HCTL300KA High Frequency Flexible Current Probe High Voltage & Ultra High Current Measurement for EHV Power Systems

Categories Electronics Test Instruments
Brand Name: MEASTEK
Model Number: HCTL300KA
MOQ: 1
Payment Terms: T/T,Western Union,MoneyGram
Delivery Time: 5-8 work days
Sensitivity (mV/A): 0.02
Current (KA): 300
Maximum noise (mV Vpp): 3
Attenuation characteristics (%/ms): 0.01
Low frequency bandwidth -3dB(Hz): 0.01
High frequency bandwidth -3dB(MHz): 10
Typical accuracy: 1%
Insulation voltage value: 10KV
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

HCTL300KA High Frequency Flexible Current Probe High Voltage & Ultra High Current Measurement for EHV Power Systems

MEASTEK HCTL300KA High Frequency Flexible Current Probe High Voltage & Ultra High Current Measurement for EHV Power Systems


1.High-frequency detection capability: 10MHz bandwidth can detect high-frequency sinusoidal current waveforms. In the current monitoring of ultra-high voltage transmission lines, it can effectively capture high-frequency interference current signals and provide data support for ensuring the stability of power transmission.


2. Accurate measurement of tiny currents: 0.02mV/A sensitivity, 1% typical accuracy, can measure tiny current changes, suitable for monitoring weak current signals of ultra-high voltage power equipment, and timely discover potential equipment failures.


3. Ultra-high withstand voltage characteristics: 10KV insulation withstand voltage, suitable for current measurement of ultra-high voltage power systems with large current and ultra-high voltage, can work safely and reliably in ultra-high voltage environments, and ensure the safety of the measurement process.


4. Flexible installation advantages: The outer diameter of the probe ring is 8mm, soft and freely pluggable. In the distributed current monitoring scenario, it is convenient to install in ultra-high voltage poles and towers, etc., which is convenient for comprehensive current monitoring of ultra-high voltage lines.


5. Convenient connection and power supply: USB power supply, easy to use, standard BNC output interface is convenient for connecting professional measurement equipment, realizing ultra-high voltage power system current data collection and analysis, and providing strong support for power operation and maintenance.


Specifications

ModelHCTL300KA
Sensitivity (mV/A)0.02
PeakCurrent (KA)300

dI/dt(KA/μs)

40
Maximum noise (mV Vpp)3
Attenuation characteristics(%/ms)0.01
Low frequency bandwidth -3dB(Hz)0.01
High frequency bandwidth -3dB(MHz)10
Typical accuracy

1%

Insulation voltage value

10KV


HCT(S)XXXXA Series Other Technical Parameters

Maximum output voltage

6Vpk

Terminal load

≥100kΩ

Power supply modeUSB 5V (standard adapter)
Operating temperature rangeIntegrator

0℃ - 50℃

Probe ring

0℃ - 100℃

Storage temperature range

-40℃~80℃


Product Description

(Take HCTS0120A as an example)


1) Input interface: current probe test signal input terminal.
2) Output interface: current probe integrator signal output terminal.
3) USB 5V power supply interface: standard USB (type B) interface. (USB power supply cable and power adapter are standard)

4) Test connection diagram.


Mechanical specifications

ModelHCTSXXXXA
Typical value of flexible probe circumference (customizable)

80mm

Typical value of induction ring body diameter

1.6mm

Typical value of flexible probe diameter (customizable)

25mm

Induction loop connection cable length1 M (customizable)
BNC connection cable length1 M or 2 M, 1 M is Standard

Integrator body dimensions

(including BN port dimensions)

About 110(L)*47(W)*30(H)mm
USB cable (AM-BM)About 1.8m
USB output adapterAbout 59mm*30mm*20mm
Probe weightAbout 150g
Box weight (including probe)About 960g


Care And Maintenance

1) Keep the probe clean and dry.
2) If cleaning is required, wipe with a soft dry cloth. Do not use chemical cleaning agents.
3) When the probe is not in use, please put it in the packaging provided and place it in a cool, clean and dry place.
4) When transporting the probe, be sure to put it in the packaging provided by our company to prevent shock.
5) Do not pull the input and output lines hard to avoid excessive twisting, bending or knotting.


Packing List

NameQuantity
Current probe integrator1 piece
Current probe flexible induction coil1 piece
USB output adapter (5V/1A)1 piece
USB power cable1 piece
BNC output cable1 piece
Electronic manual1 serving


Quality HCTL300KA High Frequency Flexible Current Probe High Voltage & Ultra High Current Measurement for EHV Power Systems for sale
Send your message to this supplier
 
*From: