Categories AC DC Open Frame Power Supply
Brand Name: MORNSUN
Model Number: LOF750-20Bxx Series
Certification: CE/UL/CB
Place of Origin: China
MOQ: 100PCS
Price: Negotiated
Payment Terms: T/T
Supply Ability: 500Kpcs/month
Delivery Time: Negotiated
Packaging Details: Carton packed
Product Name: 750W AC DC Open Frame with PFC function power supply
Input voltage: 85-264VAC
Output Voltage: single Output
Input Frequency: 47~63HZ
MTBF: MIL-HDBK-217F@25℃ >300,000 h
Dimension: 127.0mm × 76.2mm × 43.0 mm
Weight: 625g (Typ.)
Cooling Method*: Air cooling (250W) / 25CFM(400W/450W)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

750W PFC SMPS AC DC Open Frame Power Supply Single Output For BF Medical Equipment

750W AC DC Open Frame Switching Power Supply with PFC function single output


Descriptions


LOF750-20Bx series is one of Mornsun’s AC-DC miniaturize open frame power supply and suitable for all kinds of BF type(be accessible to patients) medical system equipment.It features universal AC input and at the same time accepts DC input voltage,cost-effective,low no load power consumption,high efficiency,high reliability and double or reinforced insulation.These converters offer excellent EMC performance and meet IEC/EN/UL62368,GB4943,IEC/EN60335,IEC/EN61558,IEC/EN/ES60601-1standards and they are widely used in areas of Medical, LED, street light control,electricity,security,telecommunications LED, smart home etc.


Features

  • Universal 90 - 264VAC or 127 - 370VDC input voltage
  • Compact size 5”× 3”
  • Operating ambient temperature range: -40C to +70C
  • Built-in active PFC function
  • Operating altitude up to 5000m
  • Output short circuit, over-current, over-voltage,
  • over-temperature protection
  • 450W with air cooling, 750W with 25CFM
  • 5VDC standby output, 5VDC fan supply
  • PG signal and remote sensing function
  • Design to meet medical approvals and be suitable for
  • BF type applications
  • The base plate with conformal coating
  • Safety according to IEC/EN62368, ES/EN60601, EN60335,GB4943

Specifications


Selection Guide
CertificationPart No.Cooling Method

Input Voltage

Range

(V)

Output

Power

(W)*

Nominal Output

Voltage and Current (Vo/Io)

Output

Adjustable

Range ADJ (V)

Efficiency at

230VAC (%)

Typ. *

Capacitive

Load

(µF) Max.


--

LOF750-20B12Air coolingFull voltage range399.612V/33.31 1.4- 12.6925000
25CFM699.612V/58.3
LOF750-20B15Air coolingFull voltage range400.515V/26.714.25- 15.75925000
25CFM700.515V/46.7

LOF750-20B24

Air cooling1 15VAC400.824V/ 16.7

22.8-25.2


94


3000

230VAC451.224V/ 18.8
25CFMFull voltage range748.824V/31.2

LOF750-20B27

Air cooling1 15VAC399.627V/ 14.8

25.65-28.35


94


3000

230VAC450.927V/ 16.7
25CFMFull voltage range750.627V/27.8

LOF750-20B36

Air cooling1 15VAC399.636V/ 1 1. 1

34.2-37.8


94.5


2000

230VAC450.036V/ 12.5
25CFMFull voltage range748.836V/20.8

LOF750-20B48

Air cooling1 15VAC398.448V/8.3

45.6-50.4


95


2000

230VAC451.248V/9.4
25CFMFull voltage range748.848V/ 15.6

LOF750-20B54

Air cooling1 15VAC399.654V/7.4

51.3-56.7


95


1000

230VAC449.854V/8.33
25CFMFull voltage range750.054V/ 13.89
Notes: 1.*Under any conditions, the total power of the product should not exceed the rated power. When the output voltage is increased, the total output power cannot exceed the rated output power, when the output voltage is decreased, the output current cannot exceed the rated output current; 2.*When measuring the full load efficiency, the fan should be connected to an external power supply. Fan loss is not included in the input power.

Input Specifications
ItemOperating ConditionsMin.Typ.Max.Unit
Input Voltage RangeAC input90--264VAC
DC input127--370VDC
Input Frequency47--63Hz
Input Current1 15VAC----8

A

230VAC----4
Inrush Current1 15VACCold start--50--
230VAC--80--
Power Factor1 15VACFull load0.98------
230VAC0.95----
Leakage Current264VACContact leakage current<0. 1mA
Earth leakage current<0.5mA
Hot PlugUnavailable
Output Specifications*
ItemOperating ConditionsMin.Typ.Max.Unit

Output Voltage

Accuracy*

Full load12V/ 15V/24V/27V--±2.0--

%

36V/48V/54V--± 1.0--
Line RegulationRated load--±0.5--
Load Regulation0%- 100% load--± 1.0--
Ripple & Noise*20MHz band width (peak-to-peak value)----200 V

Temperature

Coefficient

--±0.03--%/C
Minimum Load0----%
Hold-up Time25C, 115VAC/230VAC10----ms

Stand-by Power

Consumption

Room temperature, 230VAC input

(PS_ON Low and 5Vsb without load (including fan))

----0.5W
Short Circuit Protection

Recovery time <5s after the short

circuit disappear

Hiccup, continuous, self-recover

Over-current

Protection

≥105%Io, hiccup, self-recover

Over-voltage

Protection

12V≤15.6V

Output voltage turn off, re-power on for recover

15V≤19.5V
24V≤31.2V
27V≤35. 1V
36V≤46.8V
48V≤60.0V
54V≤64.0V

Over-temperature

Protection

Protection when over-temperature, recover automatically after the temperature drops
Fan Power *The 5Vsb serves as the standby power supply and also supplies power to the fan, the maximum output current of the fan and 5Vsb is 2A
PS_ON Input Signal*Power onPS_ON High2--5V
Power offPS_ON Low0--0.6

PG Signal*

Power on

The PG signal goes high

with 10ms to 500ms delay

after power set up

10

--

500

ms

Power off/Power fail

The TTL signal goes low at

least 1ms before output

below 90% of rated value

1

--


--

High levelHigh2--6V
Low levelLow0--0.6
General Specifications
ItemOperating ConditionsMin.Typ.Max.Unit

Isolation

Test

Input - output

Electric strength test for 1min,

leakage current <10mA

4000----

VAC

Input - 2000----
Output - 1500----

Insulation

Resistanc

e

Input - output

Environment temperature: 25±5C

Relative humidity: <95%RH, non-condensing

Testing voltage: 500VDC

100----

MQ

Input - 100----
Output - 100----

Isolation

level

Input - output2 × MOPP
Input - 1 × MOPP
Output - 1 × MOPP
Operating Temperature-40--+70C
Storage Temperature-40--+85
Storage HumidityNon-condensing10--95%RH
Operating Humidity20--90

Power Derating


Operating temperature derating

25CFM12V/ 15V(700W)+50C to +70C2.0----%/C

24V/27V/36V/

48V/54V(750W)

+50C to +70C2.0----

Air cooling

12V/ 15V(400W)+45C to +70C7.9----

W/C

24V/27V/ 36V/48V/

54V

(450W)

90- 175VAC

(400W)

+45C to +70C7.0----

176-264VAC

(450W)

+45C to +70C9.0----

Input voltage

derating

90VAC - 1 15VAC0.8----%/VAC
127VDC - 162VDC0.57----%/VDC
Safety Standard

Design refer to IEC/EN62368- 1, ES/EN60601- 1, EN60335- 1,

GB4943. 1

Safety ClassCLASS I/CLASS II
MTBFMIL-HDBK-217F@25C>200,000 h
Mechanical Specifications
Case MaterialOpen frame
Dimension127.0mm × 76.2mm × 43.0 mm
Weight625g (Typ.)
Cooling Method*Air cooling(400W/450W) / 25CFM (700W/750W)
Note: *Cooling method and power derating refer to typical characteristic curves.



Quality 750W PFC SMPS AC DC Open Frame Power Supply Single Output For BF Medical Equipment for sale
Send your message to this supplier
 
*From:
*To: KHC Power Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0