Sign In | Join Free | My frbiz.com |
|
Categories | Laser Range Finder Module |
---|---|
Brand Name: | FOVA |
Model Number: | YZT-CJ-0810A |
Place of Origin: | SHENZHEN |
Certification: | CE;FCC |
MOQ: | 10PCS |
Packaging Details: | 27mmx22mmx17mm |
Delivery Time: | 7-15 working day |
Payment Terms: | T/T |
Supply Ability: | 100000Pcs/Month |
Beam Divergence: | Less Than 1 Mrad |
Resolution: | 0.1 Meter |
Interface: | RS232/RS422 |
Power: | Low Power Consumption |
Weight: | ≤120g |
Frequency: | 1 Hz |
Warranty Years: | 1 Year |
Application: | Surveying, Mapping, Geodesy |
Advantage: | Eye-safe |
Dimensions: | 45 x 25 x 12 mm |
Laser Type: | Class 2, 635nm |
Data Output: | RS-232 or USB |
Battery Life: | Up to 10,000 measurements |
Minimum Range: | ≤50m |
Software: | Trimble RealWorks |
Model: | Laser Ranging Module |
Communication Interface: | UART, I2C |
Highlight: | High Precision |
Response Time: | 10ms |
Communication Distance: | Up to 100m |
Measurement Speed: | Up to 20,000 measurements per second |
Measurement Range: | 0.03-40m |
Ip Rating: | IP54 |
Company Info. |
Shenzhen FOVA Technology Co.,Ltd |
Verified Supplier |
View Contact Details |
Product List |
YZT-CJ-0810A
Laser Range Finder Module
Technical Specification
YZT-CJ-0810A laser ranging module is the eye safety laser ranging module in the photoelectric system, which can detect the target distance and transmit the measured distance to the host computer through serial communication.
The YZT-CJ-0810A laser ranging module consists of a laser, a transmitting optical system, a receiving optical system and a control circuit. The main performance is as follows:
2.1 Operating range
Visibility under visible conditions is not less than 12km, diffuse reflectance ≥0.3, humidity ≤80%, the vehicle (2.3m×2.3m target) ranging distance ≥8km.
2.2 Features
The main functions of the laser ranging module are:
a) single ranging and continuous ranging;
b) Range strobe, front and rear target indication;
c) Self-inspection function.
2.3 Performance
2.4 Interface
Communication interface: RS422, 115200bps
Electrical interface: The interface model is Molex connector 51021-0800. The interface definition is described in the following table.
8P socket wiring definition | |||
No. | Definition | Wire color | Remarks |
1 | RS422 RX+ | Brown | RS422 receive + |
2 | RS422 RX- | Blue | RS422 receive - |
3 | RS422 TX- | Yellow | RS422 send - |
4 | RS422 TX+ | Purple | RS422 send + |
5 | GND | White | Communication interface |
6 | +12V | Red | Power supply |
7 | GND | Black | Power supply earthing |
8 | Reserved | Empty | Reserved |
3. Precautions for use
![]() |