Brand Name: EuroKlimat
Model Number: EKDM
Certification: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Place of Origin: China
MOQ: 1
Price: negotiation
Payment Terms: L/C, T/T
Supply Ability: 5,000pcs per month
Delivery Time: 15 working days after received your payment
Packaging Details: Plywood
Product Name: clean room ( AHU ) return air handling units
Installation: Ceiling/floor installation
Cooling Capacity(kW): 25-300
Heating Capacity(kW): 28-330
Air Flow(m3/h): 5000-60000
Aluminum Fins: Shutter-type hyperbolic and hydrophilic fins
Test Pressure (Mpa): 3.3
Coils rows: 4/6
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Double Skin Clean Room AHU Return Air Handling Units Indoor Installation

EK keeps looking for valuable distributors and partners around international markets…


Double skin clean room ( AHU ) return air handling units indoor installation


EKDM air flow range is from 1000m3/h to 400000m3/h. Available functional sections include fresh/return air mixing section, cooling section, heating section, primary/medium/high efficiency filter section, electric heating section, humidifying section, sound attenuation section, heat recovery section, secondary air-return section, fan section, air diffuser section etc. Different combinations can meet different air handling requirements.


• The surface of the unit is made of quality color steel, which can resist corrosion, scratch and ultraviolet radiation.


• Internal panels are made of steel plates galvanized with aluminum and zinc, with an assured service life of more than 15 years. All panels feature end-to-end joints and smooth surfaces, without any bur or corroded point.


• The internal panels feature reinforced design, which is strong enough to support the largest air handling unit.


• The unit panel has two thicknesses, namely 30mm and 50mm.Inside the panel, hermetically foamed polyurethane (no fluorine) with a density of 48kg/m3 is used as the heat- insulating material. The heat conductivity factor is less than 0.02W/m°C.


• Each functional section of the unit is equipped with a steel trough base, thus ensuring it is well supported, easy to transport and assemble. The overall robustness of the unit meets the standard of CEN2.


Filter as below :


ChinaPrimary efficiency 5μmMedium efficiency 1μmMedium high efficiency 1μmSub-high efficiency 0.5μmHigh efficiency 0.5μm
GB/T1429550% > Efficiency > 20%70% > Efficiency > 20%99% > Efficiency >
70%
99.9% > Efficiency > 95%Efficiency > 99.99%
USA ASHRAEC1

C2~

C4

L5L6L7L8M9M10M11M12M13M14H12-H16VH17VH18VH19VH20
EuropeNew
standard
G1G2G3G4F5F6F7F8F9H10H11H12H13H14

V15,

V17

efficiency65%80%80-90%> 90%40%60%80%90%85%95%99%99.9%99.995%

99.

995%

99.

9995%

Old
speci-fication
EU1EU2EU3EU4EU5EU6EU7EU8EU9EU10EU11EU12EU13EU14

Specifciations


Model
EKDM
Rated air flow m3/hWindward area of coil (m2)Air flow (m3/h)Diameter of fan impeller mmFan performance
2.252.502.753.00Max. total pressure of fan PaMax. motor power kW
m/sm/sm/sm/s
30620000.23186320702277248416013002.2
40630000.34275430603366367220013003
40740000.41332136904059442822515003
40850000.48388843204752518425018005.5
50860000.65526558506435702028018007.5
60770000.69558962106831745228018007.5
60880000.81656172908019874831518007.5
51190000.9476148460930610152315180011
610100001.05850594501039511340355200011
611120001.179477105301158312636400200015
712150001.5512555139501534516740450200015
812180001.8114661162901791919548500200018.5
813200001.9816038178201960221384500200018.5
915250002.6621546239402633428728560200022
1015300002.9924219269102960132292630200030
1313350003.4027540306003366036720630200030
1315400003.9932319359103950143092710200030
1515450004.6537665418504603550220800200037
1417500004.9540095445504900553460800200045
1520600006.3651516572406296468688900200045
1720700007.2758887654307197378516900200055
1722800008.05652057245079695869401000200075
1626900009.01729818109089199973081000200075
182610000010.21827019189010107911026811202000110
1852200000020.421654021837802021582205361120x22000110x2
3652400000040.843308043675604043164410721120x42000110x4

Note:
■ This table only lists some typical models among many models for quick model selection.
■ Total fan pressures listed above are tested on standard fans with rated air flow.
■ External residual pressure = Total fan pressure - Internal resistance. For internal resistance of EKDM units.

Quality Double Skin Clean Room AHU Return Air Handling Units Indoor Installation for sale
Send your message to this supplier
 
*From:
*To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0