstand voltage(V/5min) | AC6500 |
Speak voltage(V/5min) | AC6500 |
Min bending radius(mm) | 4*D |
|
Main performance parameter of finished cable |
Voltage test of finished cable |
Min.time of dipping in water | ≥1(h) |
Testing voltage (AC) | 6500(V) |
Min.voltage applying time at one time | 5(min) |
Test result | no breakdown |
Sheated surface resistance |
Length of specimen: | 250mm |
Test result | ≥109Ω |
Penetrate the insulation resistance |
Temperature | 20℃ |
Test result | ≥1014Ω |
High temperature stress |
Temperature | 140℃ |
A: with 1.2 Voltage test | A: No breakdown |
B: deep pressure | B: Wall thickness 50% |
Damp-heat test |
Temperature | 90℃ |
Humidity | 0.85 |
Aging before and after the tenslle strength of Change | ≤30% |
Aging before and after the elongation at break of Change | ≤-30% |
|
Acid-alkali Resistance |
Min.time of dipping in | 168h |
Aging before and after the tensile strength of Change | ≤-30% |
Elongation | ≥100 |
Low-temperature bending |
Temperature | -40℃ |
Time | 16h |
Test result | No crack |
Ozone resistance |
Ozeone concentration % | (200±50)x10-6 |
Time | 72h |
Test result | No crack |
Heat schrinkable jacket test |
Test result | ≤2% |
Flame retardant-Vertical burn | |
Flxture on the lower edge from the starting point and carbonization | ≥50mm |
Burning fuel downward from the lower edge of bottom fixture | ≤540mm |
Halogen content of non-metallic materials |
Test result | |
Chlorine and bromine content | HCL≤0.5HBr≤0.5% |
Fluoride content | F≤0.1% |
The inner layer of insulation and sheath of the mechanical
properties |
Test result | |
Aging before tensile strength | 8.0N/mm² |
Aging before elongation | 1.25 |
Aging before and after the tensile strength of change | -30% |
Aging before and after the elongation at break of change | -30% |
Hot extension |
Temperature | 200℃ |
Test result-The inner layer of insulation and sheath | |
Elongation under load | ≤100% |
Elongation after unloading | ≤25% |